Properties

The properties are used as meta-data to enrich projects, models and measurements. They are informed while saving the items or by editing the properties from the project manager.

The properties belong to 3 different categories:

  • The OROS properties are automatically informed such as Dates, Author, Project and Saved results type
  • The OROS user properties are predefined to be informed by the user: Comments, Site, Installation, Intervention, Measurement type, UUT, Serial number
  • The Users properties are created and filled by the operator while saving or by editing the properties. Ex: Customer name, Transducer type

While saving data (Project, Model or Measurement) the save dialog box proposes the following layout (same for Project, Model and Measurement):

V10 release 05.png

On the left side the Item's name and the comments. Current Project and Model comments will inherit to the Measurements.

On the right side the OROS user and User properties. Current Project and Mode properties will inherit to the Measurements.


Saving Data: Enter properties values

To fulfill a property, click on the right cell of the corresponding line and add or edit text. To remove a property from the measurement, use the cross on the right side of the corresponding line.

V10 release 07.png

The user is given the possibility to fill in the content of a property from a drop-down list of predefined choices as shown in the window below:

Release note NVGate V12 10 16.png

Filling in a predefined choice for a property (when for example creating a new project)

Update measurement properties

To update the properties of an item (Remove, Add or Change values) open the item's contextual menu in the project manager and select Properties…

Manage properties

The properties visibility, behavior and association are managed through the properties manager. This is accessible form the NVGate ribbon: Home/Preferences/Properties manager

V10 release 11.png





How to proceed?

1. Start the properties manager window for the "Home ribbon"

Release note NVGate V12 10 17.png

Starting the properties manager window

2. After selecting a property, the property type can be selected. Three choices are available:

Free text: The user can enter any text freely when filling the property information.

List (restricted) (New in V12.10)

Fill-in the List items in the Properties manager. Then, when saving a project, a measurement or a setup the user will be able to select the item from a combo list as shown below.

List (New in V12.10):

This option is a mix of the "Free text" and "List (restricted)" option. During a save (measurement, setup or project), the list is proposed as a combo but free text still can be entered. For that the list items should be entered in the properties manager for the selected property. In this case, the property will be given the free text content but the list will not be populated with this new entry. If this is required, the list of that property can be modified in the properties manager.

Release note NVGate V12 10 18.png

Selecting the property LIST type during the properties management

  • Setting up the Default value for the property item.

For properties which are declared as list, it is possible to define their default value:

Release note NVGate V12 10 19.png

Setting up the default selection from the list

Multi-selecting to modify several properties at once

A user can simply select multiple properties to achieve an action (Modify behavior, Modify suggest or Delete) on all of them at once.

Release note NVGate V12 10 20.gif

Properties multi selection

Deleting existing properties
Release note NVGate V12 10 21.png

Deleting existing properties

The selected properties will be deleted from the database. The multi-selection enables to delete several properties at once.

Once deleted, the properties can still be shown using the "Show deleted properties" (Option accessible from the delete button using the down arrow. The property can be recovered by modifying the behavior to something other than "deleted" as shown from the window below.

Release note NVGate V12 10 22.png

Show deleted properties

Tips: 'How to completely reset your properties base? To achieve this you must delete the files "userPropertiesLibrary" and "userPropertyPolicies" which can be found at this location : C:\Users\Name\AppData\Local\OROS\NVGate

Managing the incoming properties

This feature allows a user to choose how to deal with properties coming from imported NVGate projects, measurements and models (after an import or a collate for example).

You can select what will happen to a property when the import occurs. The behavior is adjusted after pressing the button "Incoming …"

2 main choices are available: Import or Ignore

  • Import: When this behavior is selected, the user needs to select the following settings:
  • "behavior": apply to a new project, to a measurement, to a model, or don’t apply it (Nothing).
  • "suggest": empty, same as previous, same as today.

To update the properties for a team who use several PCs, select this option, then import a project, measurement, models on the PCs. The new properties will be including on the new PC, including combo list.

  • Ignore: When this behavior is selected, the property will actually take the status deleted right at the import level.
Release note NVGate V12 10 23.gif

Setting up what will happen to a property during an import

Sorting the properties

It is now possible to rank properties (after selecting them) to change their order:

Release note NVGate V12 10 24.png
  • Apply to new '''Item: will show the property while saving the corresponding Item
  • Nothing: The property will not be shown while saving any Item but will remain visible in the properties manager dialog.
  • Hidden: The corresponding property will behave as Nothing and will be hidden from the properties manager dialog. The Show all (3) check box will show hidden properties.

The suggest column (2) defines the value while saving the Item defined in the behavior column.

  • Empty: No suggestion
  • Same as previous: Allows changing the property content after multiple measurements Ex: n measurements per units in a set sequence of acquisitions.