Difference between revisions of "NVGate 2022: Release note"

From OROS Wiki
Jump to navigation Jump to search
Line 68: Line 68:
On the status bar you have now a direct access to the post analysis mode. Also this button allow you to know if the software is on onlime ode or post analysis mode.
On the status bar you have now a direct access to the post analysis mode. Also this button allow you to know if the software is on onlime ode or post analysis mode.


[[:File:PA_Status.png]]
[[File:PA_Status.png]]
 


====Automation====
====Automation====

Revision as of 10:30, 10 January 2022

Ergonomics

The interface gathers the analyzers functionalities in simple, clear and easy to identify tabs organized according to the main operations (Home, Acquisition, Analysis, Data, Display, Report, Automation, Preferences).


Tab: new icone disposition

Key features have been emphasized by interface, guiding the users to the best way using their OROS 3-Series analyzer. The software entries are organized in a logical operation way. There are 8 different tabs corresponding to the main operations type:

Home

Home3.PNG


The goal of the Home tab is to make a user friendly tab for doing a measurement. You can load a project, create a setup (using the "go to results" group), start an acquisition, see your data, the disk space and change the user. In fact for a lot of every day application you can stay on this tab, no need to check the other one.


we have also highlighted the Attachement function Home attachment 2022.PNG on this tab.


Attachment: Enables to quickly identify if files (reports, pictures, videos....) are attached to the current project. Click on this button to create and/or open the attachment folder. Note: if the "Default project" is active, the Attachment button is greyed.

Home attachment 2022.PNG The Attachment folder of the current project is empty or does not exist.
Home attachment file 2022.PNG File(s) are located in the Attachment folder of the current project.


Acquisition

This tab provides all the necessary entries to setup the front-end and the use of any channels in details. It separates the acquisition channels setup from the outputs, triggering, tachometer, and filters ones.

Acquisition3.PNG

Analysis

In this tab, the software gathers the front-end, recorder and analyses controls. Each icon corresponds to a plug-in analyzer. The content of this tab depends on the purchased optional plug-ins.
Analysis3.PNG

Data

This tab provides functions to deal all your data, transfer Projects, Measurements, Models, export and import your data, filter the Project Manager. Data3.PNG

Display

This tab covers the results display control. It allows creating, fulfilling, arranging and viewing the windows and layouts. It controls the scale, units, weighting and data operations of any graphs, manages the waterfalls and extraction graphs and the markers.

Display3.PNG

The display tab has been entirely thought and improved with NVGate 2022. Some functions have been highlighted : freeze, zoom, add layout. The mouse mode has been also improved (cursor, marker, zoom, move, rotate). One mode can now be selected in one click. Also now the default mouse mode will always be the cursor mode, so if you unselect a mode it will go back directly to the cursor mode.

Preferences

This tab provides direct access to the user’s definition, user's preferences and sensor database.

Preference3.PNG

Post analysis button on status bar

On the status bar you have now a direct access to the post analysis mode. Also this button allow you to know if the software is on onlime ode or post analysis mode.

PA Status.png

Automation

The Automation tab contains powerful and helpful tools to automate repetitive tasks made with the analyzers. Automation.PNG

Go to results - new: one click icons

New "one click" function have been added on the go to results for more user friendliness.

Gotoresults3.PNG


  • Viwe recording.PNGview recording: will open the signal monitoring window on top of the current layout. In the case of this window is already open in another layout, it swaps to this layout.
  • Add layout.PNG Add Layout: Creates a new layout. A dialog box used to name the new layout is displayed by clicking on the button. A new tab is created and selected, corresponding to the new layout.
  • Waterfall settings.PNG Opens the waterfall triggering dialog. This dialog allows selecting the trigger of by the waterfall plug-in (only available on profile and waterfall tab).

RPM buttons create automatic events

Auto rpm.PNG The RPM button has now beeing entierly redesigned. Apply this button will automatically put the waterfall trigger on delta RPM or periodic. This will make the setup of NVGate much more easier for a rotating or run up aplication. (only available on profile or waterfall tab)


In details this button will :

  • Create a Delta RPM event, source = the one activated in the "Tach.". Delta velocity : 10 RPM.
  • Create a Periodic event (0.5 sec)
  • Create a Combined event 1. mode: "Delta RPM OR Periodic 1"
  • Set waterfall Trigger to Combined event
  • Create of an RPM event (source = the one activated in the tach field)

New default settings

The default settings in NVGate have been updated to the ones below. With these default settings, you can do rotating analysis measurement directly. Be aware that if you load an exiting project, the settings will not be affected. You can also easily change these settings.

FFT Overlap: 66%

FFT lines: 3200

FFT Overall low freq : 2 Hz


SOA resolution: 1/8

SOA overlap: 5

SOA OVL lower order: 0.2


Event Delta RPM: Delta velocity 10 rpm

Waterfall Depth: 1000

Tachometer/RPM Profiles/Duration: 120 sec

New units available

Unit.PNG

Angular velocity: Hertz

Pressure: Pascal and Bar

Torsionnal velocity: RPM

NVGate reader mode

Use NVGate in reader mode : no need usb dongle or hardware.

Reader.PNG

Fractional tach : ratio over 100

Reports Tools Ribbons 356.png: Fractional tachometer: computes RPM speed for a non accessible shaft by using gear ratio setting. Adapted for gear boxes and transmissions. The ratio can now be set up to 100! (previously it was 2).

Used to define up to 4 fractional tachs using data from the tach or the Ext Tach.


Tacho ratio.png
  • Tach ratio: this is the ratio between the output angular speed and the input angular speed. This setting is defined by the product of 2 fractions: N1/D1 * N2/D2 where N1, D1, N2 and D2 are integer values. Tach.1 / Tach.2 ratio maximum value can be set up to 100.
Le100.png

Up to 3 real time: plug in SOA

OROS, leader on rotating vibration analysis, is the only one in the world to let you perform 3 real time synchronous order analysis at the same time (this is also available in post analysis).

3SOA.PNG

Add on : PV (pressure volume) diagram

How to use :

  • Define one (or more) channel as a pressure.
  • Add this channel into Sync. order (SOA) plug in.
  • On SOA plug in , average, domain, select: "Angular"
  • Open PV_Diagram.exe
  • Click on refresh (right click) in available results if you do not see anything.
  • Select the input.
  • Compute once will display the PV diagram base once based the last triggerd block.
  • "background computation, will continuously compute the diagram.


Windows 11 compatibility

Windows 11 logo.svg.png

This version is compatible and fully tested with the last version of Microsoft Windows 10 and new Microsoft version Windows 11.

Teamviewer V15 quick support

If you have any question for using your OROS analyzer, Teamviewer is a power full tool to take control of your PC and check together your question. NVGate 2022 include a the new version V15 of teamviwer .

Teamviwer.PNG

This version is available on your computer foler here: C:\OROS\NVGate data\Links\TeamViewerQS.exe . You can also donwload using this specific link : https://get.teamviewer.com/orosTV

NVDrive : Read Write NVGate properties (Project / Measurement)

NVDrive allows you to take control of the analyzer with command lines. New NVDrive commands have been added on the NVDrive toolkit to read, write and delete the properties of projects and measurements.

File:Get project properties.PNG

Bug fixing

  • 14133: Record with DC inputs doesn't work for some frequency samplings.
  • 14112: Double filter with HP @10HZ in TDA in post analyse: nothing is displayed.
  • 14102: Christmas tree with OR35TW is reproduce in a specific configuration.
  • 14166: Delete the last value from calibration history.
  • 14187: History transducer database can not be display on a japanese windows 10 PC.
  • 14190: Random Burst on Block Event.
  • 14130: "result selection windows": Lissajous graph is not display .
  • 14184: Wrong display of TDA table after copy graph .
  • 14210: OCT not possible to set a time constant below 20 ms.
  • 14219: Autorange is "Saving the working results".
  • 14286: Octave limited range of CPB filter is working strangely.
  • 14194: Octave LimitedRange And Reduce SamplingFreq crash NVGate
  • 14399: Impossible to compute EVHV Spatiogramme.
  • 14290: several Lissajous graphics - cursors are not linked together.
  • 14437: Error on NVDrive "NVGS_GetTrackNumberOfSample" Function with SBL > 2GB

Orbigate

Tach ratio over 100

Teamwork: compatibility with several OR3X