NVGate V17: Release note

From OROS Wiki
Jump to navigation Jump to search


OROS strives to be closer to its users, carefully listening to needs and requests. For that reason, OROS regularly releases new versions. Customers under contract automatically benefit from each release.

                                                     Splashscreen V17.png


This new major version of NVGate unlocks the full potential of OROS Framework, empowering you with advanced customization options and complete control over your data – keeping you ahead with cutting-edge tools for efficient and tailored signal management at no additional cost.


This release note describes the content of the version, with operating details.
To download and install NVGate V17, check this page.
Compatibility: NVGate V17 is compatible with the following OROS instruments: O4 - OR10 - OR35 TW - OR36 TW - OR38 TW.


New Data Structure: Redefining Flexibility for Modern Signal Management

Time signals are now stored using a brand-new structure that optimizes both signal processing and data management.

Multiple Parts and Recorder Configuration

Users have the flexibility to configure each time signal to include multiple records, with each record further divided into parts of customizable lengths.


Multirecord multipart.png


By default, the recorder is configured with a single record and the part length set to 'Auto' as below:


Recorder conf 1.png


The duration of a part can be configured in the advanced settings as below:


Recorder conf 2.png


  • Single file: Only 1 part per signal.
  • Short: Part length is set to 64 seconds.
  • Medium: Part length is set to 640 seconds.
  • Long: Part length is set to 1920 seconds.
  • Auto: The part length depends on the recording mode:
    • "Start to stop" mode: Part length is set to 640 seconds.
    • "Start to time" mode:
      • If duration is longer than 100 hours, then part length is set to 1920 seconds;
      • If duration is between 10 and 100 hours, then part length is set to 640 seconds;
      • If duration is between 5 and 10 hours, then part length is set to 128 seconds;
      • If duration is less than 5 hours, then part length is set to 64 seconds.
    • "Time to stop" mode: For duration of 1024 seconds or longer, the part length is set to 64 seconds. For shorter duration, the first power of 2 greater than duration/16 is selected. A minimum part length is enforced when the total record bandwidth is high. When the combined bandwidth of all recorded inputs exceeds 256 kHz, 512 kHz, or 1024 kHz, the minimum part length is set to 8, 16, or 32 seconds, respectively.

Key New Features introduced by the New Data Structure

Real-Time Zoom

Drag and drop the section of the signal you're interested in while recording, and the selected part will be instantly zoomed in. You can zoom in on multiple sections simultaneously in different windows, enhancing your real-time analysis and visualization capabilities.


Recording zoom.png



Concurrent Analysis

Selective Sharing

Large Signal Handling

Segment & Edit

OROS Framework: Free of Charge, Unleash Customization, Unlock Limitless Potential

Bug fixing