NVGate Diesel Engine Vibration Solution: EngineDiag

From OROS Wiki
Jump to navigation Jump to search


Installation

EngineDiag is a module integrated in NVGate.

Follow the steps described in the NVGate User's manual to install it correctly.

For the Angle-Frequency option, it's necessary to install a complementary application: 'SetupAngleFrequency.exe'.

Double click on EngineDiag 06.png . The following window will appear.

EngineDiag 07.png

Click on Next, the following window will appear.

EngineDiag 08.png

Select the destination folder and click on Install.

Note: if you change the default destination folder, be careful to install the Angle-Frequency module in the same directory than NVGate as the example below:

EngineDiag 09.png

When the installation is completed, click on Close.

Environment configuration

With the EngineDiag module a new ribbon is available in NVGate. EngineDiag allows to access to NVGate through an interface dedicated to the engines and more generally to the reciprocating machines.

EngineDiag 10.png

Properties

To simplify the data saving, the history creation, the data search, it is possible and recommended to associate metadata to each measurement.

One can distinguish two types of metadata:

  • Properties related to a measurement campaign
  • Properties related to each measurement.

Properties are defined by default in NVGate but the list of properties can be modified according to the user need.

The list of properties is available in the Home ribbon by clicking on Measurement properties.

EngineDiag 11.gif
EngineDiag 12.png

This window shows all the properties used.

For each of them one defines two fields:

  • Apply to: indicate where the property will appear.
  • Apply to measurement: the property will appear in the save measurement only
EngineDiag 13.png
  • Apply to Operation: the property will appear in the operation window and in the save measurement window. The user can pre fill in some of values in the window Operation available in the Engine ribbon.
EngineDiag 14.png
  • Apply to nothing: the property will not appear.
  • Suggest
  • Empty : the property is empty by default
  • Same as previous: by default the property keep the last value entered by the user.
  • Same as today: the property keeps the same value during one day. The day after the value is reset to empty.

By selecting show all in this window, all the properties, even those that are not used anymore, are displayed.

EngineDiag 15.png

Operation

These properties related to a measurement campaign are generally common to several measurements done the same day on the same installation. Instead of writing this information for each measurement, it's possible to define the environment once before stating the measurement.

This information can be defined in the operation window available by clicking on the button EngineDiag 16.png .

Below, the properties by default:

EngineDiag 17.png

The properties can be defined directly in this window as the following example

EngineDiag 18.png

At this stage, new properties can be added if needed by clicking on Add new in this window

EngineDiag 19.png

Select OK.

All these properties will be added to each measurement done this day.

MeAsurement

In the save measurement window, all the activated properties are displayed.

The properties pre-filled in the operation window appear with the value defined by the user in the operation window.

EngineDiag 20.png

Engine Configuration

One of the objectives of the EngineDiag module is to integrate in NVGate the physical data related to the engine under test in order to have all this information during the analysis.

The design and the kinematic information can be described by clicking on the button Engine.

EngineDiag 21.gif

The following window is displayed.

EngineDiag 22.png

From this window a complete Engine model can be described.

An Engine model contains the:

  • Engine designation
  • Engine settings
  • Timing information
  • Instrumentation
  • Type of analysis applied to this engine

This information can be saved in an independent file .engine, in the NVGate projects and in the measurements.

Engine

From this first panel, several actions are available:

  • New: create a new Engine model

By clicking on "new", a default engine model is loaded and the "settings" panel is automatically displayed.

From here some modifications can be done.

  • Load: Load an existing engine model

By clicking on "Load", an existing engine model can be loaded by selecting a file .engine.

  • Remove: Remove the current engine model
  • Save as: Save the current engine model to a file

This panel gives also the model name defined in the settings panel and all the comments written by the user. The field "comments" is saved in the engine model.

Settings

The settings panel allows to describe the engine characteristics.

EngineDiag 23.png

The 3 fields: Nominal power, rated speed and cylinder bank angle are here for information. The results are not influenced by these values.

The others settings will influence the results.

  • Cylinder configuration: Vee or In Line
  • Engine cycle: 2 strokes or 4 strokes
  • Cylinders number: indicate the cylinders number
  • Rotating Direction: Clockwise or counterclockwise

With this information, a schematic picture is automatically drawn. The cylinders names can be modified by clicking directly on them.

On this picture, the small numbers in red represent the firing order. This order can be modified panel below the picture.

Timing

The timing panel allows to describe the timing information generally provided by the engine manufacturer.

EngineDiag 24.png
  • The events table

The events table allows define the kinematic events (Intake opening, exhaust opening,…) and position them in relation to the events Top Dead Center (TDC) and Bottom Dead Center (BDC).

An event is defined by:

  • an angle from the TDC or BDC,
  • its position in the engine cycle. This information is important for four-stroke engines. It's necessary to know if the event appears in the first or in the second crankshaft revolution.

Every modifications done in the events table is automatically reported on the two graphs displayed here. At the top, a typical timing diagram and at the bottom the linear engine cycle representation.

A new event can be added by clicking on EngineDiag 25.png below the events table.png]] .

  • The phases table

From the events described in the events table, the different phases of the engine cycle can be defined. Each phase is defined by its start and stop event as well as a color. The settings can be modified by double clicking on the concerned setting.

A new phase can be added by clicking on EngineDiag 27.png below the phases table. The selected phase can be removed by clicking on EngineDiag 28.png .

  • Tachometer reference

The tachometer reference is the event synchronized to the tachometer that will be used for the synchronous analysis.

In the example below, the tachometer reference is TDC A1 because the pulse is synchronized with this event.

EngineDiag 29.png

Instrumentation

The objective here is to describe the instrumentation installed on the engine under test to keep it in memory.

Cylinders instrumentation

This panel displays the instrumentation installed on the cylinders.

For each cylinder, one can define:

  • Analyzer input,
  • Label,
  • Type of transducer by using the transducer database. The sensitivity of the selected transducer is automatically displayed.
EngineDiag 30.png

Several transducers can be installed on the same cylinder. Define the maximum number of inputs per cylinder. See the example below with 3 inputs.

EngineDiag 31.png

Other instrumentation

In addition to the cylinder instrumentation, others transducers can be installed on the machine.

EngineDiag 32.png

Several groups of transducers can be defined often associated to a machine part: bearing, absorber...

Double click on "New part" to define the part name and click on EngineDiag 33.png to add a new part.

Several transducers can be associated to each part. By selecting a part, the associated transducers are automatically displayed.

EngineDiag 34.png

By selecting all the parts simultaneously, all the transducers installed on the engine are displayed.

EngineDiag 35.png

Analysis

The Analysis panel allows to select the type of analysis that will be done. This information will be used to help the user to configure NVGate.

EngineDiag 36.png
  • The recorder use the NVGate recorder
  • The synchronous analysis uses the Synchronous order plug-in
  • The asynchronous analysis uses the FFT plug-in

When the engine model is defined do not forget to save it in the Engine panel with the Save as button.

NVGate configuration

The Advisor

From the parameters defined in the engine model, the Advisor will help the user to configure NVGate correctly.

The advisor is a help, it's not compulsory to use it for the configuration.

EngineDiag 37.png

The advisor gives a status about the software configuration depending on the Engine model.

Using different colors, the advisor indicates the current status of the NVGate configuration

EngineDiag 38.png
The measurement will not be done correctly. The configuration should be adjusted.
EngineDiag 39.png
Regarding the type of analysis selected, some settings are missing to obtain all the results.
EngineDiag 40.png
Regarding the type of analysis selected, the NVGate configuration is correct. The user can choose which results he wants to display and start the acquisition

By clicking on the Advisor button, all the errors will be displayed with title, explanation and criticality as below.

EngineDiag 41.png

For each error, the advisor indicates if it can be solved automatically EngineDiag 42.png or manually EngineDiag 43.png .

  • Click on EngineDiag 44.pngwill automatically set up NVGate to solve the error.
  • Click on EngineDiag 45.png will open the window where the user has to do an action to solve the error.

To gain time, the function "Fix All" available by the button EngineDiag 46.png allows to fix all the displayed errors that can be solved automatically.

EngineDiag 47.png

The" Fix Selected" function, available by the button EngineDiag 48.png , solves the selected errors in the list.

The advisor gives only advices. The user can read the information and decide to ignore some of the errors. Each error can be hidden by clicking on the button hide showed below

EngineDiag 49.png

The "Hide Selected" function, available by the button EngineDiag 50.png , allows to hide several errors at the same time by selecting them.

All the hidden functions are not deleted. At every time the user can display all of them by clicking on the button EngineDiag 51.png .

The advisor displays the important rules to make a correct measurement but the NVGate configuration is not restricted to the advices showed here.

All the capabilities of NVGate are available. The user can complete this first configuration to adapt perfectly the configuration to its application.

The dedicated results

With the Engine Module, several dedicated results are available.

These results can be displayed through the window "Add/Remove window" available in the ribbon "Display/Graphs".

EngineDiag 52.png

And also in the ribbon "Engine".

EngineDiag 53.png

Time signal - The Triggered block Engine

The triggered block engine is a new result of the Synch order plug-in associating the engine information to the standard synchronous triggered blocks.

Select the results as below:

EngineDiag 54.png

The following window will be displayed

EngineDiag 55.png

Specific features:

  • The results are displayed automatically in the firing order defined in the window Engine/Settings


EngineDiag 56.png
  • The cycle overview (defined in Engine/Timing) of each displayed cylinders is shown at the bottom of the window. The cycle overview of each cylinders is determined thanks to:
  • The tachometer reference
  • The firing order
  • The timing diagram
  • 2 cursors displayed on the signals and the cycle overview allow to identify the kinematic events on the signals.
EngineDiag 57.png

On the example above the cursors are positioned at the beginning of the 2 main events of the signal. Looking at the cycle overview, one can notify that:

  • the first cursor corresponds to the end of the exhaust phase, ie the exhaust valve closing
  • The second cursor corresponds to the end of the intake phase, ie the intake valve closing.
  • By default, only one cycle is displayed in this window, 360° (crankshaft angle) for a 2-strokes engine or 720 ° (crankshaft angle) for a 4-strokes engine. More cycles can be displays. The number can be defined in the Engine Ribbon.
EngineDiag 58.png

The max number of cycles that can be displayed depends on the order resolution defined in the Synch order plug-in.

Order resolution Max number of cycles
for 2-strokes engine
Max number of cycles
for 4-strokes engine
1 1 0
½ 2 1
¼ 4 2
1/8 8 4
1/16 16 8
1/32 32 16
  • The signals can be aligned on a same event by selecting the 'align' function in the Engine Ribbon.
EngineDiag 59.png

Comparison

This Trigger Block Engine result can be saved as any NVGate results. Add the results in the Save selection Tab available in the Save setup window accessible in the Measurement Ribbon.

EngineDiag 60.png

Otherwise right click in the window and click on 'Add to result selection like below.

EngineDiag 61.gif

The new saved results will appear in the Project Manager.

EngineDiag 62.png

The save results can be compared between them or with current result in the same window.

To add result in a window, drag&drop the result from the project manager to the window.

EngineDiag 63.png

The cycle overview of each of the measurements is also displayed.

The averaged RMS Engine

The Averaged RMS Engine is a result available in the Waterfall allowing to display the RMS level of the cylinders calculated on the engine cycle and averaged on the measurement.

This new result is based on the RMS level calculated in the Synch. Order plug-in.

Select the results as below:

EngineDiag 64.png

The following window will be displayed.

EngineDiag 65.png

This window shows the averaged RMS value on the engine cycle for each cylinder. The viewmeter indicates the value and the symbol EngineDiag 66.pngrepresents the standard deviation.

These values are all displayed in a summary table in the infotrace.

After a first visualization of the global RMS level calculated on the complete cycle, it's possible to display the RMS level of each phase of the cycle, typically the combustion, the exhaust, the intake and the compression.

To display these results, click on one phase of the cycle overview displayed at the bottom of the window.

Below the RMS level calculated during the combustion.

EngineDiag 67.png

To come back to the global RMS level calculated on the cycle, double click on the cycle overview.

Comparison

This Avg. RMS Engine result can be saved like the others NVGate result. Add the results in the Save selection Tab available in the Save setup window accessible in the Measurement Rubon.

EngineDiag 68.png

The new saved result will appear in the Project Manager.

EngineDiag 69.png

To compare results, drag&drop the results from the Project Manager to the window.

The software will automatically arrange the results by cylinder and date. The results are grouped by cylinders and the first result displayed is the older one.

EngineDiag 70.png
EngineDiag 71.png

There is no limitation regarding the number of results that can be displayed at the same time.

To remove results, right click on the window, select 'Remove results' and the results one wants to remove.

EngineDiag 72.gif

This display allows to compare few measurements. To make trend analysis on several measurements, it's possible to change the display mode.

The 2 modes are available by right clicking on the window and select display mode.

EngineDiag 73.gif
EngineDiag 74.png
EngineDiag 75.gif
EngineDiag 76.png

The History mode shows the values with the standard deviation in absolute time. It allows to follow the parameters during a long period.

In this representation, a color is associated to each cylinder. The same color is used on the graph and in the results table in the infotrace.

Angle-Frequency analysis and display

Angle-Frequency analysis is interesting when working on reciprocating machine. It allows to identify specific events.

The method implemented in the software is based on the Wigner-Ville algorithm.

This method is particularly adapted for short transient signal where the STFT is not sufficient. Another advantage is the good resolution both in angle and frequency one can obtain.

The principle is to represent the energy density on a colorspectrogram using the Wigner-Ville distribution (W (θ, f)). The relevance of the results of such analysis depends on settings including angle and frequency resolution.

From this representation, additional results are extracted to make the analysis easier. They correspond to the integration of the energy densities on the engine cycle and on a selected frequency range. They are defined as follows:

- Energy spectrum S (f ) = òS (q,f )dq

- Instantaneous power P (q) = òS (q,f )df

This analysis is available in post-analyze only.

A dedicated window

Before starting, note that this analysis is available in post-analyze only.

If a signal is loaded in the player, click on the button angle-frequency in the Engine Ribbon to open the following dedicated window.

EngineDiag 77.png

It's also possible to use the angle-frequency analysis on another signal not loaded in the player.

In this case, right click on the concerned signal in the project manager and select Angle-Frequency Analysis.

EngineDiag 78.gif

Result manager

The Result manager shows the signal(s) and the tracks that will be analyzed in angle-frequency.

Click on the button EngineDiag 79.png. The following part of the window will appear.

EngineDiag 80.png
  • Signal

One can see the selected signal name and the corresponding project.

It's possible to open several different signals in a same window by clicking on "open signal".

  • Tachometers

The second step is to define the tachometers that will be used for the analysis:

  • Assoc. Tach: define here the tachometer that will be used for the synchronous analysis.
  • Samp. Pulse: indicate here the tachometer that will be used for the angular sampling. This signal must contain several pulses per revolution and will lead to a better accuracy in angle. Nevertheless, it's not necessary to define a sampling pulse. The angular sampling can be done with the Assoc. Tach. In this case, set this parameter to none.
  • Tracks

Select the tracks that will be analyzed and displayed and click on 'Add track'. If several signals are loaded in the window, the displayed tracks list will depend on the selected signal. Select each signal one by one and choose the tracks for each of them.

EngineDiag 81.png

After this first step, it's possible to click again on EngineDiag 82.pngto reduce this window part.

Settings

Three parameters have to be set up, the angular resolution, the frequential resolution and the average size. They can be modified in the window bar:

EngineDiag 83.png
  • Angular resolution: this parameter determines the angle that separates two values in the angle axis. The maximum resolution can be determined in function of the machine.

For example, working on a 4-strokes 12 cylinders diesel engine, the angular resolution must be lower than 720/12= 60° to be able to differentiate all the events on the different cylinders.

  • Frequential resolution: This parameter determines the frequency that separates two values in the frequency axis.
  • Average size: This parameter is the average number used to calculate the Wigner-Ville spectrum. For this result, the average is made on the engine cycle (720° for a 4-strokes engine and 360° for a 2-strokes engine). In most cases, set the average number to 100 lead to good results.

When these parameters are set up, click on EngineDiag 84.pngto launch the computation and display the result.

Engine diag2.png

Results

The window is shared in several parts to present all the useful information.

EngineDiag 85.png

display tools

Each graph can be maximized by clicking on the following button in the top right corner of each graph. Move the mouse over this area to let the button appear.

EngineDiag 86.gif

In the same way, click on the following button to come back to the default view.

EngineDiag 87.gif
  • Cursors

By default the energy spectrum and the instantaneous power are calculated from the complete colorspectrogram.

With the mouse, it's possible to select a part of the colorspectrogram and calculate the energy spectrum and instantaneous power from this selection.

The previous selection can be moved and modified. The results are automatically adjusted depending on the selection.

Double click on the colorspectrogram to come back to the selection by default (the complete colorspectrogram).


2 vertical and 2 horizontal cursors are available on the colorspectrogram. The horizontal cursors are linked to the 2 cursors on the energy spectrum. The vertical cursors are linked to the 2 cursors on the instantaneous power and to the 2 cursors on the cycle overview.

All the cursors values are noted in the infotrace.

Engine diag.png

Comparison

Tracks from the same signal

Open the result manager part

EngineDiag 88.png
EngineDiag 89.png

All the tracks available in the opened signal are showed. Select the tracks, click on add track and click on the button Compute to add these results in the window

EngineDiag 90.png

Here, one colorspectrogram is displayed.

EngineDiag 91.png

indicates the displayed tracks.

The buttons

EngineDiag 92.png

at the left top corner allow to navigate among the results and visualize the various calculated colorspectrograms.

Report

To add the angle-frequency results in a report, go to the report ribbon, select the active Word file and drag&drop the Angle frequency icon to the document.


EngineDiag 93.png