Difference between revisions of "NVGate Ribbons: Data"
(21 intermediate revisions by 2 users not shown) | |||
Line 1: | Line 1: | ||
[[category:NVGate]] | |||
[[File:Data_tab_2022.PNG|600px]] | [[File:Data_tab_2022.PNG|600px]] | ||
This tab provides functions to deal all your data, transfer Projects, Measurements, Models, export and import your data, filter the Project Manager. | |||
==Start== | ==Start== | ||
Line 30: | Line 33: | ||
[[File:Data_dataset_2022.PNG|120px]] | [[File:Data_dataset_2022.PNG|120px]] | ||
{|border="0" cellspacing="0" cellpadding="4" width=" | {|border="0" cellspacing="0" cellpadding="4" width="80%" align="left" | ||
|- | |- | ||
|[[File:collate_2022.PNG|30px]] | |[[File:collate_2022.PNG|30px]] | ||
| '''Collate''': | | '''Collate''': Enable to copy or move Projects / Measurements / Models from a specified source to the current Projects database. | ||
|- | |- | ||
|[[File:Share_2022.PNG|30px]] | |[[File:Share_2022.PNG|30px]] | ||
| '''Share''': | | '''Share''': Enable to copy or move Projects / Measurements / Models from the current Projects database to a specified target. | ||
|}<br clear="all"> | |||
See [[NVGate_dataset_management#Share_and_collect_dataset|Share and collect dataset]] for details. | |||
{|border="0" cellspacing="0" cellpadding="4" width="80%" align="left" | |||
|- | |- | ||
|[[File:Import_2022.PNG|30px]] | |[[File:Import_2022.PNG|30px]] | ||
| '''Import''': Import Signals and/or results files. See [[NVGate_Export/import#Import_Files|Export/import]] for | | '''Import''': Import Signals and/or results files. See [[NVGate_Export/import#Import_Files|Export/import]] for details. | ||
|}<br clear="all"> | |}<br clear="all"> | ||
Line 53: | Line 60: | ||
|- | |- | ||
|[[File:Data_filter_projects_2022.PNG|30px]] | |[[File:Data_filter_projects_2022.PNG|30px]] | ||
|'''Filter projects''': | |'''Filter projects''': Open the ''Filter projects'' dialog, which allows selecting the projects to be visible in the Project Manager. | ||
|- | |- | ||
|[[File:Data_edit_measurement_2022.PNG|30px]] | |[[File:Data_edit_measurement_2022.PNG|30px]] | ||
|'''Edit measurement''': | |'''Edit measurement''': Allow reviewing the measurements for comparison, modification or report. An edited measurement comes as a foreground layer on the top of the current analysis one. See [[NVGate_Edit_Measurement|edit measurement]] for details. | ||
|}<br clear="all"> | |}<br clear="all"> | ||
Line 65: | Line 72: | ||
PC and Mobi-Disc management tools | PC and Mobi-Disc management tools | ||
[[ | [[File:Data_Disk_group_2022.PNG|200px]] | ||
{|border="0" cellspacing="0" cellpadding="4" width="100%" align="center" | |||
|-valign="top" | |||
|[[File:Reports_Tools_Ribbons_242.png|70px]] | |||
|'''Active Disk''': Select the active disk. The active disk is the one which is mapped by the project manager. The disk where a signal file is located must be the active one in order to load it on the player (play back, post-process, exploration). | |||
The active disk can be: | The active disk can be: | ||
{|border="0" cellspacing="0" cellpadding="4" width="100%" align="center" | |||
|-valign="top" | |||
|[[File:Reports_Tools_Ribbons_243.png|30px]] The PC one. Available in office mode only. | |||
|-valign="top" | |||
|[[File:Reports_Tools_Ribbons_244.jpg|30px]] One of the Mobi-disk connected through a USB cable. Available in office mode only. | |||
|-valign="top" | |||
|[[File:Reports_Tools_Ribbons_245.jpg|30px]] The Analyzer disk (Mobi-Disk or fixed). Available in connected mode only. | |||
|}<br clear="all"> | |||
|-valign="top" | |||
|[[File:Data_manage_2022.PNG|30px]] | |||
| '''Manage''': Open the [[Disk(Hard-drive)_management#Disks_manager|disk manager]] in order to manage the signal files saved on it. | |||
|-valign="top" | |||
|[[File:Data_format_2022.PNG|30px]] | |||
| '''Format''': Format the active disk. Not available when PC disk is selected. | |||
''Warning: all saved data on the formatted disk will be definitely deleted''. | |||
|-valign="top" | |||
|[[File:Data_download_2022.PNG|30px]] | |||
| '''Download''': Select available signal file on the active disk that match the project present on the project manager. To recover signal files from a record session made with another PC use the manage button. | |||
|}<br clear="all"> | |||
==OR10 setup== | ==OR10 setup== | ||
[[File:data_OR10_setup.PNG|100px]] | |||
{|border="0" cellspacing="0" cellpadding="4" width="80%" align="left" | |||
|- | |||
|[[File:data_OR10_add_current.PNG|30px]] | |||
| '''Add current''': Add the current setup to the OR10 or generate a file to be copied on the OR10 µSD card. | |||
|- | |||
|[[File:data_OR10_list.PNG|30px]] | |||
| '''List''': Open the ''OR10 templates management'' dialog, which lists all the setups available on the OR10. | |||
|}<br clear="all"> | |||
==D-rec== | ==D-rec== | ||
This group manages D-rec (Direct recording) setups. D-rec allows recording signals with the analyzer without any PC or connection.<br> | This group manages D-rec (Direct recording) setups. D-rec allows recording signals with the analyzer without any PC or connection.<br> | ||
[[NVGate_D-Rec| | |||
[[File:Data_D_rec_setup_2022.PNG|80px]] | |||
{|border="0" cellspacing="10" cellpadding="0" width="100%" align="left" | |||
|- | |||
|[[File:data_new_d_rec.PNG|40px]] | |||
| '''New''': Propose a set of dialog boxes that guide the user through the necessary settings to build a D-rec setup. | |||
|- | |||
|[[File:data_list_d_rec.PNG|40px]] | |||
| '''List''': Open the ''Record setup management'' dialog which allows managing the setups saved in the analyzer. The D-rec setups can be written, removed, imported and exported from this dialog. | |||
|}<br clear="all"> | |||
Read [[NVGate_D-Rec|D-rec]] dedicated page for details. |
Latest revision as of 09:01, 13 January 2022
This tab provides functions to deal all your data, transfer Projects, Measurements, Models, export and import your data, filter the Project Manager.
Start
Start…: Opens the NVGate start dialog which is dedicated to make the first steps in the software. The NVGate start dialog is also displayed at each NVGate Start, except if the user checks the option Do not show again" in the dialog.
While launching NVGate or click on this button, operator is invited to select or create a project. This step allows reloading or defining the context.
Open Project
Selecting Open project opens the Open Project dialog which behaves as the single Item selection.
Select your project and click Open button.
New Project
Selecting New project opens the following dialog:
Fulfill the necessary properties and comment to describe the context of this project and click on OK button. This bring you to the setup selection.
Dataset
See Share and collect dataset for details.
Import: Import Signals and/or results files. See Export/import for details. |
Projects
Filter projects: Open the Filter projects dialog, which allows selecting the projects to be visible in the Project Manager. | |
Edit measurement: Allow reviewing the measurements for comparison, modification or report. An edited measurement comes as a foreground layer on the top of the current analysis one. See edit measurement for details. |
Disk
PC and Mobi-Disc management tools
Active Disk: Select the active disk. The active disk is the one which is mapped by the project manager. The disk where a signal file is located must be the active one in order to load it on the player (play back, post-process, exploration).
The active disk can be:
| ||||
Manage: Open the disk manager in order to manage the signal files saved on it. | ||||
Format: Format the active disk. Not available when PC disk is selected.
Warning: all saved data on the formatted disk will be definitely deleted. | ||||
Download: Select available signal file on the active disk that match the project present on the project manager. To recover signal files from a record session made with another PC use the manage button. |
OR10 setup
Add current: Add the current setup to the OR10 or generate a file to be copied on the OR10 µSD card. | |
List: Open the OR10 templates management dialog, which lists all the setups available on the OR10. |
D-rec
This group manages D-rec (Direct recording) setups. D-rec allows recording signals with the analyzer without any PC or connection.
Read D-rec dedicated page for details.