|
|
(5 intermediate revisions by one other user not shown) |
Line 1: |
Line 1: |
| ===Analyzer architecture=== | | ===Modes=== |
| ====On-Line acquisition synopsis====
| | Here are the different Operating and Analysis modes you can use with OR3X/NVGate. |
| The following synopsis presents the basic structure of the NVGate<sup></sup> multi analyzer architecture for real-time acquisition and analysis. In this mode, OR3X processes parallel analysis with all plug-in analyzers running at the same time (FFT, 1/n Octave, SOA, Recorder…).
| |
| The Front-end inputs may be connected to any plug-in analyzer through the channels. There are up to 32 (8 for OR34/OR35 analyzer) channels on each plug-in analyzer. Any input plug-in analyzer channel combination is allowed.
| |
|
| |
|
| | {|border="2" cellspacing="0" cellpadding="4" width="100%" |
| | | |
| | |colspan = "2"|Analysis Modes |
|
| |
|
| [[Image:REF-MAN_VOL1_Analyzer_Settings_Browser_wiki_partA_05.png|framed|none]]
| | |- |
| | |Operating modes |
| | |On-line |
| | |Post analysis |
|
| |
|
| | |- |
| | |<br>Connected<br> |
| | [[Image:Usersmanual_90.png|framed|none]] |
|
| |
|
| | | |
| | [[Image:Usersmanual_91.png|framed|none]] |
|
| |
|
| | | |
| | [[Image:Usersmanual_92.png|framed|none]] |
|
| |
|
| [[Image:REF-MAN_VOL1_Analyzer_Settings_Browser_wiki_partA_06.png|framed|none]] | | |- |
| | |<br>Office<br> |
| | [[Image:Usersmanual_93.png|framed|none]] |
|
| |
|
| | | |
| | [[Image:Usersmanual_94.png|framed|none]] |
|
| |
|
| | | |
| | [[Image:Usersmanual_95.png|framed|none]] |
|
| |
|
| The plug-in analyzers share general resources such as Filters, Events, Time windows, and Tachometers. These resources can be associated with any channel or plug-in analyzer with a centralized set of parameters: for example, by applying filter 1 to channel 1 to 8 of each plug-in analyzer and filter 2 to channels 9 to 16 you can modify filtering characteristics directly from the resource settings.
| | |- |
| | |<br>D-Rec (Optional) |
| | | |
| | [[Image:Usersmanual_96.png|framed|none]] |
|
| |
|
| The Filter builder provides general purpose filters for low pass, high pass, pass band, stop band and integration functions that apply to the time domain signals. For example: distributing Input I to channel 1 to 3, will provide simultaneous analysis of acceleration, velocity and displacement of an accelerometer by applying Integrator filter to channel 2 and double Integrator filter to channel 3.
| | |Not possible |
| The Time windows resources allow the modification of force and response weighting windows. For example: associating the force window with channel 1 and the Response window to the rest of channels allows the modification of response characteristics from a single set of parameters in the resource.
| |
|
| |
|
| The Event Definition resource is used to create an event that can start, stop and trigger plug-in analyzers acquisition. These events can be based on different criteria (DC level, RPM, time…) as well as on results computed by the Monitor (Kurtosis, RMS, DC…). For example: an event based on an input RMS level can be used to start and/or stop the FFT averaging and the Recorder simultaneously by connecting the event to the plug-in analyzer trigger sub-module.
| | |} |
|
| |
|
| The Waterfall module collects and synchronizes the results computed and provided by the different plug-in analyzers. These results are displayed in segments and can be sorted in relation to selectable references (Time, RPM, DC…). For example: while computing orders, it is possible to track these values by adding them and the Tachometer (the reference) to the Waterfall. You will then be able to display order profiles and switch the reference between time and RPM. It is then possible to add any new result (value or spectrum) or any reference (DC input, 2<sup>nd</sup> tach) to the Waterfall.
| | Note: You can see the current operating mode and some other information in the Status bar on the bottom of the NVGate Window: |
|
| |
|
| Using the <nowiki>’</nowiki>Setup<nowiki>’</nowiki> menu (see also VOL3 § "''Operation with Vision''") it is possible to guide you through connections of inputs, player tracks, output signals, event, filters or waterfall and display properties related.
| | ====On-line==== |
| ====Post Analysis synopsis==== | | This mode is available with the Office or the Connected operating mode. |
| In the Post analysis mode, the Front-end and Output signals are no longer available. The only source able to provide recorded time signals is the player.
| |
| Post analysis features exactly the same functions as the On-Line mode replacing the inputs by the Player tracks. The Player tracks are then connectable to the plug-in analyzer channels and can be used by the resources.
| |
| Post analysis processing can be performed on the DSP (Connected mode, only for OR36/OR38) as well as on the PC CPU (Office mode).
| |
|
| |
|
| In addition to the Post analysis, it is possible to split the recorded signal files (channels and duration) by re-recording selected channels and time segments in a new signal file.
| | The Connected operating mode is used to record the signal provided by the inputs and perform real-time analysis (FFT, 1:n Oct….). |
|
| |
|
| Post analysis processing time depends directly on the computation load. It may be faster or slower than the real-time analysis.
| | The Office operating mode means no instrument is connected. It is the most frequently used to set up and prepare projects and measurements. |
| Using the Post analysis accommodates larger requests in terms of computation power that cannot be achieved in real-time analysis.
| |
|
| |
|
| [[Image:REF-MAN_VOL1_Analyzer_Settings_Browser_wiki_partA_07.png|framed|none]]
| | ====Post analysis==== |
| | This mode is available with the Office or the Connected operating mode. It allows computing the saved signals (compute FFT analysis on a recorded signal for example). To use it from the '''Channels''' menu, select '''Post-analysis'''. You should have at least one recorded signal file on your OR3X or PC Hard Drive before using the Post-analysis mode. |
|
| |
|
| | The OR3X or the PC Hard Drive (according to your selection) sends the recorded signal through the Player module in order to display the signal on the screen. |
|
| |
|
| [[Image:REF-MAN_VOL1_Analyzer_Settings_Browser_wiki_partA_08.png|framed|none]]
| | The inputs are not accessible anymore; they are replaced by Tracks (find all the information about the recorded channels in the Player module). |
|
| |
|
| ===ASB (Analyzer Setting Browser)===
| | '''Note: '''In the post analysis mode, the Front-end is not available anymore. |
| The analyzer settings (front-end and analysis) are gathered in a tree called the Analyzer Setting Browser (ASB). The ASB window is shown/hidden from the ''Home'' tab / ''View'' group with the ''Workspace ''check box.
| |
|
| |
|
| | '''Tip: '''It is possible to re-record a recorded signal file residing on either the OR3X or PC Hard Drive using the Player module. |
|
| |
|
| | ====Connected==== |
| | This mode corresponds to the use of NVGate connected to instruments through the Ethernet link. This configuration uses the hardware resources (DSP<nowiki>’</nowiki>s and local hard disk) for On-line analysis as well as Post-analysis. |
|
| |
|
| | The available options in connected mode are set up in the instrument license key. The USB dongle license key is not requested to operate this mode. |
|
| |
|
| | ====Office==== |
| | Office mode uses exclusively the PC resources (CPU, hard disk) for post-analysis and result exploitation, with no connection to instrument. |
|
| |
|
| The ASB is designed to offer an exhaustive access to the analyzer settings. The standard access to the analyzer setup is offered in a more intuitive and simpler way with the general Vision interface (see Chapter 6) | | The available options in Office mode are set up in the USB dongle. The USB dongle license key is requested to operate this mode. |
| <u>The Modules:</u>
| |
| The main entries of the ASB consist of modules corresponding to the main analyzer functions.
| |
|
| |
|
| *
| | Both modes (Connected and Office) can be run simultaneously on different PCs allowing independent use of each license key (for example: On-Line acquisition and Office post-analysis). |
| [[Image:REF-MAN_VOL1_Analyzer_Settings_Browser_wiki_partA_09.png|framed|none]]
| |
|
| |
|
| [[Image:REF-MAN_VOL1_Analyzer_Settings_Browser_wiki_partA_10.png|framed|none]]
| | ====On-Line acquisition==== |
| The '''sources''' that acquire, store and play-back signals
| | The following synopsis presents the basic structure of the NVGate multi-analyzer architecture for real-time acquisition and analysis. In this mode, OR3X processes parallel analysis with all plug-in analyzers running at the same time (FFT, 1/n Octave, SOA, Recorder…). |
| *
| |
| [[Image:REF-MAN_VOL1_Analyzer_Settings_Browser_wiki_partA_11.png|framed|none]]
| |
| The '''resources''' that provide events, filters, weighting windows, and tachometers to the plug-in analyzers
| |
| *
| |
| [[Image:REF-MAN_VOL1_Analyzer_Settings_Browser_wiki_partA_12.png|framed|none]]
| |
| The '''plug-in''' analyzers that process independent analysis modes
| |
| *
| |
| [[Image:REF-MAN_VOL1_Analyzer_Settings_Browser_wiki_partA_13.png|framed|none]]
| |
| The '''Waterfall''' that synchronizes the results computed by the plug-ins
| |
| The ASB has a maximum depth of 3 levels: module, sub-module, and settings. In the case of multiple similar sub-modules (inputs for example), the sub-modules are arranged in collections.
| |
| For each module, this document provides an array that summarizes the available results with detailed information.
| |
| <u>The sub-modules:</u>
| |
| The modules contain the function and their setting functions.
| |
|
| |
|
| *
| | The Front-end inputs may be connected to any plug-in analyzer through the channels. There are up to 32 (8 for OR34/OR35 analyzer) channels on each plug-in analyzer. Any input plug-in analyzer channel combination is allowed. |
| [[Image:REF-MAN_VOL1_Analyzer_Settings_Browser_wiki_partA_14.png|framed|none]]
| |
| Sub-module = a function
| |
| *
| |
| [[Image:REF-MAN_VOL1_Analyzer_Settings_Browser_wiki_partA_15.png|framed|none]]
| |
| Inputs = incoming signals measured from the front-end
| |
| *
| |
| [[Image:REF-MAN_VOL1_Analyzer_Settings_Browser_wiki_partA_16.png|framed|none]]
| |
| Outputs = signals generated from the hardware
| |
| *
| |
| [[Image:REF-MAN_VOL1_Analyzer_Settings_Browser_wiki_partA_17.png|framed|none]]
| |
| Collection = A set of identical sub-modules (e.g; inputs, channels, events, ect..)
| |
| <u>The Settings:</u>
| |
|
| |
|
| The settings are the function<nowiki>’</nowiki>s parameters. There are multiple type of settings identified by specific icons:
| | [[Image:Usersmanual_97.png|framed|none]] |
|
| |
|
| *
| | The plug-in analyzers share general resources such as Filters, Events, Time windows and Tachometers. These resources can be associated with any channel or plug-in analyzer with a centralized set of parameters: for example, by applying filter 1 to channel 1 to 8 of each plug-in analyzer and filter 2 to channels 9 to 16 you can modify filtering characteristics directly from the resource settings. |
| [[Image:REF-MAN_VOL1_Analyzer_Settings_Browser_wiki_partA_18.png|framed|none]]
| |
| A scalar (integer or real) boundaries are displayed in the tooltip
| |
| *
| |
| [[Image:REF-MAN_VOL1_Analyzer_Settings_Browser_wiki_partA_19.png|framed|none]]
| |
| A list: the setting is one of the list items. Note: the list content may vary with the current configuration.
| |
| *
| |
| [[Image:REF-MAN_VOL1_Analyzer_Settings_Browser_wiki_partA_20.png|framed|none]]
| |
| A text e.g; the label of channel
| |
| *
| |
| [[Image:REF-MAN_VOL1_Analyzer_Settings_Browser_wiki_partA_21.png|framed|none]]
| |
| A signal. Usually a file containing signal(s)
| |
| *
| |
| [[Image:REF-MAN_VOL1_Analyzer_Settings_Browser_wiki_partA_22.png|framed|none]]
| |
| A check box. (e.g; mute/un-mute generator)
| |
| *
| |
| [[Image:REF-MAN_VOL1_Analyzer_Settings_Browser_wiki_partA_23.png|framed|none]]
| |
| An action. Temporary information. (e.g; a user event trigger)
| |
| *
| |
| [[Image:REF-MAN_VOL1_Analyzer_Settings_Browser_wiki_partA_24.png|framed|none]]
| |
| Special: multi-parameter setting (e.g; The tach ratio)
| |
| *
| |
| [[Image:REF-MAN_VOL1_Analyzer_Settings_Browser_wiki_partA_25.png|framed|none]]
| |
| Special: graphical multi-parameter setting (e.g; force/response weighting windows)
| |
| '''Note: ''' A setting may be informative, i.e, it is not possible to modify it. In such case an I is displayed close to the icon:
| |
| [[Image:REF-MAN_VOL1_Analyzer_Settings_Browser_wiki_partA_26.png|framed|none]]
| |
|
| |
|
| | The Filter builder provides general purpose filters for low pass, high pass, pass band, stop band, integration and differentiation functions that apply to the time domain signals. |
|
| |
|
| '''Note''': settings may be hidden or visible depending on the current configuration.
| | For example: distributing Input I to channel 1 to 3, will provide simultaneous analysis of acceleration, velocity and displacement of an accelerometer by applying Integrator filter to channel 2 and double Integrator filter to channel 3. |
|
| |
|
| ===Using the analyzer===
| | The Time windows resources allow the modification of force and response weighting windows. For example: associating the force window with channel 1 and the Response window to the rest of channels allows the modification of response characteristics from a single set of parameters in the resource. |
| ====Considerations for post-processing====
| |
| NVGate provides specialized modes that enable dedicated functionalities related to the application. By selecting specialized mode functionalities such as;
| |
|
| |
|
| | The Event Definition resource is used to create an event that can start, stop and trigger plug-in analyzers acquisition. These events can be based on different criteria (DC level, RPM, time…) as well as on results computed by the Monitor (Kurtosis, RMS, DC…). For example: an event based on an input RMS level can be used to start and/or stop the FFT averaging and the Recorder simultaneously by connecting the event to the plug-in analyzer trigger sub-module. |
|
| |
|
| [[Image:REF-MAN_VOL1_Analyzer_Settings_Browser_wiki_partA_02.png|framed|none]]
| | The Waterfall module collects and synchronizes the results computed and provided by the different plug-in analyzers. These results are displayed in segments and can be sorted in relation to selectable references (Time, RPM, DC…). For example: while computing orders, it is possible to track these values by adding them and the Tachometer (the reference) to the Waterfall. You will then be able to display order profiles and switch the reference between time and RPM. It is then possible to add any new result (value or spectrum) or any reference (DC input, 2nd tachometer) to the Waterfall. |
|
| |
|
| | ====Post analysis==== |
| | In the Post analysis mode, the Front-end and Output signals are no longer available. The only source able to provide recorded time signals is the player. |
|
| |
|
| If the time signal is recorded on the PC or on the Mobi-Disk<sup>™</sup>, it is highly recommended to be in office mode (hardware not connected) in order to avoid low performances and malfunctions.
| | [[Image:Usersmanual_98.png|framed|none]] |
| | |
| | |
| | |
| By selecting specialized mode functionalities such as;
| |
| * Availability of results
| |
| * Settings
| |
| * User preference,
| |
| will be enabled. Unselecting specialized mode will mask these functionalities. There are 2 specialized modes:
| |
| | |
| * '''Structural mode''': this mode is dedicated to the acquisition of modal data through hammer acquisition or signals provided by up to 6 shakers. The following topics are available when structural mode is active:
| |
| | |
| * Visibility of FRF (H1, H2) and Coherence results in FFT plug-ins.
| |
| * Visibility of time windows (force and response) in the ASB, and control panel.
| |
| * Availability of the inputs node settings in the inputs properties (ASB, Control Panel and Ribbon)
| |
| *
| |
| [[Image:REF-MAN_VOL1_Analyzer_Settings_Browser_wiki_partA_03.png|framed|none]]
| |
| | |
| | |
| Availability of accept/reject in the bottom right:
| |
| | |
| * '''Rotating mode''': this mode is dedicated to rotating and reciprocating machines. The following topics are available when rotating mode is active:
| |
| | |
| * FFT order extraction, constant band tracking or synchronous order.
| |
| * Tachometer settings.
| |
| * Plug-in analysis <nowiki>’</nowiki>Sync Order<nowiki>’</nowiki> will be unlocked.
| |
| | |
| '''Note''': these specialized modes can be selected (by default) in the user<nowiki>’</nowiki>s preferences.
| |
| ====Controls====
| |
| This section explains how to access the different controls contained in the ASB (settings, custom display...) and what they mean.
| |
| =====Access=====
| |
| There are 4 way to access a setting:
| |
| | |
| ======From the module======
| |
| The first access level is available by right clicking on a module (Front-end, Recorder, Tachometer, FFT...) and '''Properties''' where all the settings contained in this module can be adjusted.
| |
| | |
| ======From the collection======
| |
| The second access level is available by right clicking on a collection (Inputs, Outputs, Channels, Tracks...) and '''Properties''' where all the settings contained in this collection can be adjusted.
| |
| | |
| | |
| [[Image:REF-MAN_VOL1_Analyzer_Settings_Browser_wiki_partA_27.png|framed|none]]
| |
| | |
| | |
| It is also possible to copy and paste some items from a cell, a line, a column or a group of cell to another if they have compatible titles (Label, Transducer, Sensitivity…).
| |
| | |
| ======Copy/paste Front-end tables======
| |
| Taking advantages from the Excel capabilities for tables<nowiki>’</nowiki> creation and updating, NVGate V8.30 offers now to update the front-end/player tracks from Excel table.
| |
| | |
| This feature uses the Windows® clipboard.
| |
| | |
| | |
| [[Image:REF-MAN_VOL1_Analyzer_Settings_Browser_wiki_partA_28.png|framed|none]]
| |
| | |
| Two entries are made available from the contextual menu of the front-end or player tracks properties:
| |
| | |
| ''Copy to Clipboard'' and ''Paste from Clipboard. ''These commands come in addition to the local copy & paste which allows duplicating cells locally. Note that it is also available from any NVGate table.
| |
| | |
| Using the new ''Copy to'' ''clipboard'' capability allows pasting your inputs/track configuration to Excel, modifying it and then return it back in to NVGate. This also works with any spreadsheet software accepting csv content.
| |
| | |
| Generally, it works as a ''WYSIWYG'' (What You See Is What You Get); Data are exported in the same format/unit as displayed in NVGate table. Import (Paste into NVGate) behaves like you are typing the values.
| |
| | |
| Nevertheless, some precautions apply transferring data from Excel to NVGate:
| |
| | |
| * Headers (line and column) are added when pasting in Excel. This cell should not be copied prior to paste in NVGate.
| |
| * For the purpose of correct reading, units<nowiki>’</nowiki> columns are automatically added. These columns are ignored when pasting into NVGate. These columns may be absent from the Excel table.
| |
| * The figure (sensitivity, offset, etc...) units are read according to the current NVGate user preference one - <u>not</u> the units in the Excel table.
| |
| * Paste in NVGate starts from the upper-right cell of the area to update in the NVGate table. The cell should not be in editing mode.
| |
| * If pasted value is not acceptable for NVGate, the corresponding cell will:
| |
| * Adjust it to the closest upper value if it is possible (ex: max range)
| |
| * Ignore and keep the current one if not acceptable (ex: unknown coupling)
| |
| | |
| | |
| | |
| | |
| ======From the sub-module======
| |
| | |
| | |
| | |
| | |
| The third access level is available by right clicking on a sub-module (Input x, Output x, Track x, Channel x...) and '''Properties,''' where all the settings contained in this sub-module can be adjusted.
| |
| [[Image:REF-MAN_VOL1_Analyzer_Settings_Browser_wiki_partA_04.png|framed|none]] | |
| | |
| | |
| ======From the setting======
| |
| The fourth access level is available by right clicking on the setting itself (Label, Duration, Transducer, Coupling...) and '''Properties,''' where the new value for this setting can be entered.
| |
| | |
| | |
| [[Image:REF-MAN_VOL1_Analyzer_Settings_Browser_wiki_partA_29.png|framed|none]]
| |
| | |
| | |
| =====Contextual menu=====
| |
| Contextual menus appear when right clicking on an area or an item.
| |
| ======On an item======
| |
| Different controls are available according to the item you right click on.
| |
| * '''Properties:''' displays the properties of the item.
| |
| * '''Add/Remove: '''Available for collections (Channels, Event...), it enables or disables some items of the collection
| |
| | |
| | |
| | |
| | |
| | |
| * '''Set to default''': Reset a setting, a sub-module or a module to the default values. All connections are removed
| |
| * '''Copy (Ctrl<nowiki>+</nowiki>C)''': Copy a setting, a sub-module, or a module. This copy is internal and does not use the Clipboard
| |
| * '''Paste (Ctrl<nowiki>+</nowiki>V)''': Available when a copy action has been previously performed. Only the settings common to both the copy and the paste item are affected
| |
| * '''IDN ''''''info: '''Available only when the Shift key is pressed. It displays an identification number used by NVDrive<sup></sup>
| |
| * '''View state''': Available only on plug-ins, it hides or shows the status of this plug-in in the Status window
| |
| * '''Add to control panel''': Enable the corresponding setting to be modified from the Control Panel.
| |
| * '''dB''': Enable the corresponding setting to be displayed in dB. Only available for some scalar settings.
| |
| | |
| ======On ASB background======
| |
| * '''Auto width''': this function adjusts the width of the ASB.
| |
|
| |
|
| =====Plug-in analyzer status=====
| | Post analysis features exactly the same functions as the On-Line mode replacing the inputs by the Player tracks. The Player tracks are then connectable to the plug-in analyzer channels and can be used by the resources. Post analysis processing can be performed on the DSP (Connected mode, only for OR36/OR38) as well as on the PC CPU (Office mode). In addition to the Post analysis, it is possible to split the recorded signal files (channels and duration) by re-recording selected channels and time segments in a new signal file. |
| An icon is displayed in the ASB when a plug-in is connected. For each plug-in the icon displays the analysis status (running, stopped, recording...).
| |
| * '''Running '''
| |
| [[Image:REF-MAN_VOL1_Analyzer_Settings_Browser_wiki_partA_30.png|framed|none]]
| |
| : the plug-in analyzer is processing the data acquisition.
| |
| * '''Paused '''
| |
| [[Image:REF-MAN_VOL1_Analyzer_Settings_Browser_wiki_partA_31.png|framed|none]]
| |
| : the plug-in analyzer is paused. The plug-in analyzer is not processing any data. The user must click on the "continue" button to continue the analysis. For the recorder plug-in the "Continue" action starts a new record because in the paused state no data is recorded.
| |
| * '''Stopped'''
| |
| [[Image:REF-MAN_VOL1_Analyzer_Settings_Browser_wiki_partA_32.png|framed|none]]
| |
| : the plug-in analyzer is stopped.
| |
| * '''Recording'''
| |
| [[Image:REF-MAN_VOL1_Analyzer_Settings_Browser_wiki_partA_33.png|framed|none]]
| |
| : the plug-in recorder is processing the data acquisition.
| |
| * '''Block Triggering'''
| |
| [[Image:REF-MAN_VOL1_Analyzer_Settings_Browser_wiki_partA_34.png|framed|none]]
| |
| : the plug-in analyzer is waiting for the Trigger event to occur in order to process the data.
| |
| * '''Waiting'''
| |
| [[Image:REF-MAN_VOL1_Analyzer_Settings_Browser_wiki_partA_35.png|framed|none]]
| |
| : in the manual rejection mode, the plug-in analyzer is waiting for the user to accept or to reject the current analyzed signal block.
| |
| * '''Failure '''
| |
| [[Image:REF-MAN_VOL1_Analyzer_Settings_Browser_wiki_partA_36.png|framed|none]]
| |
| : the plug-in analyzer has failed (the analyzer is no longer able to compute the data acquisition; a warning message will appear)
| |
| =====Copy/Paste setting between plug-ins=====
| |
| By right clicking on any settings of the ASB you can Copy values of settings, and then Paste it anywhere else. There is an automatic type matching, which allows pasting only value of the same settings (using the IDN number).
| |
|
| |
|
| This Copy/Paste is available at each level of the ASB. This let you the opportunity of the multi-analysis in the same condition.
| | Post analysis processing time depends directly on the computation load. It may be faster or slower than the real-time analysis. Using the Post analysis accommodates larger requests in terms of computation power. This cannot be achieved in real-time analysis. |
|
| |
|
| For example you can see the same signal in the time domain and in the spectral domain, with exactly the same settings (for instance resolution). In the following example, the FFT1 have been set in the <nowiki>’</nowiki>Spectral domain<nowiki>’</nowiki>, with a specific range and a resolution. For the FFT2, right click on FFT2 and paste the setting from FFT1, then you have just to change the domain from spectral to time in that case.
| | If the time signal is located on the PC or on the Mobi-disk<sup>, </sup>it is highly recommended to be in office mode (no instrument connected) in order to avoid low performances and malfunctions. |
| You can compare the signal in, exactly, the same conditions.
| |
Modes
Here are the different Operating and Analysis modes you can use with OR3X/NVGate.
|
Analysis Modes
|
Operating modes
|
On-line
|
Post analysis
|
Connected
|
|
|
Office
|
|
|
D-Rec (Optional)
|
|
Not possible
|
Note: You can see the current operating mode and some other information in the Status bar on the bottom of the NVGate Window:
On-line
This mode is available with the Office or the Connected operating mode.
The Connected operating mode is used to record the signal provided by the inputs and perform real-time analysis (FFT, 1:n Oct….).
The Office operating mode means no instrument is connected. It is the most frequently used to set up and prepare projects and measurements.
Post analysis
This mode is available with the Office or the Connected operating mode. It allows computing the saved signals (compute FFT analysis on a recorded signal for example). To use it from the Channels menu, select Post-analysis. You should have at least one recorded signal file on your OR3X or PC Hard Drive before using the Post-analysis mode.
The OR3X or the PC Hard Drive (according to your selection) sends the recorded signal through the Player module in order to display the signal on the screen.
The inputs are not accessible anymore; they are replaced by Tracks (find all the information about the recorded channels in the Player module).
Note: In the post analysis mode, the Front-end is not available anymore.
Tip: It is possible to re-record a recorded signal file residing on either the OR3X or PC Hard Drive using the Player module.
Connected
This mode corresponds to the use of NVGate connected to instruments through the Ethernet link. This configuration uses the hardware resources (DSP’s and local hard disk) for On-line analysis as well as Post-analysis.
The available options in connected mode are set up in the instrument license key. The USB dongle license key is not requested to operate this mode.
Office
Office mode uses exclusively the PC resources (CPU, hard disk) for post-analysis and result exploitation, with no connection to instrument.
The available options in Office mode are set up in the USB dongle. The USB dongle license key is requested to operate this mode.
Both modes (Connected and Office) can be run simultaneously on different PCs allowing independent use of each license key (for example: On-Line acquisition and Office post-analysis).
On-Line acquisition
The following synopsis presents the basic structure of the NVGate multi-analyzer architecture for real-time acquisition and analysis. In this mode, OR3X processes parallel analysis with all plug-in analyzers running at the same time (FFT, 1/n Octave, SOA, Recorder…).
The Front-end inputs may be connected to any plug-in analyzer through the channels. There are up to 32 (8 for OR34/OR35 analyzer) channels on each plug-in analyzer. Any input plug-in analyzer channel combination is allowed.
The plug-in analyzers share general resources such as Filters, Events, Time windows and Tachometers. These resources can be associated with any channel or plug-in analyzer with a centralized set of parameters: for example, by applying filter 1 to channel 1 to 8 of each plug-in analyzer and filter 2 to channels 9 to 16 you can modify filtering characteristics directly from the resource settings.
The Filter builder provides general purpose filters for low pass, high pass, pass band, stop band, integration and differentiation functions that apply to the time domain signals.
For example: distributing Input I to channel 1 to 3, will provide simultaneous analysis of acceleration, velocity and displacement of an accelerometer by applying Integrator filter to channel 2 and double Integrator filter to channel 3.
The Time windows resources allow the modification of force and response weighting windows. For example: associating the force window with channel 1 and the Response window to the rest of channels allows the modification of response characteristics from a single set of parameters in the resource.
The Event Definition resource is used to create an event that can start, stop and trigger plug-in analyzers acquisition. These events can be based on different criteria (DC level, RPM, time…) as well as on results computed by the Monitor (Kurtosis, RMS, DC…). For example: an event based on an input RMS level can be used to start and/or stop the FFT averaging and the Recorder simultaneously by connecting the event to the plug-in analyzer trigger sub-module.
The Waterfall module collects and synchronizes the results computed and provided by the different plug-in analyzers. These results are displayed in segments and can be sorted in relation to selectable references (Time, RPM, DC…). For example: while computing orders, it is possible to track these values by adding them and the Tachometer (the reference) to the Waterfall. You will then be able to display order profiles and switch the reference between time and RPM. It is then possible to add any new result (value or spectrum) or any reference (DC input, 2nd tachometer) to the Waterfall.
Post analysis
In the Post analysis mode, the Front-end and Output signals are no longer available. The only source able to provide recorded time signals is the player.
Post analysis features exactly the same functions as the On-Line mode replacing the inputs by the Player tracks. The Player tracks are then connectable to the plug-in analyzer channels and can be used by the resources. Post analysis processing can be performed on the DSP (Connected mode, only for OR36/OR38) as well as on the PC CPU (Office mode). In addition to the Post analysis, it is possible to split the recorded signal files (channels and duration) by re-recording selected channels and time segments in a new signal file.
Post analysis processing time depends directly on the computation load. It may be faster or slower than the real-time analysis. Using the Post analysis accommodates larger requests in terms of computation power. This cannot be achieved in real-time analysis.
If the time signal is located on the PC or on the Mobi-disk, it is highly recommended to be in office mode (no instrument connected) in order to avoid low performances and malfunctions.