The "Display/Graphs" tab
This tab covers the results display control. It allows creating, fulfilling, arranging and viewing the windows and layouts. It controls the scale, units, weighting and data operations of any graphs, manages the waterfalls and extraction graphs and the markers.
Windows group
This part of the display/graph tab manages the windows creation, their refreshment and the infotrace view/hide. See windows-graph page
Note: Clicking on the bottom right icon ( File:Reports Tools Ribbons 425.png ) opens active window properties dialog. The content of this dialog varies depending on the windows type. See properties page
Add/remove windows
Add/remove: Opens the add/remove windows dialog. This dialog allows creating and arranging the traces, graphs, windows and layouts. Layouts/windows/traces
- One tab is displayed for each layout. Each tab is made up of a tree showing the windows and results displayed in each window.
File:Reports Tools Ribbons 427.jpg
- Creates a new layout. A dialog box used to name the new layout is displayed by clicking on the button. A new tab is created and selected, corresponding to the new layout.
- Creates a new window, in the layout of the selected tab. A dialog box used to name the new window is displayed by clicking on the button.
- Adds the results selected in the window of the layout tab. If the layout does not contain any windows, a new window is created. A dialog box that shows the name of the new window is displayed. If a result is selected in the layout tab, a click on this button has no effect.
- Renames the window selected in the layout tab. If no window is selected, a click on this button has no effect and an error message is displayed in a message box.
- Deletes the selected window or trace selected in layout tab.
Plug-in analyzer tab: A tab is displayed for each plug-in analyzer connected.
- Result selection: List of results provided by the plug-in analyzer selected. Multiple plug-ins may be selected if all results selected are compatible (which means that they can be displayed in the same result window).
- Channel selection: List of plug-in analyzer channels connected, available for the result selected.
- Operation: in the top combo-box, list of weighting which can be applied to results selected. In the middle combo-box, list of derivation/integration operations which can be applied. In the bottom combo-box, list of display units.
- Reference / X: List of plug-in analyzer channels connected. This can be the reference. Available for results that require a reference only (cross-spectrum, for example).
- Tracked order: List of tracked orders on channel selected. Available if result selected is an order result.
Waterfall tab
- Analyzer result: The list of plug-in analyzers connected that provide Waterfall source results is displayed in the combo-box. The list of results provided by the plug-in analyzer selected, which can be a waterfall source is displayed in the list-box below.
- Channel selection: List of plug-in analyzer channel connected, available for the result selected.
- Operation: in the top combo-box, list of weighting which can be applied to the results selected is displayed. In the middle combo-box, a list of derivation/integration operations that can be applied is displayed. In the bottom combo-box, a list of display units is displayed.
- Reference / X: List of plug-in analyzer channels connected. This can be a reference. Available for results that require a reference only (cross-spectrum, for example).
- Tracked order: A list of tracked orders on the channel selected. Available if the result selected is an order result.
External result tab: The "Externals results" tab allows displays results saved in measurements.
- Measurement selection: List of measurements classified by project.
- Result selection: List of results saved in the measurement selected. Multiple selections are not available.
- Operation: in the top combo-box, list of weighting which can be applied to results selected. In the middle combo-box, list of derivation/integration operations which can be applied. In the bottom combo-box, list of display units.
Other function
The left button is a multi-action button that can be assigned to differnts functions. To assign a function, select the corresponding item in the drop list. Note, assigning a function will apply it.
Close all: Close all the windows in the active Layout
Open infotrace: Opens or close (toggle) the infotrace of the active windows. The infotrace contains the trace(s) identification, the cursor and marker values and the section data for the 3D waterfall windows. See chapter 2 –Display - § area for details
Refresh all: Force the refreshment of displayed data. Applies to all windows and all traces. Used in case of de synchronization between the hardware and the software.
Freeze trace (F10): Freeze/unfreeze (toggle) the traces of the active window.
Freeze all traces Freeze/unfreeze (toggle) all the displayed traces in the active Layout
Zoom group
Control the windows graphical zooms and auto-scaling.
Y Adjust (CTRL+A): Adjust the Y scale of all displayed graph in the active Layout. See chapter 2 –Display - § Display window/graph menu / Y zoom for details
X/Z Adjust (CTRL+Q): Adjust minimum and maximum values of the X or Z-scale so that every point on the axis is visible.. See chapter 2 –Display - § Display window/graph menu / X zoom for details
Reset scale (CTRL+Z): Reset the Y/X/Z scale of the active window. The default value of each scale depends on the inputs range for Y, The analysis bandwidth for X and the number of point for the Z one. See chapter 2 –Display - § Display window/graph menu for details
Zoom in Y: Makes the Y-scale two times smaller.
Zoom out Y: Makes the Y-scale tow time larger.
Zoom in X: Makes the X-scale two times smaller and sets the minimum and maximum values so that the cursor is in the middle of the graph.
Zoom out X: Makes the X-scale twice as large and sets the minimum and maximum values so that the cursor is in the middle of the graph.
View group
Browses the displayed windows and toggle the 3D/2D view
Cascade view: Toggle the active trace between 3D and 2D graphs. Applies to spectral (freq, order, 1/n oct) window only. Note the Cascade view is designed for monitoring purpose as it bufferize the data in the display. Buffered data cannot be manipulated or saved, use the waterfall plug for this purpose. See chapter 2 –Display - § Display window/window menu / Cascade view for details
Browse Windows (ALT+TAB): Scan the existing windows in the current layout.
Browse layouts (CTRL+SHIFT+SPACE): Scan the existing layouts. Note the 2 latest viewed layouts are kept in the RAM memory. Note: using the CTRL+SPACE shortcut allow switching between these layouts
Arrangement group
Full screen: Put the active windows in full screen mode. The NVGate frame windows will take the whole screen space. The full screen is inactivated by clicking on it or in reducing the window with the upper right button
Allows arranging automatically the windows in the current layout.
Automatic: Organizes windows in the best possible arrangement according to the type and contents of the graphs.
Cascade: Cascades the windows according to the Windows operating system rules.
Vertical: Tiles windows horizontally according to the Windows operating system rules.
Horizontal: Tiles windows horizontally according to the Windows operating system rules.
Grid: Tiles windows in order to have all windows with the same size.
File:Add layout.png Creates a new layout. A dialog box used to name the new layout is displayed by clicking on the button. A new tab is created and selected, corresponding to the new layout.
Marker group
Features a complete set of real-time markers that help identifying typical signature and points of exception in both time and spectral graphs.
See Marker page for more info.