Difference between revisions of "NVGate Player"

From OROS Wiki
Jump to navigation Jump to search
Line 31: Line 31:
NVGate® proposes 2 different types of windows for displaying the signal.
NVGate® proposes 2 different types of windows for displaying the signal.
[[Image:Player windows.png|framed|none]]<br>
[[Image:Player windows.png|framed|none]]<br>
* One for the file overview providing a compressed view of each record.
* The signal File is for the file overview providing a compressed view of each record.


[[Image:Player_connection_wizard_07.png|framed|none]]<br>
[[Image:Player_connection_wizard_07.png|framed|none]]<br>
Line 39: Line 39:
[[Image:Zoomed.png|framed|none]]<br>
[[Image:Zoomed.png|framed|none]]<br>


You can zoom a specific part of the signal selected with the mouse. This operating mode allows an easier navigation inside the recorded domain file to locate the part of interest. If you are in post-analysis mode, only the selected part of the signal will be analyzed.
You can zoom on a specific part of the signal selected with the mouse. This operating mode allows an easier navigation inside the recorded domain file to locate the part of interest. If you are in post-analysis mode, only the selected part of the signal will be analyzed.


* The filter signal is only available in on_line connected mode if a filter is applied. It allow you to see the filtered signal.
* The filter signal is only available in on_line connected mode if a filter is applied. It allow you to see the filtered signal.

Revision as of 17:52, 21 May 2020

The Player module is used to playback temporal signals in NVGate. The signal can be a previously recorded signal or an imported signal. Once loaded in the player, the signal can be displayed, listen trough the computer audio port and post-analysed. In this way, you can re-inject the recorded signals into any NVGate plug-in (Monitor, FFT, 1/n Octave...). It is also possible to play back a recorded signal through the Output during On-line analysis.

This page will present you the different usages of the player.

Load a signal for post analysis

  • From the Home tab / Start group, press the Post-Analyze button. This will display a selection of signal files available for post-analysis:
Player pa.png
  • From the project manager, by right clicking on the signal you want to analyze. You can choose to preview, load, load & preview or Post-Analyze it.
Player connection wizard 02.png


1. Preview let you visualize the recorded signal envelope. Contents of signal files can be visualized in a high-speed preview even if you are manipulating huge file. This new technology allows multiple files preview at the same time. Very large domain record (several Gigabytes) can be previewed in a click, even if the hardware is not connected. Means that the files can be located on the hardware OR3x disk and visualized (not post-analyzed) on the PC without request of downloading, or Hardware connection.

2. Load in player makes your signal available in the player without viewing it.

3. Load & Preview is a combination that let you see the envelope of the recorded signal you loaded.

4. Post analyze/new is a combination that let you see the envelope of the recorded signal you are loading, switch to post-analysis and start a new setup menu for post-analysis. (if you are already in post analyse, the current setup will not be delete)

5. Post analyze/Keep record setup is a combination that let you see the envelope of the recorded signal you are loading, switch to post-analysis, and keep the setup used during the record signal by replacing dynamical input of the frontend by the player tracks. Note: 'if the record setup contains virtual inputs, torsional channels, CAN or DC channels, the connection of these channels to the plug-ins will be reset.
The video below explain the post analyse "Keep record setup"

Display the signal

NVGate® proposes 2 different types of windows for displaying the signal.

Player windows.png


  • The signal File is for the file overview providing a compressed view of each record.
Player connection wizard 07.png


  • The second type is the zoom on the analyzed part (between the start and stop offset cursors).
Zoomed.png


You can zoom on a specific part of the signal selected with the mouse. This operating mode allows an easier navigation inside the recorded domain file to locate the part of interest. If you are in post-analysis mode, only the selected part of the signal will be analyzed.

  • The filter signal is only available in on_line connected mode if a filter is applied. It allow you to see the filtered signal.

Available results

Type Size Dimension Domain Save
Signal File 2048 compressed pt max 2D Compressed time Display only

There are 2 modes for the player:

  • Post-analysis, the player takes place of the front end; the signal can be analyzed by any plug-ins.
  • Play-back on output In connected mode on-line, signals are played on the output (load files in the player and connect tracks to outputs). Note that the Input sampling must be the same as player max bandwidth x 2.56.

Play-Back on PC speaker

From any of the previous configurations, the recorded signal could be listened on the PC loud speakers.

Player playback.png

Click on Player connection wizard 06.png in the active window. The button stops the play back at any time. A mobile cursor (blue) localizes the played back signal part in the signal window.

Connect the player tracks on the output

Once the signal is load, you can play the tracks on the output of the frontend :

ConnectToOutput.png

Player option

The option of the player are accessible and can be modified from the ASB:

PlayerInASB.png


  • Signal file: the name of the measure containing the signal file.
  • Record number: defines the record to be processed (if the signal file contains more than 1 record).
  • Start offset: the beginning position of the part of signal to analyze or play (0 <= Start Offset < Stop Offset).
  • Stop offset: the end position of the part of signal to analyze or play (Start Offset < Stop Offset <= selected record duration).
  • Duration: the duration of the selected part of signal between the Start offset and the Stop offset.

Hidden/fixed: Fixed

  • Repeat 'mode': On/Off: used to repeat playback of the selected part of the signal indefinitely. The repeat mode is not enabled in post-analysis mode.

Hidden/fixed: Hidden in post analysis mode

  • Max bandwidth: contains the list of available frequency bandwidths in the selected signal file. This setting defines the largest frequency bandwidth for all the plug-in analyzers in the post-analysis mode.

Example:

Input 1 and Input 2 are the inputs to be recorded. Input 1 will be recorded with signal bandwidth = 20 kHz and Input 2 with signal bandwidth = 5 kHz.

Player connection wizard 10.png

In post analysis mode, the Player max bandwidth can be selected between 5 kHz and 20 kHz. Then, each Signal bandwidth group can be used in different plug-ins.

ON-LINE POST ANALYSIS
Recorded file Player Plug-in analyzer
Signal Bandwidth 1 Signal Bandwidth 2 Selected
Max Bandwidth
Plug-in analyzer x Plug-in analyzer y
Selected
Bandwidth
Available Input Selected
Bandwidth
Available Input
20 kHz 5 kHz 5 kHz 5 kHz #1 & #2
5 kHz #1 & #2
20 kHz 5 kHz 20 kHz 5 kHz #1& #2
20 kHz Only #1


The maximum available bandwidth for a plug-in analyzer depends on the Player max bandwidth selected. Then the inputs available in a plug-in are linked to the plug-in analyzer selected bandwidth. In the example above, the plug-in analyzer y selected bandwidth is 20 kHz. As the Player selected max bandwidth is 20 kHz, the Input 2 (signal bandwidth 2 = 5 kHz) cannot be analyzed at the frequency of 20 kHz.

  • Analysis mode: defines how the selected part of signal is analyzed in the post-analysis mode. Hidden/fixed: Visible in post analysis mode
Analysis mode Description
Continuous The selected part of the signal is played continuously.
Time step The player switches to pause every "Time step" second.


  • Time 'step': defines the time step in seconds in the "Time step" analysis mode. The player switches to "pause" every "time step" second. The user must then click on the "Player Continue" button to analyze the next "time step" signal duration.
Player connection wizard 11.png

Hidden/fixed: Visible in the post analysis mode

Tracks

Displays the list of the tracks contained in the selected signal file. The following settings are automatically adjusted at each signal file new selection.

  • Label: the name of the input signal recorded. Fixed
  • Transducer: the name of the transducer used during recording.
  • Physical qty.: the unit of the input signal selected during recording.
  • Sensitivity: the sensitivity of the transducer.
  • Range peak: the input range peak in the transducer SI unit. Fixed
  • Offset comp.: the input offset compensation in Volts.
Player connection wizard 12.png
  • Coupling: the input coupling. Fixed
  • Signal bandwidth: the equivalent signal frequency bandwidth and the corresponding sampling frequency (for example: 20 kHz (51.2 kS/s).

Filter: Allow you to put a filter on the player track. The player tracks can be connected to a plug-in analyzer in the Post-analysis mode or to the Front-end output in Connected mode on line. Fixed

Post analysis Video


@1mn27 exemple of post analysis on the signal