NVGate Ribbons: Acquisition

From OROS Wiki
Jump to navigation Jump to search

Inputs group

The inputs group allows dispatching the front-end channels to the analyzer's plug-in and setting up the front-end. This group is visible in Online mode only.

 

  Connect Inputs: Allow dispatching the front-end inputs (all type) to the analysis plug-ins.
  Inputs: Allow modifying the dynamic input properties. Available when at least one input is active.
  Parametrics: Allow modifying the parametric input (DC) properties. Available when at least one DC input is active.
  External syncs: Allow modifying the digital trigger inputs properties. Available when at least one Ext synch input is active.
  Autorange (CTRL+SHIFT+A): Control and start the auto-ranging procedure. See Chapter 1 ASB § Front-end/Auto-range for details.
  Bridge auto-zero: Balance the inputs connected through the Wheatstone bridge Xpod. See Chapter 1 ASB - § front-end/inputs settings for details.


Player group

This group is visible in Post-analysis mode.

 

  Connect tracks: This button allows dispatching the signal tracks (all types) to the analysis plug-ins.
  Record number: Define the record number (i.e. a section in the file defined during the acquisition) to be post-processed.
  Player settings: Give a direct access to the Player settings
  Playback mode: Allows choosing between a continuous and a step/step post-process.
  • Continuous: the signal analyses are processed as fast as possible between the start and stop offset.
  • Time step: the signal analyses are processed step by step. The step duration is defined by the Step setting (see hereafter). Each new step is manually (or automated by a macro) triggered through the Step setting (see hereafter).
  Step: Defines the time duration of the playback step for the "Time step" analysis mode. The player switches to "pause" every "time step" second.
  Pause/Cont.: Enables to perform the post-analysis up to the next step.


Transducers calibration

Enables to calibrate the sensors. This group is active only in connected mode.

 

  Calibration: Open the calibration procedure tool.
  Detect TEDS: Start the sequence for detecting transducers (or missing one) equipped with an electronic datasheet inside (TEDS: Transducer Electronic Data Sheet) connected to the front end.


See transducer and sensor page for details.

Virtual Inputs group

This group is grayed out if the Virtual Inputs option is not available with the user's licenses or if no input/track is connected to this plug-in.

 

  Dynamic: Enables to copy or move Projects / Measurements / Models from a specified source to the current Projects database.
  Parametric: Enables to copy or move Projects / Measurements / Models from a specified source to the current Projects database.


Tachometers group

 

  Select:Enables to copy or move Projects / Measurements / Models from the current Projects database to a specified target.
  Inputs:
  Ext. Sync:
  Fractional:
  Profile:
  Resolution:
  Combined:


Events group

 

  Associate to:
  Edge: Enables to copy or move Projects / Measurements / Models from the current Projects database to a specified target.
  Level:
  Periodic:
  RPM:
  Delta RPM:
  Combined:


Filters group

 

  Apply to: Enables to copy or move Projects / Measurements / Models from a specified source to the current Projects database.
  High/Low pass:
  Pass/Stop band:
  Integrator:
  Differentiator:


Outputs group

 

  Signals: Enables to copy or move Projects / Measurements / Models from a specified source to the current Projects database.
  Sine:
  Multi-sine:
  Swept-sine:
  Chirp:
  Random noise:
  Output settings: