Difference between revisions of "NVGate DSP computation SPU"

From OROS Wiki
Jump to navigation Jump to search
Line 2: Line 2:
SPU computation for normal DSP : OR34 V1 - Or35V1 - OR36V1 OR36V22 (normal DSP) - OR38V1 - OR38V2 (Normal DSP).
SPU computation for normal DSP : OR34 V1 - Or35V1 - OR36V1 OR36V22 (normal DSP) - OR38V1 - OR38V2 (Normal DSP).


 
Because of the linearity of the computation, we consider 1DSP = 12 SPU. This allow a simplification for the SPU computation.


==FFT==
==FFT==

Revision as of 14:53, 15 February 2022

Normal DSP

SPU computation for normal DSP : OR34 V1 - Or35V1 - OR36V1 OR36V22 (normal DSP) - OR38V1 - OR38V2 (Normal DSP).

Because of the linearity of the computation, we consider 1DSP = 12 SPU. This allow a simplification for the SPU computation.

FFT

Computation SPUs:

Bandwidth Fdec Resolution Envelope Zoom SPU/Channel
for Real-time
SPU/Channel
for non Real-time
20k 1 401 No No 1 0,5
10k 1 401 No No 0,5 0,25
Nk 1 401 No No =N/20 =N/40
10k 2 401 No No 1 1
5k 4 401 No No 0,8 0,6
2k 10 401 No No 0,6 0,6
1k 20 401 No No 0,5 0,6
Lower
than 1k
Higher
than 20
401 No No 0,5 0,5
20k 1 401 and
below
No No 1 0,5
20k 1 801 No No 1,25 0,5
20k 1 1601 No No 1,5 0,5
20k 1 3201 No No 2 0,5
20k 1 6401 No No 3 0,5
20k 1 401 No No 1 0,5
20k 1 401 No Yes 2 1,5
20k 1 401 No No 1 0,5
20k 1 401 Yes Yes 3 3



Fft sampling.png

SOA

Computation SPUs:

Bandwidth (Hz) Decimation factor Resolution SPU/Channel
20 k 1 401 3
10 k 1 401 1,5
N k 1 401 =(N*3)/20
10 k 2 401 2
5 k 4 401 1,3
2,5 k 8 401 1,1
1,25 k 16 401 0,9
625 32 401 0,8
313 64 401 0,7
156 128 401 0,6
78 256 401 0,6
20 k 1 401 and below 3
20 k 1 801 3,25


Order analysis 19.png

Sampling Frequency: set in Front-End/Inputs settings/Input sampling

FFT Bandwidth: set in FFTx/FFT analysis/range

==

Octave:

Bandwidth Fdec Reso SPU/Channel
for Real-time
25.6k 1 1/3rd 4
20k 1 1/3rd 3
12.8k 1 1/3rd 2
10k 1 1/3rd 1,5
20k 1 1/3rd 3,0
10k 2 1/3rd 2,0
5k 4 1/3rd 1,25
20k 1 1/1 1,5
20k 1 1/3rd 3
20k 1 1/12th 6
20k 1 1/24th 12


Octave 01.png

Sampling Frequency: set in Front-End/Inputs settings/Input sampling

1/N Oct Bandwidth: set in OCT/FFT analysis/range

OVA

Bandwidth SPU/Channel
for Real-time
25,6k 1,25
20k 1
12,8k 0,75
10k 0,5

The overall acoustic levels analysis requires 1 SPU per channel at 20 kHz bandwidth. The number of required SPUs is directly proportional to the analysis bandwidth (i.e. the sampling frequency divided by 2.56).


Advanced understanding of computation SPU for force DSP

Forget what you To understand the Force DSP computation. Let's explain on a more advanced way.

The