NVGate Post Analysis

From OROS Wiki
Jump to navigation Jump to search

The Post Analysis of a signal is a mode of NVGate where the physical input of the frontend are replaced by the tracks of the signal load in the player. This will allow you to re-analyse a signal previously recorded. Therefore, this mode can be used to calculate new result from a previous measurement, or re-calculate results with different setups.

The post analysis mode can be made in connected (starting NVGate with the analyser) or office mode (starting NVGate with the dongle). However, we strongly advise to perform post analysis in Office mode, as the communication between the PC and the analyser will limit the performances. To do so, the signal must have been downloaded from the analyser to the computer.

Tutorial

In this tutorial, we will perform the post analysis of a signal recorded during a previous measurement with an OR36TW.

Parameters

Loading a signal

In this section, we detail the two different method to load a signal in post analysis mode.

New setup option

This first option allow you to post analyse the signal with a brand new setup. It will load a signal in the player, display the preview of the signal envelope, and switch to post-analysis mode.

  • From the Home tab / Start group, press the Post-Analyze button. This will display a selection of signal files available for post-analysis:
Player pa.png


Click on the descending arrow to select New:

MenuNewSetup.png


This will open the connection properties widow, and you can connect your tracks in the different module to perform your post analysis.

NewConnecTracks.png


  • From the project manager, by right clicking on the signal you want to analyze. Choose Post-Analyze , and click on New:
ProjManagerNewSetup.png


As previously, this will open the connection properties widow, and you can connect your tracks in the different module to perform your post analysis.

NewConnecTracks.png



if you are already in post analyse mode, the current setup will not be deleted if you load a new record with this method. Therefore, you can use this method to post Analyse two record witht the same analysis setup. However, the records must have the same track number and type.

Keep recording setup option

This second method will allow you to post analyse the signal with the same setup used for the recording. As previously, this will load signal in the player and display the envelope of the recorded signal, switch to post-analysis mode, and keep the setup used during the record signal by replacing dynamical input of the frontend by the player tracks. Note: 'if the record setup contains virtual inputs, torsional channels, CAN or DC channels, the connection of these channels to the plug-ins will be reset.

Connecting the tracks in NVGate

Connect tracks to the differents modules

A faire : Connecter les voies en PA, GoToResult vs TDA

Connect a tachometers and torsional channels

connecter les PA

A préciser : une fois qu'on est en PA, on peut post analyser un autre signal juste en le loadant dans le player.

Batch Post Process