Line 171: |
Line 171: |
| ====Marker group==== | | ====Marker group==== |
| [[Image:Reports_Tools_Ribbons_26.png|framed|none]] | | [[Image:Reports_Tools_Ribbons_26.png|framed|none]] |
|
| |
|
| |
| Features a complete set of real-time markers that help identifying typical signature and points of exception in both time and spectral graphs. | | Features a complete set of real-time markers that help identifying typical signature and points of exception in both time and spectral graphs. |
| | See [[NVGate_Marker|Marker page]] for more info. |
|
| |
|
| The marker group allows selecting and positioning the chosen marker.
| |
|
| |
| .
| |
|
| |
| The first button corresponds to the marker to be added. It is a multi-action button that gathers all marker type in its list.
| |
|
| |
| *
| |
| [[Image:Reports_Tools_Ribbons_457.png|framed|none]]
| |
| Free marker: Switch the cursor to deposit a free marker in the click location. The free marker can be positioned everywhere to add a legend in a spectra, profile, 1/n octave and waterfall section.
| |
| ''See chapter 2 –Display - § Marker/free marker for details''
| |
|
| |
| *
| |
| [[Image:Reports_Tools_Ribbons_458.png|framed|none]]
| |
| Harmonic marker: Switch the cursor to deposit a set of harmonic in the click location. The harmonic marker can be positioned everywhere in a spectra and waterfall X/Y sections. ''See chapter 2 –Display - § Marker/harmonic marker for details''
| |
| *
| |
| [[Image:Reports_Tools_Ribbons_459.png|framed|none]]
| |
| Peaks marker: Switch the cursor to add a set of peak detection markers in the clicked graph. The peak marker detects automatically the peaks in the spectra and waterfall X/Y sections. ''See chapter 2 –Display - § Marker/peaks marker for details''
| |
| *
| |
| [[Image:Reports_Tools_Ribbons_460.png|framed|none]]
| |
| Max marker: Switch the cursor to add a set of maximum detection markers in the clicked graph. The max marker detects automatically the maximum in the spectra and waterfall X/Y sections. ''See chapter 2 –Display - § Marker/Max marker for details''
| |
| *
| |
| [[Image:Reports_Tools_Ribbons_461.png|framed|none]]
| |
| Side band marker: Switch the cursor to add a side band marker at the clicked location. The Sideband marker can be positioned everywhere in a spectra and waterfall X/Y sections. ''See chapter 2 –Display - § Marker/Sideband marker for details''
| |
| *
| |
| [[Image:Reports_Tools_Ribbons_462.png|framed|none]]
| |
| Power band marker: Switch the cursor to add a power band marker at the clicked location. The power-band marker can be positioned everywhere in a spectra and waterfall X/Y sections. It extracts the RMS power in the selected band taking in account the equivalent bandwidth of the weighting window. ''See chapter 2 –Display - § Marker/Power band marker for details''
| |
| *
| |
| [[Image:Reports_Tools_Ribbons_463.png|framed|none]]
| |
| 1/n Octave data marker: Switch the cursor to add a 1/n octave data marker at the clicked graphs. The 1/n octave data marker can be positioned in CPB spectra and waterfall X/Y sections of the same type. It extracts the list of the band levels in db or linear units into the infotrace. ''See chapter 2 –Display - § Marker/Octave marker for details''
| |
| *
| |
| [[Image:Reports_Tools_Ribbons_464.png|framed|none]]
| |
| Kinematic marker: Switch the cursor to deposit a set of harmonic in the click location. The harmonic marker can be positioned everywhere in a spectra and waterfall X/Y sections. ''See chapter 2 –Display - § Marker/Octave marker for details''
| |
| *
| |
| [[Image:Reports_Tools_Ribbons_465.png|framed|none]]
| |
| Period marker: Switch the cursor to add a periodic marks at the clicked location. The period marker can be positioned trigger blocks. Operates like an harmonic marker but in the time domain.'' See chapter 2 –Display - § Marker/Kinematic marker for details''
| |
| *
| |
| [[Image:Reports_Tools_Ribbons_466.png|framed|none]]
| |
| Record marker (CTRL<nowiki>+</nowiki>M)
| |
| Using this shortcut while the analyzer is recording, add record marker to the signal. If there is a recording window, the maker is displayed. During the recording, a comment can be added to the record marker, via the properties dialog box.
| |
|
| |
| The record marker is available from the ''Measurement\Control'' group. ''See Measurement tab§ in this document.''
| |
|
| |
| The rest of the group is dedicated to the marker adjustments:
| |
|
| |
| *
| |
| [[Image:Reports_Tools_Ribbons_467.png|framed|none]]
| |
| Marker mode: Switch between the marker mode (the cursor controls the marker) and the last used cursor mode. ''See this chapter (6) - §Tabs/ Measurement tab/graph group for details''
| |
| *
| |
| [[Image:Reports_Tools_Ribbons_468.png|framed|none]]
| |
| Move marker: Moves the selected marker of the active window by one step of spectra resolution to the left or right
| |
| *
| |
| [[Image:Reports_Tools_Ribbons_469.png|framed|none]]
| |
| Move marker by 1/32<sup>nd</sup> of step: Moves the selected marker of the active window by a 1/32<sup>nd</sup> of spectra resolution to the left or right. Allowed only if the marker is located in the vicinity (<nowiki>+</nowiki>/- 1 step) of a peak and the X& Y interpolation are enabled
| |
| ====3D group==== | | ====3D group==== |
| This group provides general purpose tools about the Waterfall 3D graphs. | | This group provides general purpose tools about the Waterfall 3D graphs. |