Difference between revisions of "NVGate 2021: Release note"
Line 134: | Line 134: | ||
= Add on : Human body vibration = | = Add on : Human body vibration = | ||
'''Standards compatible''': international standards ISO 5349, ISO 8041, ISO 2631-1 and ISO 2631-5.<br> | '''Standards compatible''': international standards about whole/body vibration including: ISO 5349, ISO 8041, ISO 2631-1 and ISO 2631-5.<br> | ||
'''Parameters compute''': VDV, MSDV, MTVV, Weighted raw, al(ISO 2631-5), D(ISO 2631-5) are available. RMS, Peak, Crest, peak-Peak, are also available in NVGate plug in. | '''Parameters compute''': VDV, MSDV, MTVV, Weighted raw, al(ISO 2631-5), D(ISO 2631-5) are available. RMS, Peak, Crest, peak-Peak, are also available in NVGate plug in. |
Revision as of 14:42, 20 November 2020
OROS always strives to be closer to its users and is carefully listening to needs and requests. This is why OROS is regularly releasing new version. Customers under contract automatically benefit from each release.
The NVGate® 2021 mlajor version is available from january 2021. This release of the OROS 3-Series analyzer’s software platform brings additional functionalities and brings significative performance improvements.
This release note describes the content of version 12.00, with operating details.
Compatibility: NVGate V12.00 is compatible with all OROS instruments that have not been discontinued. Depending on the hardware options and version, some instrument features may or may not be available.
Filter no limitation
Filter order
High pass and low pass
Butterworth - Chebyshev band pass - Chebyshev Stop-band ripple
Octave overall no limitation
Application
global level with filter
remove noise from spectrum
Listen signal with filter
Kinematik marker
kinematik marker follow FFT Tachometer
Database include on install
Dirct access to database
Documentation
All the documentation and help have been completely renew. We have put an online wiki-based documentation with video, mnual, application note, download.
This page is in free access and can be consult here https://wiki.oros.com/wiki/index.php/Home
Wiki
On line mode
We advice to be connected to internet to enjoy the new docvumentation page.
So If you are connected to Internet, now the following button will bring you to the NVGate wiki page.
https://wiki.oros.com/wiki/index.php/NVGate
Be aware than this wiki page have a powerful research button if you need to search any settings.
If you are using NVGate in another language than english, the wikipage will be open with /XX at the end (XX correspond to the unicode language.
Exemple if you are using NVgate in japanese, the help will bring you to the page : https://wiki.oros.com/wiki/index.php/NVGate/ja (==> ja is the internation japanese code)
Off line mode
If you are not connected to internet, we will open the NVGate.pdf manual wich is on folder Manuals on the install directory of NVGate.
Video
Oros have launch a youtube channels here :
We have include tutorial vidéo on this wiki, to help you to use the OROS software
DC simulated
The DC simulated allow you to inject up to 32 external DC channels in NVGate from external source (exemple : GPS, weather station, external can bus...). The frequency sampling is up to 15 sample / seconds. Thanks to the python developer toolkit, a developer can easily develop an interface to inject the value inside NVGate. The GPS and weather station below have been develop using the DC simulated.
This option is include with the reference ORNV-VI-DC (wich also include the Virtual input).
How to use:
on acquisiton Tab, select connect input, select the DC inputs and select the DC simulated channels.
This channels can be activate and be put inside recorder and/or waterfall like any other DC channels.
The settings Value (wich can be controlled by an external software) will change the value of the inputs.
The others DC simulated settings details are explain on the front end settings page.
GPS
compatibility :
Android phone
Navilock NL-602U
NVGate_DC_Simulated_Manager#GPS
Weather station
- manuel
- comaptibility davisinstruments weather station :
(need the 3 elements)
- 6322OV Wireless Vantage Pro2 Integrated Sensor Suite
- 6510USB WeatherLink Data Logger
miscelisnious
Calibration
DC Dynamical sensor y = ax+b calibration
It is now possible to calibrate a dynamical sensor in "DC" or "DC floating" coupling using 2 values, then the software will automatically compute sensitivity and offset to obtaine the "y = ax + b" formula.
For using it, first create a DC sensor on the sensor database. Then apply this sensor to a channels.
Now on the calibration part, you can calibrate it using 2 values. Then the software will automatically and apply the sensitivity and offset.
Remove a sensor from history
If you have done a mistake during a sensor calibration, you can now delete a value from calbration sensor historic.
You need to ho on historic , select the sensor, select the value that you need to delete , then click on remove.
Displaying Time in Zoomed signal
Add on : Human body vibration
Standards compatible: international standards about whole/body vibration including: ISO 5349, ISO 8041, ISO 2631-1 and ISO 2631-5.
Parameters compute: VDV, MSDV, MTVV, Weighted raw, al(ISO 2631-5), D(ISO 2631-5) are available. RMS, Peak, Crest, peak-Peak, are also available in NVGate plug in.
Signal fitering including:
Time weighting for the Z axis for whole-body measurement (ISO 2651-1) | |
Time weighting for the X and Y axis for whole-body measurement (ISO 2651-1) | |
Time weighting for the hand-arms measurement in any direction (ISO 5349-1) | |
Time weighting for motion sickness measurement in the vertical direction (ISO 2651-1) | |
Time weighting for the X axis for whole-body measurement (ISO 2651-1) | |
Time weighting for all rotational directions for whole-body measurement (ISO 2651-1) | |
Time weighting for the Z axis for head comfort measurement (ISO 2651-1) |
The whole body vibration is applicable from vehicles and workplace machines through a supporting surface. For hand hamr vibrationon we need specific sensors wich are installed on adapters for holding them on a handle or between fingers
Orbit display include on FFT diag or ORD diag
For customer with option FFT-Diag or ORD-Diag , they will now have the Orbit display available in NVGate.
The orbit is available using the add/remove windows.
For details check the orbit dipslay page.