MultiPlane export 1X NVGate

From OROS Wiki
Revision as of 10:55, 23 June 2020 by Lmagimel (talk | contribs) (Created page with "===How to set up NVGate for Multi-Plane Balancing=== * SOA settings: Select '''Average = Time''', better for rotor balancing: Image:Collecting_data_with_NVGate_for_MP_Bala...")
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search

How to set up NVGate for Multi-Plane Balancing

  • SOA settings: Select Average = Time, better for rotor balancing:
Collecting data with NVGate for MP Balancing 01.png
  • SOA settings : PhaseRef=Cosine,
Collecting data with NVGate for MP Balancing 02.png
  • Set the Ext Synch inputs Rotation as ClockWise
Collecting data with NVGate for MP Balancing 03.png

  • Bode Plot 1X : Magnitude vs Speed :

Select the "Ord1 Tach" for the bode plot. This speed is evaluated at the middle of the trigger block whereas the "Tach Ext Ang speed" is the speed at the beginning of the trigger block.

Collecting data with NVGate for MP Balancing 04.png
  • Interpolation : prefer to use interpolated delta RPM event for Waterfall trigger. Indeed, the MP balancing process needs several transient speed runs. In order to get synchronized runs, we advise to use the interpolated delta RPM for the Waterfall trigger.
Collecting data with NVGate for MP Balancing 05.png
  • Export toward TXT files:

Export results through File Tab => Results Files (check the format export in the picture on the right)

Collecting data with NVGate for MP Balancing 06.png

It is also possible to trigger exporting after each measurement (through Save setup):

Collecting data with NVGate for MP Balancing 07.gif