NVGate Ribbons: Acquisition

From OROS Wiki
Jump to navigation Jump to search

Inputs group

Player group

This group is visible in Post-analysis mode.

 

  Connect tracks: This button allows dispatching the signal tracks (all types) to the analysis plug-ins.
  Record number: Define the record number (i.e. a section in the file defined during the acquisition) to be post-processed.
  Player settings: Give a direct access to the Player settings
  Playback mode: Allows choosing between a continuous and a step/step post-process.
  • Continuous: the signal analyses are processed as fast as possible between the start and stop offset.
  • Time step: the signal analyses are processed step by step. The step duration is defined by the Step setting (see hereafter). Each new step is manually (or automated by a macro) triggered through the Step setting (see hereafter).
  Step: Defines the time duration of the playback step for the "Time step" analysis mode. The player switches to "pause" every "time step" second.
  Pause/Cont.: Enables to perform the post-analysis up to the next step.


Transducers calibration

 

  Calibration: Enables to copy or move Projects / Measurements / Models from a specified source to the current Projects database.
  Detect TEDS: Enables to copy or move Projects / Measurements / Models from a specified source to the current Projects database.


Virtual Inputs group

 

  Dynamic: Enables to copy or move Projects / Measurements / Models from a specified source to the current Projects database.
  Parametric: Enables to copy or move Projects / Measurements / Models from a specified source to the current Projects database.


Tachometers group

 

  Select:Enables to copy or move Projects / Measurements / Models from the current Projects database to a specified target.
  Inputs:
  Ext. Sync:
  Fractional:
  Profile:
  Resolution:
  Combined:


Events group

 

  Associate to:
  Edge: Enables to copy or move Projects / Measurements / Models from the current Projects database to a specified target.
  Level:
  Periodic:
  RPM:
  Delta RPM:
  Combined:


Filters group

 

  Apply to: Enables to copy or move Projects / Measurements / Models from a specified source to the current Projects database.
  High/Low pass:
  Pass/Stop band:
  Integrator:
  Differentiator:


Outputs group

 

  Signals: Enables to copy or move Projects / Measurements / Models from a specified source to the current Projects database.
  Sine:
  Multi-sine:
  Swept-sine:
  Chirp:
  Random noise:
  Output settings: