Line 749: |
Line 749: |
| =====Outputs===== | | =====Outputs===== |
| Contains all the settings related to the output x. | | Contains all the settings related to the output x. |
| | | [[NVGate_Output_Signals#Output_chanel_settings|Read output page for details.]] |
| * '''Label''': the name of this Output (by default Output n, with 1 <nowiki><</nowiki>= n <nowiki><</nowiki>= 2). The label of each output is used in the result name and in all connection tools.
| |
| * '''Source''': the input signal of the output (NONE by default). The input signal can be any dynamic input of the Front-end (in the On-line mode) or any signal generated by the output signals resource (in the On-line mode) or any track of the Player (recorded from inputs).
| |
| * '''Applied ''''''filter''': the filter applied to this output. The list of filters applicable to the outputs is defined in the Filter module, by choosing Apply to= All.
| |
| * '''Clipping''': the amplitude limitation of the output signal (from 1 mV to 10 V).
| |
| * '''Gain''': This setting can be displayed in dB. It is the gain applied to the output signal.
| |
| * '''Impedance''':
| |
| | |
| {|border="2" cellspacing="0" cellpadding="4" width="77%" align="center"
| |
| |'''Impedance'''
| |
| |'''Description'''
| |
| | |
| |-
| |
| |GND
| |
| |The output is connected to the ground.
| |
| | |
| |-
| |
| |50 Ohms
| |
| |The output impedance is equal to 50 Ohms. | |
| | |
| |-
| |
| |600 Ohms<ref>Only available for OR38 & OR36. For phone lines connections use.</ref>
| |
| |The output impedance is equal to 600 Ohms.
| |
| | |
| |}<br clear="all">
| |
| | |
| * '''Synchronization''':
| |
| | |
| {|border="2" cellspacing="0" cellpadding="4" width="92%" align="center"
| |
| |'''Synchronization'''
| |
| |'''Description'''
| |
| | |
| |-
| |
| |Free run
| |
| |The output delivers a signal as soon as there is a source connected.
| |
| | |
| |-
| |
| |Linked to run
| |
| |The output is activated only after the first run action.
| |
| | |
| |}<br clear="all">
| |
| | |
| * '''Transition control''': On / Off. If the value of this setting is "On" the ''Output settings/transition time'' is applied when this output is activated or disabled.
| |
|
| |
|
| =====Aux. Output===== | | =====Aux. Output===== |