NVGate 2023: Release note

From OROS Wiki
Revision as of 15:59, 21 November 2023 by ChaoranDu (talk | contribs)
Jump to navigation Jump to search


OROS strives to be closer to its users, carefully listening to needs and requests. For that reason, OROS regularly releases new versions. Customers under contract automatically benefit from each release.


                                                     Splashscreen 2023 1.png



The NVGate® 2023 (V16), which is compatible with our latest hardware O4 and new solution Monitoring, became available in February 2023.

The NVGate® 2023.1 major version became available in November 2023. This release of the OROS 3-Series analyzer’s software platform brings additional functionalities and significant performance improvements. Below is a summary of the main enhancements of your NVGate experience:


>> 3 main features to avoid dramatic mistakes and bring efficiency to maximum

Advisor resize.png

Expert by your side all the time !

Modbus resize.png

Modbus TCP/IP client add-on compatibility

Tacho resize 1.png

Tachometer sensor setup can’t be simpler

As a newbie, have you ever wished to have an expert to check your settings, fix mistakes and explain why? As a pro, have you ever wished to be notified when you made the rookie mistake? With NVGate Advisor, your wish comes true!

Compatible with our new Modbus TCP/IP client add-on, which reads entries from Modbus server and injects the data to NVGate in real-time.

The most common rotating speed sensors are defined in the database, simply select yours from the list and the tacho setting is ready. Your sensor is not in the list? Easy, just add it to the database and setup becomes hassle-free.


This release note describes the content of the version, with operating details.
To download and install NVGate 2023.1, check this page.

Compatibility: NVGate 2023 is compatible with all OROS instruments (O4 - OR34 - OR10 - OR35 V1/TW - OR36 V2/TW - OR38 V2/TW) that have not been discontinued. Depending on the hardware options and version, some instrument features may or may not be available.


Advisor resize.png NVGate ADVISOR: Expert by your side all the time !

Have you ever hesitated in selecting analysis parameters ?

Have you ever spent hours trying to figure out why results are not as expected ?

Have you ever ended up with useless measurement data due to slight negligence in settings ?

As a beginner, have you ever wished to have an expert to check your settings, fix mistakes and explain why ?

As an expert, have you ever wished to be notified when you made the rookie mistake?

With NVGate ADVISOR, the metrology watchdog developed with OROS know-how accumulated over 40 years, you will always be accompanied by a noise and vibration expert.



NVGate ADVISOR brings to the user:

Notification

When one or more issues are detected, the user will be notified immediately by the “Advisor” icon in the “Home” tab and “Analysis” tab,

     

or by the icon at the lower right corner of NVGate.

     
     
  • - Display the data whatever the display type
  • - Use the display and analysis tools : zooming, scaling, cursor and markers reading results values
     
  • - Publish automated or manual reports

How to proceed?
Solely data created or shared from a NVGate 2022 version are compatible with the NVGate 2022 READER:
- For teams using a licensed version of NVGate, data generated with NVG2022 will be stored in the project manager and straightforward readable whenever starting in READER mode
- For READER users without any licensed version of NVGate, the data SHARED from your team member or partner can be imported using the "COLLATE" function.
- Embedded examples installed with the version are available for self training and can be displayed using the "EDIT MEASUREMENT" feature.

- For users who want to SHARE their data with READER users: they can do it using the "SHARE" function

- In all cases, shared DATA is initially created on a NVGate licensed version either in real time when connected to an OROS instrument or from a post-analysis based on a recorded signal

Ergonomics.png Enhanced ERGONOMICS : Save more clicks and push teams efficiency to the limits

Experience the enhanced field ergonomics and intuivity thanks to the optimized new Ribbon Tabs and application-oriented default settings. NVGate 2022 bring settings and displays at your fingertips in less clicks.

The interface gathers the analyzers functionalities in simple, clear and easy to identify tabs organized according to the main operations (Home, Acquisition, Analysis, Data, Display, Report, Automation, Preferences).









New default settings

The default settings in NVGate have been updated to the ones below. With these default settings, you can do rotating analysis measurement directly. Be aware that if you load an exiting project, the settings will not be affected. You can also easily change these settings.

FFT Overlap: 66%

FFT lines: 3200

FFT Overall low freq : 2 Hz


SOA resolution: 1/8

SOA overlap: 5

SOA OVL lower order: 0.2


Event Delta RPM: Delta velocity 10 rpm

Waterfall Depth: 1000

Tachometer/RPM Profiles/Duration: 120 sec






New Sound Power V3.20

OROS SOUND POWER Solution has been designed to let you achieve that type of test in the most efficient and accurate way.

This new version includes the following improvements:

  • New command to start directly the software on your pre-configured setup
  • Option to modify the limit of overall octave filter
  • Excel templates fully updated to the last standard
  • Full compatibility with NVGate 2022.

Read the dedicated Sound Power 3.20 release note for more info.

Bug fixing

  • 14729: CANBus J1939 compatibility
  • 15258: CANBus: Add CAN 2.0B
  • 15376: Tortional velocity measured from tacho at slow speed becomes 0
  • 15372: Phase difference between online results and post-analysis results
  • 15329: Integrator filter on accelerometer in teamwork mode, value in post-analysis is not velocity
  • 15314: In Japanese OS, “Next” button is not correctly loaded in display window
  • 15301: In cascade mode, the calibration process takes too long
  • 15299: No explicit error message when trying to load a post-analysis workbook in cascade mode
  • 15297: Rename measurement in teamwork mode, need to press refresh to see the change
  • 15293: Display reference profile waterfall is limited to 20 channels
  • 15220: The orbits (lissajou) in post-analysis are (sometimes) different from Online measurements
  • 15167: Signal corrupts with double sampling frequency in V16
  • 15147: Time marker mix-ups with several signals in the same project
  • 15124: Increase the number of spare units
  • 15047: Converting OR10 signal to ORXF format doesn’t work with CAN channels
  • 14913: 2 "Channel connection properties" windows at once
  • 14025: Press cancel when asked to save the measurement, the sequence jumps ahead