Notices and General safety instructions

From OROS Wiki
Jump to navigation Jump to search

This is the notice and general safety instruction for using OROS OR3X analyzer

Notices

The information contained in this document is subject to change without notice.

Responsibilities

OROS is not liable for any errors contained in this document.

OROS makes no warranties of any kind with regards to this document, whether express or implied. OROS disclaims the implied warranties of merchantability and fitness for a particular purpose.

OROS shall not be liable for any direct, indirect, special, incidental, or consequential damages, whether based on contract, tort, or any other legal theory, in connection with the furnishing of this document or the use of the information in this document.

Warranty Information

A copy of the warranty terms applicable to your OROS product and replacement parts can be obtained from your local distributor. A copy of the extended warranty (service contracts) terms applicable to your OROS product can be obtained from your local distributor.

Please visit https://www.oros.com/find-us/ to find your local distributor details.

Calibration/Verification

OROS instruments needs to be calibrated regularly. OROS recommend to verify and calibrate your instrument yearly.

Note: The calibration does not guarantee the measurements accuracy for the coming year. It guarantees that your previous measurements do not show erroneous results.

Support

Support (hotline, trainings, coaching, renting, customization, update) are managed locally by country with the support of OROS customer care team. For any support please contact your local distributor first.

Please visit https://www.oros.com/find-us/ to find your local distributor details.

Service/repairs

OROS offers local service and repairs through its maintenance centers available within a worldwide coverage (China, Europe, India, Japan, South Korea, USA). Local technicians are certified on a regular basis by OROS specialists, enabling them to repair, calibrate and upgrade all OROS systems reducing the maintenance downtime.

Please visit https://www.oros.com/find-us/ to find your local distributor details.

General Safety Instructions

Usersmanual 42.gif

Read the manual before use. It provides important safety information.

Your safety is our primary concern. Please carefully read the following information to be safe with your OROS instrument.

Safety symbols in the manual

Warning

Usersmanual 43.gif

Calls attention to a procedure, practice, or condition that could cause body injury or death.

Caution

Calls attention to a procedure, practice, or condition that could possibly cause damage to equipment or permanent loss of data.

Warnings

The following general safety precautions must be observed during all operations with OROS instruments.

Failure to comply with these precautions or with specific warnings elsewhere in this manual violates safety standards of design, manufacture, and intended use of the product. OROS assumes no liability for the customer’s failure to comply with these requirements.

Notice

Some accessories shown in this document are available as option and will not be shipped as standard parts.

Environmental Considerations

The following guidelines must be observed to avoid environmental pollution while using and recycling the OROS products.

Product End-of-Life Handling

Observe the following guidelines when recycling an OROS instrument:

System and Components Recycling: Production of these components required the extraction and use of natural resources. The substances contained in the system could be harmful to your health and to the environment if the system is improperly handled at its end of life.

Please recycle this product in an appropriate way to avoid unnecessary pollution of the environment and to keep natural resources.

This symbol indicates that this system complies with the European Union’s requirements according to Directive 2002/96/EC on waste electrical and electronic equipment (WEEE) According to article 9 of directive 2002/96/EC, costs for collection, treatment, recovery and environmentally sound disposal of waste electrical and electronic equipment (WEEE) shall be provided by the users. French users, please consult our local policy @ www.oros.fr.

Restriction of Hazardous Substances

This product has been classified as Monitoring and Control equipment, and is outside the scope of the 2002/95/EC RoHS Directive. OROS products complies Directive with RoHs. Our products are lead free. Pollution degree 2.

General safety and hazard warnings for OROS Instruments

Review the following safety precautions to avoid injury and prevent damage to this product or any products connected to it. To avoid potential hazards, use this product only as specified. Only qualified personnel should perform service procedures. Usersmanual_45.gif To avoid fire and personal injury: Use proper power cord. Use only the power cord specified in this product and certified for the country of use.

Connect OROS Teamwork instruments to the ground. This product is grounded through the grounding conductor of the power cord. To avoid electric shock, the grounding connector Usersmanual 46.pngmust be connected to earth ground.

To avoid electric hazards during battery operation, connect OROS Teamwork instrument to the ground Usersmanual_47.png.

Respect all terminal ratings. To avoid fire or shock hazard, observe all ratings and marking on the product. Do not apply voltages over +/-60 V to any terminals and covers of the instruments.

Do not operate without covers. Do not operate this product with covers or panels removed.

Avoid exposed circuitry. Do not touch exposed connections and components when AC outlet is connected.

Do not operate with suspected failures. If you suspect there is any damage to this product, get it inspected by qualified service personnel.

Only use original and approved devices, components and accessories. Apply them in accordance with their intended use.

Maintenance of the instruments and accessories is operated in OROS certified maintenance center only.

Adverse environmental conditions : Take specific protections when operating the instrument exposed to the following conditions

  • Do not operate in wet/damp conditions for outdoor operations.

Usersmanual 49.jpg indoor, dry location use only.

  • Do not operate in explosive atmosphere (Dust, flammable gases/vapors, fumes or dissolver).
  • Keep product surfaces clean and dry.
  • Provide proper ventilation. See the "Fan" chapter.
  • Do not operate the instrument out of the temperature, shock and vibration absolute maximum ratings (see compliance with standards).
  • Do not operate in environments where pollutants may be present.

Electrical and radio frequencies

Electrical and radio environments

OROS instruments are designed to operate in office, laboratory, on-board and industrial environments regarding electrical and radio disturbances.

Radio frequencies sensibility
  Input measured with 50 Ω terminator
Radiated RF: 80-1000 MHz, 80% AM 1 kHz, 10 V/m < 20 µV
Conducted RF: 0.15-80 MHz, 80% AM 1 kHz, 10 V < 100 µV
Magnetic field: 30 A/m, 50 Hz < 2 µV

Compliance with standards

CE\CB\FCC Indicates compliance with EMC Directive 89/336/EEC, 2014/30/EEC and Low Voltage Directive 73/23/EEC
Safety EN 61010-1 Safety requirements for electrical equipment for measurement, control and laboratory use.
Over-voltage Cat. II (Local level mains, appliance, and portable equipment)
EMC Emission EN 50081-1 Generic emission standard: Residential, commercial and light industry.
EN 50081-2 Generic emission standard: Industrial environment.
IEC 61326-1 Electrical equipment for measurement control and laboratory use EMC requirements.
CISPR 22/32 Radio disturbance characteristics of information technology equipment.: 22 Class B limits.
FCC Rules Complies with the limits for a Class B digital device.
EMC Immunity EN 50082-1 Generic immunity standard: Residential, commercial and light industry.
IEC 61326-1 Electrical equipment for measurement control and laboratory use EMC requirements.
EN 50082-2 Generic immunity standard: Industrial environment.
Linear input response range on interference max slew rate on input: 5 V/ µs
EMF Recommendations 199/519/CE EN 62311 Evaluation of person exposure to electromagnetic fields
Materials ROHS 2011/65/EU
WEEE 2002/96/CE - 2003/108/CE - 2012/19/EU
Humidity Max 80 % RH at 40°C non-condensing
Temperature OR34, OR35, OR36 Operating -20°C to 50°C (32°F to 122°F)
OR38 Operating -20°C4 to 45°C (32°F to 113°F)
Storage -20°C to 65°C (-4°F to 149°F)
Absolute maximum ratingii -35°C to 70°C (-31°F to 158°F)
Shocks Complies with IEC 68-2-27
Operating 100 m/s² (11 ms, ½ sine) and 700 m/s² (3 ms, ½ sine)
Storage 200 m/s² (11 ms, ½ sine) and 1 000 m/s² (3 ms, ½ sine)
Absolute maximum ratingii 1 000 m/s² (3 ms, ½ sine)
Vibrations Complies with IEC 68-2-6
Operating 10 m/s², 5-500 Hz, 5mm
Storage 25 m/s², 5-500 Hz, 5mm
Absolute maximum ratingii 30 m/s², 5-500 Hz, 5mm
Enclosure OR35 IP 40
OR34, OR36, OR38 IP 42