NVGate 2021: Release note
OROS always strives to be closer to its users and is carefully listening to needs and requests. This is why OROS is regularly releasing new version. Customers under contract automatically benefit from each release.
The NVGate® 2021 mlajor version is available from january 2021. This release of the OROS 3-Series analyzer’s software platform brings additional functionalities and brings significative performance improvements.
This release note describes the content of version 12.00, with operating details.
Compatibility: NVGate V12.00 is compatible with all OROS instruments that have not been discontinued. Depending on the hardware options and version, some instrument features may or may not be available.
Filter no limitation
Filter order
High pass and low pass
Butterworth - Chebyshev band pass - Chebyshev Stop-band ripple
Octave overall no limitation
Application
global level with filter
remove noise from spectrum
Listen signal with filter
Kinematik marker
kinematik marker follow FFT Tachometer
Database include on install
Dirct access to database
Documentation
All the documentation and help have been completely renew. We have put an online wiki-based documentation with video, mnual, application note, download.
This page is in free access and can be consult here https://wiki.oros.com/wiki/index.php/Home
Wiki
If you are connected to Internet Now NVGate the following button will bring you to the NVGate wiki knowledge page.
https://wiki.oros.com/wiki/index.php/NVGate
- Help menu.png Help from the menue File/help
Video
DC simulated
The DC simulated allow you to inject up to 32 external DC channels in NVGate from external source (exemple : GPS, weather station, external can bus...). The frequency sampling is up to 15 sample / seconds. Thanks to the python developer toolkit, a developer can easily develop an interface to inject the value inside NVGate. The GPS and weather station below have been develop using the DC simulated.
This option is include with the reference ORNV-VI-DC (wich also include the Virtual input).
How to use:
on acquisiton Tab, select connect input, select the DC inputs and select the DC simulated channels.
This channels can be activate and be put inside recorder and/or waterfall like any other DC channels.
The settings Value (wich can be controlled by an external software) will change the value of the inputs.
The others DC simulated settings details are explain on the front end settings page.
GPS
compatibility :
Android phone
Navilock NL-602U
Weather station
- manuel
- comaptibility davisinstruments weather station :
(need the 3 elements)
miscelisnious
Calibration
DC Dynamical sensor y = ax+b calibration
It is now possible to calibrate a dynamical sensor in "DC" or "DC floating" coupling using 2 values, then the software will automatically compute sensitivity and offset to obtaine the "y = ax + b" formula.
For using it, first create a DC sensor on the sensor database. Then apply this sensor to a channels.
Now on the calibration part, you can calibrate it using 2 values. Then the software will automatically and apply the sensitivity and offset.
Remove a sensor from history
If you have done a mistake during a sensor calibration, you can now delete a value from calbration sensor historic.
You need to ho on historic , select the sensor, select the value that you need to delete , then click on remove.
Displaying Time in Zoomed signal
Add on : Human body vibration
Add on : filter time signal with Wk, Wd, Wh ponderation https://wiki.oros.com/wiki/index.php/Human_Vibration
Orbit display include on FFT diag or ORD diag
For customer with option FFT-Diag or ORD-Diag , they will now have the Orbit display available in NVGate.
The orbit is available using the add/remove windows.
For details check the orbit dipslay page.