Difference between revisions of "NVGate Ribbons: Home"
Jump to navigation
Jump to search
(7 intermediate revisions by the same user not shown) | |||
Line 7: | Line 7: | ||
|-valign = "top" | |-valign = "top" | ||
|[[File:Home_start_2022.PNG|30px]] | |[[File:Home_start_2022.PNG|30px]] | ||
| '''Start...''': Opens the ''NVGate start'' dialog which is dedicated to make the first steps in the software. The ''NVGate start'' dialog is also displayed at each NVGate Start except if the user checks the option ''Do not show again'' in the dialog. | | '''Start...''': Opens the ''NVGate start'' dialog which is dedicated to make the first steps in the software. | ||
''Note: The ''NVGate start'' dialog is also displayed at each NVGate Start except if the user checks the option ''Do not show again'' in the dialog.'' | |||
[[File:NVGate_start_dialog_2022.JPG|400px]] | |||
{|border="0" cellspacing="0" cellpadding="4" width="30%" align="left" | |||
|-valign = "top" | |||
|[[File:Open_project_2022.JPG|30px]] | |||
| '''Open project''': Open an existing project. | |||
|-valign = "top" | |-valign = "top" | ||
|[[File: | |[[File:New_project_2022.JPG|30px]] | ||
| ''' | | '''New project''': Create a new project. | ||
|-valign = "top" | |-valign = "top" | ||
| | | | ||
| ''' | | '''Recent projects''': Recently opened projects. | ||
|}<br clear="all"> | |}<br clear="all"> | ||
Line 52: | Line 59: | ||
|- | |- | ||
|[[File:Home_select_signals_2022.PNG|30px]] | |[[File:Home_select_signals_2022.PNG|30px]] | ||
| '''Select signal''': | | '''Select signal''': Open the ''Select signal'' dialog to select the signal to be post-analyzed. | ||
|- | |- | ||
|[[File:Home_select_tracks_2022.PNG|30px]] | |[[File:Home_select_tracks_2022.PNG|30px]] | ||
| '''Select tracks''': | | '''Select tracks''': Open the ''Inputs'' table showing the inputs definition of the signal to be post-analyzed. | ||
|}<br clear="all"> | |}<br clear="all"> | ||
Line 81: | Line 88: | ||
|-valign = "top" | |-valign = "top" | ||
|[[File:Home_stop_2022.PNG|20px]] | |[[File:Home_stop_2022.PNG|20px]] | ||
| '''Stop''': (CTRL+S) | | '''Stop''': (CTRL+S) Stop all the current analyses and recording. After requesting a stop, the plug-ins finish their current block. When all the plug-ins have switched to Stop the analyzer switches to the Stopped status | ||
''Note: The analyzed results and recorded signal are saved when the analyzer switch to stop. This is the default behavior. It may be changed from the user preferences.'' | ''Note: The analyzed results and recorded signal are saved when the analyzer switch to stop. This is the default behavior. It may be changed from the user preferences.'' | ||
Line 103: | Line 110: | ||
===Save measurement=== | ===Save measurement=== | ||
Enables to save the results of a measurement. The results can be saved if: | |||
* There is at least one result selected in the save selection, | |||
* The analyzer is stopped, | |||
* The results exists. | |||
By default the save measurement displays the following confirmation window: | |||
[[File:Save_measurement_dialog_2022.JPG|500px]] | |||
The ''Save Measurement ''dialog shows the visible properties with their suggested value. | |||
This dialog box allows entering: | |||
* the measurement name to identify your data | |||
* An associated keyword that allows filtering the project manager | |||
* User<nowiki>’</nowiki>s comments (Use the CTRL<nowiki>+</nowiki>Enter to add lines) | |||
In Addition, the measurement can be informed with properties which are used to help retrieving the files and their meaning. | |||
The properties are attached to the measurement and filled while saving the data or by editing the properties from the project manager. The properties belong to 3 different categories: | |||
* The OROS properties are automatically filled by NVGate: Date, Author, Protection, Project name, Signal location and Number and type of saved results. | |||
* The OROS user properties are already created by NVGate. Their values, but must be filled by the operator: Comments, Site, Installation, Intervention, UUT, Serial number, Measurement type and Default type | |||
* The Users parameters are created and filled by the operator while saving or by editing the properties. Ex: ''TestCampaign'', ''R&DProject'' or ''Customer name''. Users parameters can be predefined from the ribbon: ''Measurement/Preferences/Measurement Properties'' | |||
Note that ''users<nowiki>’</nowiki> properties will pollinate''. It means the new properties type will be automatically added on the future measurements. The same occurs if you import or copy a measurement which contains unknown users<nowiki>’</nowiki> properties. | |||
The OROS User properties easily cover a wide range of situations. Properties options are: | |||
* Site is for the location of the measurement. It can be a ship, a test track, a test cell, an aircraft or a factory. | |||
* Installation is for the tested machinery. It can be a diesel engine, a car, a jet engine, a pump, a machine tool, etc… | |||
* Intervention describes the type of acquisition/analysis: qualification, overhaul check, prototyping, diagnostic, routine data collection, first run, etc… | |||
* Unit Under Test (UUT) indicates precisely which part is tested: a tire, a bearing, a transmission, etc… | |||
* Measurement type: Describes the type of measuring; Acoustic, diagnostic, rotating, etc.. | |||
* Default (or Defect): The identified defect on the UUT. | |||
Managing properties | |||
To enter the property values, click on the right cell of the corresponding line and add text. | |||
To remove a property from the measurement, use the cross on the right side of the corresponding line. | |||
To add a property fill the bottom left cell with the property name and use the tab or click on the right cell to enter its value. | |||
By right clicking on the property line you can hide it or change the suggestion mode. In order to save your entered values from one measurement to the next one, select ''Same as previous. '' ''Same as today'' will reset the suggestion as soon as the date of the latest saved measurement is different from current day. | |||
''Note: Measurement<nowiki>’</nowiki>s properties can be edited from the ''Project Manager'' by right clicking on the desired measurement.'' | |||
===Save option=== | ===Save option=== | ||
Line 184: | Line 237: | ||
|- | |- | ||
|[[File:Home_load_setup_2022.PNG|right|30px]] | |[[File:Home_load_setup_2022.PNG|right|30px]] | ||
| '''Load setup''': | | '''Load setup''': Open the ''Load setup'' dialog, which allows loading setups from Models, Measurements and Projects or creating setups for online or post-analysis. | ||
|- | |- | ||
|[[File:Home_save_as_model_2022.PNG|right|30px]] | |[[File:Home_save_as_model_2022.PNG|right|30px]] | ||
| '''Save as model''': | | '''Save as model''': Enable to save the current setup as a Model. | ||
|- | |- | ||
|[[File:Home_active_model_2022.PNG|right|100px]] | |[[File:Home_active_model_2022.PNG|right|100px]] | ||
| '''Active model''': | | '''Active model''': Display the name of the loaded Model. This Model will remain active until a ''Reset setup'' is applied or another setup is loaded. | ||
|- | |- | ||
|[[File:Home_reset_2022.PNG|right|30px]] | |[[File:Home_reset_2022.PNG|right|30px]] | ||
| '''Reset''': | | '''Reset''': Close the active Model and set all parameters to the default values. | ||
|}<br clear="all"> | |}<br clear="all"> | ||
Line 207: | Line 260: | ||
|-valign="top" | |-valign="top" | ||
|[[File:home_attachment_2022.PNG|30px]] | |[[File:home_attachment_2022.PNG|30px]] | ||
| '''Attachment''': | | '''Attachment''': Enable to quickly identify if files (reports, pictures, videos....) are attached to the current project. ''Note: if the "Default project" is active, the Attachment button is greyed. | ||
{|border="0" cellspacing="0" cellpadding="4" width="50%" align="left" | {|border="0" cellspacing="0" cellpadding="4" width="50%" align="left" | ||
|- | |- | ||
Line 219: | Line 272: | ||
|- | |- | ||
|[[File:Home_filter_projects_2022.PNG|30px]] | |[[File:Home_filter_projects_2022.PNG|30px]] | ||
| '''Filter projects''': | | '''Filter projects''': Open the ''Filter Project'' dialog, which enables selecting the projects to be visible in the ''Project manager''. | ||
|}<br clear="all"> | |}<br clear="all"> | ||
Line 229: | Line 282: | ||
|-valign = "top" | |-valign = "top" | ||
|[[File:Home_record_2022.PNG|right|150px]] | |[[File:Home_record_2022.PNG|right|150px]] | ||
| '''Record''': | | '''Record''': Display and enable selecting where the recording is performed (analyzer's disk or computer disk) or to stop temporarily the recording (off). | ||
|-valign = "top" | |-valign = "top" | ||
|[[File:used_space_2022.PNG|right|150px]] | |[[File:used_space_2022.PNG|right|150px]] | ||
| '''Used space''': | | '''Used space''': Give a visual overview of the space available on the disk. | ||
|-valign = "top" | |-valign = "top" | ||
|[[File:Download_2022.PNG|right|30px]] | |[[File:Download_2022.PNG|right|30px]] | ||
| '''Download''': | | '''Download''': Open the ''Mobi-Disk manager'' dialog, which lists the signals available on the analyzer's disk and enables selecting the signals to be downloaded on the pc. | ||
|}<br clear="all"> | |}<br clear="all"> |
Latest revision as of 18:45, 6 January 2022
Go to result group
Online mode
Start...: Opens the NVGate start dialog which is dedicated to make the first steps in the software.
Note: The NVGate start dialog is also displayed at each NVGate Start except if the user checks the option Do not show again in the dialog.
| |||||||
Online to Post-analysis: This button is used to switch from Online mode to Post-analysis mode. This will open the Select Signal window which lists all the recorded signals available. The selected signal will be then playback and can be re-injected into any plug-in analyzer (Monitor, FFT, 1/n Octave...). It is also possible to play back a recorded signal through the Output during Online analysis.
See player page for more details. | |||||||
Select inputs: Opens the Inputs selection dialog which allows activating and setting-up the dynamic inputs in a fast and smart way. | |||||||
Show results: Opens the Results dialog which allows displaying and saving results without connecting inputs or tracks to the plug-in analyzers in advance. | |||||||
Results overview: Opens the Results overview table which summarizes all the displayed and saved result (i.e. present in the Save Selection list) |
Post-analysis mode
Measurement group
Note that another Run/Pause/Stop button is always available in the status bar (bottom left)
Save group
Setup group
Load setup: Open the Load setup dialog, which allows loading setups from Models, Measurements and Projects or creating setups for online or post-analysis. | |
Save as model: Enable to save the current setup as a Model. | |
Active model: Display the name of the loaded Model. This Model will remain active until a Reset setup is applied or another setup is loaded. | |
Reset: Close the active Model and set all parameters to the default values. |
Data group
Attachment: Enable to quickly identify if files (reports, pictures, videos....) are attached to the current project. Note: if the "Default project" is active, the Attachment button is greyed.
| |||||
Filter projects: Open the Filter Project dialog, which enables selecting the projects to be visible in the Project manager. |
Disk group
Record: Display and enable selecting where the recording is performed (analyzer's disk or computer disk) or to stop temporarily the recording (off). | |
Used space: Give a visual overview of the space available on the disk. | |
Download: Open the Mobi-Disk manager dialog, which lists the signals available on the analyzer's disk and enables selecting the signals to be downloaded on the pc. |
User
User: This button allows selecting the current user. Note: changing from one user to another one will reset the current NVGate analysis configuration to the default one defined by the new user.