NVGo

From OROS Wiki
Revision as of 09:17, 27 April 2020 by Lmagimel (talk | contribs)
Jump to navigation Jump to search

NVGo

NVGo is the MODS monitoring software for android devices. This app is designed to:

  • Manage Templates for OR10 front-end and record setup,
  • Adjust the front-end and recorder settings
  • Continuously monitor the signals in different domains (level, time and spectral),
  • Start & stop recording,
  • Add properties and comments to records,
  • Manage records in OR10 memory.

Installation

1. Register on www.myOROS.com

2. From the Software section select NVGo -> Latest software

3. Download the latest NVGo Android Package Kit (.APK) on your Tablet or smartphone.

4. On your Android device open download section and select the NVGo .apk file, then choose install

5. Authorize the installation of unknown sources for once as OROS does not use Google play store for its software broadcasts.

Connection to OR10

1. Start NVGo from the Android device.

2. Power on the OR10 hardware

3. Wait for power-on until you get the main menu on the OR10 screen

4. Press "Wi-Fi" button on NVGo. The Android Wi-Fi menu is displayed

5. Connect to the OR10.

6. Press Android back () button to return in NVGo.


Refresh the instrument list. When your OR10 appears showing "Ready" Press on it to start NVGo with this instrument.


Main screen :



LiveView

LiveView screen shows the spectra and trigger blocks of the 2 highlighted inputs of the left column.

Displayed inputs are changed by swiping the graph up/down. It is also possible to select the displayed inputs by Pressping the selected input from the left column.

FFT settings allows adjusting averaging and resolution. Y scale may be set to linear or log. This preference is memorized in the Android device.


Signal

Signal shows the raw data envelope of the 2 highlighted inputs of the left column.

Displayed inputs are changed by swiping the graph up/down. It is also possible to select the displayed inputs by Pressping the selected input from the left column.

Y scale is continuously adjusted to input ranges. When the 2 active inputs show the same units, both Y scales are identical.

Levels

Levels shows the RMS and Peak levels of all dynamic inputs together.

Playback

Press the headphone icon on bottom right of the main screen to activate the playback. The 2 active inputs (blue background on the Signal and LiveView screens) are replayed on the OR10 headphone plug. The volume is automatically adjusted. Caution, the playback volume is dependent on the used headphone impedance. Signal amplitudes close to the range peak may generate high volume with low impedance headphone. Usage of very low impedance below 60 Ohms is not recommended. The stereo allocation of the played signals may be inverted by pressing the headphone button until the 2 background colors are inverted.

Setting up OR10

Load a Template

The Templates are generated and added to the OR10 memory with NVGate (see NVGate Template generation §). They are used in the same way as NVGate Models to setup the front-end with predefined settings. The Template properties and description will be saved in the Measurements made with it.

Press the central (Setup) field of the top ribbon to open the Template selection screen.

Adjust the Front-enD

Inputs settings may be adjusted manually. Press the left (Settings) BNC button of the top ribbon to open the Front-end settings screen.

Adjust the sampling frequency

The sampling frequency is always displayed in the main screen. Simply select the desired sampling rate from the Top ribbon drop down menu.

This menu is not available when the OR10 is recording.

Adjust the recorder

The recorder mode and duration may be adjusted. Press the left (Settings) Presse recorder button of the top ribbon to open the Recorder settings screen. This menu is not available when the OR10 is recording.

Select recorder mode between fixed duration Start to time and manually controlled Start to Stop.

For Start to time the duration should be updated by editing the field or using the +/- buttons.

Make a recording

Start recording

When the OR10 setup is done, the system is ready for start acquiring and saving the input data. To start the recording, Press on the bottom left Run button or press the REC button on OR10.

To stop the recording, Press on the bottom left Stop button or press the REC button on OR10. In Start to Time mode, the record will stop automatically, when duration time is reached.

Save & inform recorded data

When the record is finished, the save screen is shown.

Recordings are saved with the predefined base name of the used Template. A combination of a 3 digits number and a letter is added to manage the multi-acquisitions:

  • Letter is incremented while using the same Template for multiple acquisitions (called RUNs)
  • Number is incremented and letter reset when Template is changed.
  • Number and letter are automatically incremented to avoid overwriting existing files in the OR10 memory.

In that way, each RUN of a measurement type will be called: BaseName_102A, BaseName_102B, BaseName_102C, etc…

All the properties with contents are saved with the recorded data. Saved properties will be associated to the Measurement when records are imported in NVGate.

Check OR10 memory content

The OR10 recorded data may be browsed from NVGo. Press on the Capacity field (DAQ) from the Top ribbon right.

The Record list screen is displayed.