NVGate features a complete set of real-time markers that help identifying typical signature and points of exception in both time and spectral graphs.  
NVGate features a complete set of real-time markers that help identifying typical signature and points of exception in both time and spectral graphs.  
 
===Marker description===  
===Introduction===  
The marker group allows selecting and positioning the chosen marker. The markers allow quantifying measurement behaviors such as the band power between 2 frequencies, track signal harmonics or tracking the max amplitude of a signal…
The marker group allows selecting and positioning the chosen marker. The markers allow quantifying measurement behaviors such as the band power between 2 frequencies, track signal harmonics or tracking the max amplitude of a signal…


Line 14: Line 11:
[[Image:Display_Graphs_Traces_137.png|framed|none]]
[[Image:Display_Graphs_Traces_137.png|framed|none]]


 
====Free marker====
 
 
====Free====
*  
*  
[[Image:Reports_Tools_Ribbons_457.png|framed|none]]
[[Image:Reports_Tools_Ribbons_457.png|40 px|none]] Switch the cursor to deposit a free marker in the click location. The free marker can be positioned everywhere to add a legend in a spectra, profile, 1/n octave and waterfall section.
Free marker:  Switch the cursor to deposit a free marker in the click location. The free marker can be positioned everywhere to add a legend in a spectra, profile, 1/n octave and waterfall section.


When available, a free marker can be placed and moved within a graph to track specific values. A label can be associated with each free marker.
When available, a free marker can be placed and moved within a graph to track specific values. A label can be associated with each free marker.
Line 26: Line 19:
Right clicking on a free maker displays menu including "Properties", which opens edit free maker dialog box.
Right clicking on a free maker displays menu including "Properties", which opens edit free maker dialog box.


 
[[Image:Display_Graphs_Traces_03.png|400px|none]]
 
=====Free marker properties=====
 
[[Image:Display_Graphs_Traces_03.png|framed|none]]


* Label: The label associated with the marker. The user can enter directly a name or pick <nowiki>’</nowiki>display current position<nowiki>’</nowiki> to display automatically the coordinates of the selected point.
* Label: The label associated with the marker. The user can enter directly a name or pick <nowiki>’</nowiki>display current position<nowiki>’</nowiki> to display automatically the coordinates of the selected point.
Line 42: Line 31:
* X & Y: x and y interpolations are active.
* X & Y: x and y interpolations are active.


[[Image:Display_Graphs_Traces_138.png|framed|none]]
[[Image:Display_Graphs_Traces_138.png|500px|none]]


When the interpolation function is active, the interpolated value is preceded by a "i".
When the interpolation function is active, the interpolated value is preceded by a "i".
Line 54: Line 43:
----
----


====Harmonic====
====Harmonic marker====


*  
*  
[[Image:Reports_Tools_Ribbons_458.png|framed|none]]
[[Image:Reports_Tools_Ribbons_458.png|40px|none]] Switch the cursor to deposit a set of harmonics in the click location. The harmonic marker can be positioned everywhere in a spectra and waterfall X/Y sections.
Harmonic marker:  Switch the cursor to deposit a set of harmonics in the click location. The harmonic marker can be positioned everywhere in a spectra and waterfall X/Y sections.


Computes and displays harmonic values for the selected trace(s).
Computes and displays harmonic values for the selected trace(s).


[[Image:Display_Graphs_Traces_139.png|framed|none]]
[[Image:Display_Graphs_Traces_139.png|500px|none]]


=====Harmonic marker properties=====
'''Harmonic marker properties'''


[[Image:Display_Graphs_Traces_140.png|framed|none]]
[[Image:Display_Graphs_Traces_140.png|500px|none]]


* Harmonic visibility: Harmonics checklist. Only checked harmonics will be displayed.
* Harmonic visibility: Harmonics checklist. Only checked harmonics will be displayed.
Line 75: Line 63:
* X&Y: x and y interpolations are active.
* X&Y: x and y interpolations are active.


[[Image:Display_Graphs_Traces_141.png|framed|none]]
[[Image:Display_Graphs_Traces_141.png|500px|none]]


When the interpolation function is active, the interpolated value is preceded by a "i".
When the interpolation function is active, the interpolated value is preceded by a "i".


Note: the interpolated values of harmonic markers will be available only if the harmonic marker is placed on a peak.
''Note: the interpolated values of harmonic markers will be available only if the harmonic marker is placed on a peak.''


* Apply to
* Apply to
Line 87: Line 75:
----
----


====Peak====
====Peak marker====


*  
*  
[[Image:Reports_Tools_Ribbons_459.png|framed|none]]
[[Image:Reports_Tools_Ribbons_459.png|40px|none]] Switch the cursor to add a set of peak detection markers in the clicked graph. The peak marker detects automatically the peaks in the spectra and waterfall X/Y sections.
Peaks marker:  Switch the cursor to add a set of peak detection markers in the clicked graph. The peak marker detects automatically the peaks in the spectra and waterfall X/Y sections.


Computes and displays peak values for the selected trace(s).
Computes and displays peak values for the selected trace(s).
Line 102: Line 89:
[[Image:Display_Graphs_Traces_142.png|framed|none]]
[[Image:Display_Graphs_Traces_142.png|framed|none]]


=====Peak marker properties=====
'''Peak marker properties'''


* Threshold: In the example below, the "Threshold" is 10 dB.
* Threshold: In the example below, the "Threshold" is 10 dB.


[[Image:Display_Graphs_Traces_143.png|framed|none]]
[[Image:Display_Graphs_Traces_143.png|700px|none]]


* Ignore under: Does not display the detected peak if the peak is under this value. In the example below, the "ignore under" value is –15 dB.
* Ignore under: Does not display the detected peak if the peak is under this value. In the example below, the "ignore under" value is –15 dB.


[[Image:Display_Graphs_Traces_144.png|framed|none]]
[[Image:Display_Graphs_Traces_144.png|700px|none]]


* Number of peak: Number of peaks to be displayed. That will first display the greatest peaks.
* Number of peak: Number of peaks to be displayed. That will first display the greatest peaks.
Line 128: Line 115:


:
:
[[Image:Display_Graphs_Traces_146.png|framed|none]]
[[Image:damping_ratio.png|500px|none]]


The calculation of the damping factor is activated through the marker properties or preferences.
The calculation of the damping factor is activated through the marker properties or preferences.
Line 135: Line 122:
When it is activated an additional column is added in the corresponding marker table. The marker table can be saved in an MS Office document or simply copied and pasted.
When it is activated an additional column is added in the corresponding marker table. The marker table can be saved in an MS Office document or simply copied and pasted.


[[Image:Display_Graphs_Traces_147.png|framed|none]]
[[Image:Display_Graphs_Traces_147.png|600px|none]]


Warning, using nonhomogeneous weighting windows (i.e.: equivalent noise bandwidths are not the same) on FRF channels leads to incorrect peak interpolation and damping results.
Warning, using nonhomogeneous weighting windows (i.e.: equivalent noise bandwidths are not the same) on FRF channels leads to incorrect peak interpolation and damping results.


====Max====
====Max marker====
*  
*  
[[Image:Reports_Tools_Ribbons_460.png|framed|none]]
[[Image:Reports_Tools_Ribbons_460.png|40px|none]] Switch the cursor to add a set of maximum detection markers in the clicked graph. The max marker detects automatically the maximum in the spectra and waterfall X/Y sections.
Max marker:  Switch the cursor to add a set of maximum detection markers in the clicked graph. The max marker detects automatically the maximum in the spectra and waterfall X/Y sections.
Computes and displays max values for the selected trace(s).
Computes and displays max values for the selected trace(s).


A maximum is defined as a local maximum such that the variation in size of spectral density of ray, in relation to other local maximum surrounding it, is greater than a set threshold
A maximum is defined as a local maximum such that the variation in size of spectral density of ray, in relation to other local maximum surrounding it, is greater than a set threshold


[[Image:Display_Graphs_Traces_148.png|framed|none]]
[[Image:Display_Graphs_Traces_148.png|500px|none]]


=====Max marker properties=====
'''Max marker properties'''


[[Image:Display_Graphs_Traces_149.png|framed|none]]
[[Image:Display_Graphs_Traces_149.png|400px|none]]


* Hystersis
* Hystersis


[[Image:Display_Graphs_Traces_150.png|framed|none]]
[[Image:Display_Graphs_Traces_150.png|500px|none]]


* Ignore under: Does not display the detected peak if the peak is under this value. In the example below, the "ignore under" value is –15 dB.
* Ignore under: Does not display the detected peak if the peak is under this value. In the example below, the "ignore under" value is –15 dB.


[[Image:Display_Graphs_Traces_151.png|framed|none]]
[[Image:Display_Graphs_Traces_151.png|500px|none]]


* Number of max: Number of max to be displayed. That will first display the greatest max.
* Number of max: Number of max to be displayed. That will first display the greatest max.
Line 167: Line 153:
* X & Y: x and y interpolations are active.
* X & Y: x and y interpolations are active.


[[Image:Display_Graphs_Traces_152.png|framed|none]]
[[Image:Display_Graphs_Traces_152.png|500px|none]]


When the interpolation function is active, the interpolated value is preceded by a "i".
When the interpolation function is active, the interpolated value is preceded by a "i".
Line 176: Line 162:
* Damping ratio damping ratio is calculated for each detected Maximum. The calculation is based on the Half-power-band-width method, where DR is the damping ratio:
* Damping ratio damping ratio is calculated for each detected Maximum. The calculation is based on the Half-power-band-width method, where DR is the damping ratio:


[[Image:Display_Graphs_Traces_153.png|framed|none]]
[[Image:damping_ratio.png|500px|none]]


The calculation of the damping factor is activated through the marker properties or preferences.
The calculation of the damping factor is activated through the marker properties or preferences.
Line 182: Line 168:
When it is activated an additional column is added in the corresponding marker table. The marker table can be saved in an MS Office document or simply copied and pasted.
When it is activated an additional column is added in the corresponding marker table. The marker table can be saved in an MS Office document or simply copied and pasted.


[[Image:Display_Graphs_Traces_154.png|framed|none]]
[[Image:Display_Graphs_Traces_154.png|600px|none]]


Warning, using nonhomogeneous weighting windows (i.e.: equivalent noise bandwidths are not the same) on FRF channels leads to incorrect peak interpolation and damping results.
Warning, using nonhomogeneous weighting windows (i.e.: equivalent noise bandwidths are not the same) on FRF channels leads to incorrect peak interpolation and damping results.


====Side band====
====Side band marker====
*  
*  
[[Image:Reports_Tools_Ribbons_461.png|framed|none]]
[[Image:Reports_Tools_Ribbons_461.png|40px|none]] Switch the cursor to add a side band marker at the clicked location. The Sideband marker can be positioned everywhere in a spectra and waterfall X/Y sections
Side band marker:  Switch the cursor to add a side band marker at the clicked location. The Sideband marker can be positioned everywhere in a spectra and waterfall X/Y sections


Displays values for a central frequency and side frequencies (left and right) defined by a delta value.
Display values for a central frequency and side frequencies (left and right) defined by a delta value.


The management of side band markers selects the assumed porter and the first side band of modulation. The position of the cursor during the selection of the porter or the first side band is previously interpolated on the frequency axis, taking into account the frequency response of the weighting window used if the Interpolation setting allows this
The management of side band markers selects the assumed porter and the first side band of modulation. The position of the cursor during the selection of the porter or the first side band is previously interpolated on the frequency axis, taking into account the frequency response of the weighting window used if the Interpolation setting allows this
Line 197: Line 182:
[[Image:Display_Graphs_Traces_155.png|framed|none]]
[[Image:Display_Graphs_Traces_155.png|framed|none]]


=====Side band marker properties=====
'''Side band marker properties'''


[[Image:Display_Graphs_Traces_156.png|framed|none]]
[[Image:Display_Graphs_Traces_156.png|400px|none]]


* Start: Central value.
* Start: Central value.
Line 209: Line 194:
* X & Y: x and y interpolations are active.
* X & Y: x and y interpolations are active.


[[Image:Display_Graphs_Traces_157.png|framed|none]]
[[Image:Display_Graphs_Traces_157.png|500px|none]]


When the interpolation function is active, the interpolated value is preceded by a "i".
When the interpolation function is active, the interpolated value is preceded by a "i".
Line 219: Line 204:
** Associated with: the marker is associated with only one trace of the graph. If active is selected, the marker is applied to the current active trace of the graph.
** Associated with: the marker is associated with only one trace of the graph. If active is selected, the marker is applied to the current active trace of the graph.


====Power band====
====Power band marker====


*  
*  
[[Image:Reports_Tools_Ribbons_462.png|framed|none]]
[[Image:Reports_Tools_Ribbons_462.png|40px|none]] Switch the cursor to add a power band marker at the clicked location. The power-band marker can be positioned everywhere in a spectra and waterfall X/Y sections. It extracts the RMS power in the selected band taking in account the equivalent bandwidth of the weighting window.
Power band marker:  Switch the cursor to add a power band marker at the clicked location. The power-band marker can be positioned everywhere in a spectra and waterfall X/Y sections. It extracts the RMS power in the selected band taking in account the equivalent bandwidth of the weighting window.


Computes and displays power in signal range defined by start position and delta.
Computes and displays power in signal range defined by start position and delta.


[[Image:Display_Graphs_Traces_158.png|framed|none]]
[[Image:Display_Graphs_Traces_158.png|600px|none]]


=====Power band marker properties=====
'''Power band marker properties'''


[[Image:Display_Graphs_Traces_159.png|framed|none]]
[[Image:Display_Graphs_Traces_159.png|400px|none]]


* Start: Start value for the power band computation.
* Start: Start value for the power band computation.
Line 239: Line 223:
** Associated with: the marker is associated to only one trace of the graph. If active is selected, the marker is applied to the current active trace of the graph.
** Associated with: the marker is associated to only one trace of the graph. If active is selected, the marker is applied to the current active trace of the graph.


====Octave====
====1/n Octave data marker====


*  
*  
[[Image:Reports_Tools_Ribbons_463.png|framed|none]]
[[Image:Reports_Tools_Ribbons_463.png|framed|none]] Switch the cursor to add a 1/n octave data marker at the clicked graphs. The  1/n octave data marker can be positioned in CPB spectra and waterfall X/Y sections of the same type. It extracts the list of the band levels in db or linear units into the infotrace.
1/n Octave data marker:  Switch the cursor to add a 1/n octave data marker at the clicked graphs. The  1/n octave data marker can be positioned in CPB spectra and waterfall X/Y sections of the same type. It extracts the list of the band levels in db or linear units into the infotrace.


Displays all band values
Display all band values.


[[Image:Display_Graphs_Traces_160.png|framed|none]]
[[Image:Display_Graphs_Traces_160.png|500px|none]]


=====Octave marker properties=====
'''Octave marker properties'''


[[Image:Display_Graphs_Traces_161.png|framed|none]]
[[Image:Display_Graphs_Traces_161.png|250px|none]]


* Apply to
* Apply to
Line 260: Line 243:


*  
*  
[[Image:Reports_Tools_Ribbons_464.png|framed|none]]
[[Image:Reports_Tools_Ribbons_464.png|framed|none]] Switch the cursor to deposit a set of harmonics in the click location. The harmonic marker can be positioned everywhere in a spectra and waterfall X/Y sections.
Kinematic marker:  Switch the cursor to deposit a set of harmonics in the click location. The harmonic marker can be positioned everywhere in a spectra and waterfall X/Y sections.


The Kinematic marker helps identifying the frequencies (or orders) which match the various rotating speed in machineries. These frequencies are linked with a fundamental one (usually the main shaft rotating frequency) by fixed ratio. These ratios depend on the machinery kinematics.
The Kinematic marker helps identifying the frequencies (or orders) which match the various rotating speed in machineries. These frequencies are linked with a fundamental one (usually the main shaft rotating frequency) by fixed ratio. These ratios depend on the machinery kinematics.
Line 269: Line 251:
To add a kinematic marker to a window, select Kinematic from the ''Display/graph/Markers'' left button.
To add a kinematic marker to a window, select Kinematic from the ''Display/graph/Markers'' left button.


[[Image:Display_Graphs_Traces_162.png|framed|none]]
[[Image:Display_Graphs_Traces_162.png|600px|none]]


Then it becomes possible to select one marker from the list. Click ''Select Kinematic Marker ''button to open the selection dialog. Select one line from the table of the current tab and close the dialog box. The corresponding marker will be applied double clinking on a spectral graph.
Then it becomes possible to select one marker from the list. Click ''Select Kinematic Marker ''button to open the selection dialog. Select one line from the table of the current tab and close the dialog box. The corresponding marker will be applied double clinking on a spectral graph.


[[Image:Display_Graphs_Traces_163.png|framed|none]]
[[Image:Display_Graphs_Traces_163.png|600px|none]]


This type of marker may be manipulated from any of the sub-marker lines.
This type of marker may be manipulated from any of the sub-marker lines.


=====Kinematic marker properties=====
'''Kinematic marker properties'''
In the kinematic marker properties (Right click on it or through marker manager) the fundamental frequency may be adjusted in Frequency unit or RPM.
In the kinematic marker properties (Right click on it or through marker manager) the fundamental frequency may be adjusted in Frequency unit or RPM.


[[Image:Display_Graphs_Traces_164.png|framed|none]]
[[Image:Display_Graphs_Traces_164.png|400px|none]]


=====Kinematic marker Description=====
'''Kinematic marker Description''
The Kinematic descriptions for these markers are taken from ''.csv'' (or Excel™) files.
The Kinematic descriptions for these markers are taken from ''.csv'' (or Excel™) files.


[[Image:Display_Graphs_Traces_165.png|framed|none]]
[[Image:Display_Graphs_Traces_165.png|700px|none]]


The files may be modified to adjust the kinematics ratio. The files content are read every time the select kinematic marker is opened. No need to exit the NVGate software for update.
The files may be modified to adjust the kinematics ratio. The files content are read every time the select kinematic marker is opened. No need to exit the NVGate software for update.
Line 293: Line 275:
The kinematic marker operations are similar to the harmonics one.
The kinematic marker operations are similar to the harmonics one.


====Periodic====
====Periodic marker====
*  
*  
[[Image:Reports_Tools_Ribbons_465.png|framed|none]]
[[Image:Reports_Tools_Ribbons_465.png|40px]] Switch the cursor to add a periodic marks at the clicked location. The period marker can be positioned trigger blocks. Operates like an harmonic marker but in the time domain.
Period marker:  Switch the cursor to add a periodic marks at the clicked location. The period marker can be positioned trigger blocks. Operates like an harmonic marker but in the time domain.
Computes and displays periodic values for the selected trace(s).The periodic allows identifying the periodicity and frequency of repeated phenomena identified into time series graphs
Computes and displays periodic values for the selected trace(s).The periodic allows identifying the periodicity and frequency of repeated phenomena identified into time series graphs


[[Image:Display_Graphs_Traces_166.png|framed|none]]
[[Image:Display_Graphs_Traces_166.png|500px|none]]


=====Periodic marker properties=====
'''Periodic marker properties'''


[[Image:Display_Graphs_Traces_167.png|framed|none]]
[[Image:Display_Graphs_Traces_167.png|450px|none]]


* Period visibility: checklist. Only checked periods will be displayed.
* Period visibility: checklist. Only checked periods will be displayed.


* Apply to
* Apply to
* All: the marker is associated with all curves of the graph. All Y values will be computed and displayed in the free marker tab.
** All: the marker is associated with all curves of the graph. All Y values will be computed and displayed in the free marker tab.
* Associated to: the marker is associated with only one trace of the graph. If active is selected, the marker is applied to the current active trace of the graph.
** Associated to: the marker is associated with only one trace of the graph. If active is selected, the marker is applied to the current active trace of the graph.


====Recorder Marker====
====Record Marker====
*  
*  
[[Image:Reports_Tools_Ribbons_466.png|framed|none]]
[[Image:Reports_Tools_Ribbons_466.png|40px]]
(tab Measurement/ control / mark
Record marker (CTRL<nowiki>+</nowiki>M)
Record marker (CTRL<nowiki>+</nowiki>M)
Using this shortcut while the analyzer is recording, add record marker to the signal. If there is a recording window, the maker is displayed. During the recording, a comment can be added to the record marker, via the properties dialog box.
Using this shortcut while the analyzer is recording, add record marker to the signal. If there is a recording window, the maker is displayed. During the recording, a comment can be added to the record marker, via the properties dialog box.


The record marker is available from the ''Measurement\Control'' group. ''See Measurement tab§ in this document.''
The record marker is available from the ''Analysis\Record'' group. ''See [[NVGate_Ribbons:_Analysis_Tab|Analysis tab]].''


====Copy marker table====
===Copy marker table===
Available in Infotrace area. Used to copy marker data to the clipboard. The data is formatted to be pasted easily in Word<sup>®</sup> or Excel<sup>®</sup>.
Available in Infotrace area. Used to copy marker data to the clipboard. The data is formatted to be pasted easily in Word<sup>®</sup> or Excel<sup>®</sup>.


Line 337: Line 317:
[[Image:Display_Graphs_Traces_168.png|framed|none]]
[[Image:Display_Graphs_Traces_168.png|framed|none]]


====Marker table in reports====
===Marker table in reports===
The marker table can be droped in the report template. See Vol. 3 report Tools and ribbons for details.
The marker table can be droped in the report template. See [[NVGate_Report|NVGate Report]] for details.


[[category:Display_Graphs_Traces]]


=====Marker manager=====
===Marker manager===
Gives the list of all the markers in the window, except record markers. In this dialog box, any window marker can be removed or modified.
Gives the list of all the markers in the window, except record markers. In this dialog box, any window marker can be removed or modified.


Line 353: Line 332:
* '''Remove:''' Removes all checked markers from the window
* '''Remove:''' Removes all checked markers from the window
* '''Properties:''' Displays the properties dialog of the active marker of the list.
* '''Properties:''' Displays the properties dialog of the active marker of the list.
====Other function====
The rest of the group is dedicated to the marker adjustments:
*
[[Image:Reports_Tools_Ribbons_467.png|framed|none]]
Marker mode:  Switch between the marker mode (the cursor controls the marker) and the last used cursor mode. ''See this chapter (6) - §Tabs/ Measurement tab/graph group for details''
*
[[Image:Reports_Tools_Ribbons_468.png|framed|none]]
Move marker:  Moves the selected marker of the active window by one step of spectra resolution to the left or right
*
[[Image:Reports_Tools_Ribbons_469.png|framed|none]]
Move marker by 1/32<sup>nd</sup> of step:  Moves the selected marker of the active window by a 1/32<sup>nd</sup> of spectra resolution to the left or right. Allowed only if the marker is located in the vicinity (<nowiki>+</nowiki>/- 1 step) of a peak and the X& Y interpolation are enabled

Latest revision as of 17:15, 7 January 2022

Reports Tools Ribbons 26.png

NVGate features a complete set of real-time markers that help identifying typical signature and points of exception in both time and spectral graphs.

Marker description

The marker group allows selecting and positioning the chosen marker. The markers allow quantifying measurement behaviors such as the band power between 2 frequencies, track signal harmonics or tracking the max amplitude of a signal…

Display Graphs Traces 136.png

There is also a copy function using the right click from the Infotrace that allows to paste the whole marker table to Word® or Excel®.

Display Graphs Traces 137.png

Free marker

Reports Tools Ribbons 457.png

Switch the cursor to deposit a free marker in the click location. The free marker can be positioned everywhere to add a legend in a spectra, profile, 1/n octave and waterfall section.

When available, a free marker can be placed and moved within a graph to track specific values. A label can be associated with each free marker.

Right clicking on a free maker displays menu including "Properties", which opens edit free maker dialog box.

Display Graphs Traces 03.png
  • Label: The label associated with the marker. The user can enter directly a name or pick ’display current position’ to display automatically the coordinates of the selected point.
  • Position: The X position of the current marker. The position value can be fixed by entering the new value in this box.

  • Interpolation: This setting selects the interpolation of values displayed in the marker table.
  • None: no interpolation applied.
  • X: x interpolation is active.
  • X & Y: x and y interpolations are active.
Display Graphs Traces 138.png

When the interpolation function is active, the interpolated value is preceded by a "i".

Note: the interpolated values of free markers will be available only if the free marker is placed on a peak. The peak detection criteria are the same as the peak marker adjusted in the User preferences.

  • Apply to
  • All: the marker is associated with all curves of the graph. All Y values will be computed and displayed in the free marker tab.
  • Associated to: the marker is associated with only one trace of the graph. If active is selected, the marker is applied to the current active trace of the graph.

Harmonic marker

Reports Tools Ribbons 458.png

Switch the cursor to deposit a set of harmonics in the click location. The harmonic marker can be positioned everywhere in a spectra and waterfall X/Y sections.

Computes and displays harmonic values for the selected trace(s).

Display Graphs Traces 139.png

Harmonic marker properties

Display Graphs Traces 140.png
  • Harmonic visibility: Harmonics checklist. Only checked harmonics will be displayed.
  • Interpolation
  • None: no interpolation applied.
  • X: x interpolation is active.
  • X&Y: x and y interpolations are active.
Display Graphs Traces 141.png

When the interpolation function is active, the interpolated value is preceded by a "i".

Note: the interpolated values of harmonic markers will be available only if the harmonic marker is placed on a peak.

  • Apply to
    • All: the marker is associated with all curves of the graph. All Y values will be computed and displayed in the free marker tab.
    • Associated to: the marker is associated with only one trace of the graph. If active is selected, the marker is applied to the current active trace of the graph.

Peak marker

Reports Tools Ribbons 459.png

Switch the cursor to add a set of peak detection markers in the clicked graph. The peak marker detects automatically the peaks in the spectra and waterfall X/Y sections.

Computes and displays peak values for the selected trace(s).

A spectrum line is detected as a peak if two following conditions are matched:

  • The 2 adjacent spectrum line levels (N-1, N+1) are lower than the central spectrum line one’s
  • The 2 following adjacent spectrum line levels (N-2, N+2) are lower than the central spectrum level minus the peak threshold
Display Graphs Traces 142.png

Peak marker properties

  • Threshold: In the example below, the "Threshold" is 10 dB.
Display Graphs Traces 143.png
  • Ignore under: Does not display the detected peak if the peak is under this value. In the example below, the "ignore under" value is –15 dB.
Display Graphs Traces 144.png
  • Number of peak: Number of peaks to be displayed. That will first display the greatest peaks.
  • Interpolation
  • None: no interpolation applied.
  • X: x interpolation is active.
  • X & Y: x and y interpolations are active.
Display Graphs Traces 145.png

When the interpolation function is active, the interpolated value is preceded by an "i".

  • Apply to
  • All: the marker is associated with all curves of the graph. All Y values will be computed and displayed in the free marker tab.
  • Associated with: the marker is associated with only one trace of the graph. If active is selected, the marker is applied to the current active trace of the graph.
  • Damping ratio damping ratio is calculated for each detected peak. The calculation is based on the Half-power-band-width method, where DR is the damping ratio:
Damping ratio.png

The calculation of the damping factor is activated through the marker properties or preferences.


When it is activated an additional column is added in the corresponding marker table. The marker table can be saved in an MS Office document or simply copied and pasted.

Display Graphs Traces 147.png

Warning, using nonhomogeneous weighting windows (i.e.: equivalent noise bandwidths are not the same) on FRF channels leads to incorrect peak interpolation and damping results.

Max marker

Reports Tools Ribbons 460.png

Switch the cursor to add a set of maximum detection markers in the clicked graph. The max marker detects automatically the maximum in the spectra and waterfall X/Y sections.

Computes and displays max values for the selected trace(s).

A maximum is defined as a local maximum such that the variation in size of spectral density of ray, in relation to other local maximum surrounding it, is greater than a set threshold

Display Graphs Traces 148.png

Max marker properties

Display Graphs Traces 149.png
  • Hystersis
Display Graphs Traces 150.png
  • Ignore under: Does not display the detected peak if the peak is under this value. In the example below, the "ignore under" value is –15 dB.
Display Graphs Traces 151.png
  • Number of max: Number of max to be displayed. That will first display the greatest max.
  • Interpolation
  • None: no interpolation applied.
  • X: x interpolation is active.
  • X & Y: x and y interpolations are active.
Display Graphs Traces 152.png

When the interpolation function is active, the interpolated value is preceded by a "i".

  • Apply to
  • All: the marker is associated with all curves of the graph. All Y values will be computed and displayed in the free marker tab.
  • Associated to: the marker is associated with only one trace of the graph. If active is selected, the marker is applied to the current active trace of the graph.
  • Damping ratio damping ratio is calculated for each detected Maximum. The calculation is based on the Half-power-band-width method, where DR is the damping ratio:
Damping ratio.png

The calculation of the damping factor is activated through the marker properties or preferences.

When it is activated an additional column is added in the corresponding marker table. The marker table can be saved in an MS Office document or simply copied and pasted.

Display Graphs Traces 154.png

Warning, using nonhomogeneous weighting windows (i.e.: equivalent noise bandwidths are not the same) on FRF channels leads to incorrect peak interpolation and damping results.

Side band marker

Reports Tools Ribbons 461.png

Switch the cursor to add a side band marker at the clicked location. The Sideband marker can be positioned everywhere in a spectra and waterfall X/Y sections

Display values for a central frequency and side frequencies (left and right) defined by a delta value.

The management of side band markers selects the assumed porter and the first side band of modulation. The position of the cursor during the selection of the porter or the first side band is previously interpolated on the frequency axis, taking into account the frequency response of the weighting window used if the Interpolation setting allows this

Display Graphs Traces 155.png

Side band marker properties

Display Graphs Traces 156.png
  • Start: Central value.
  • Delta: Range between 2 side frequencies.
  • Number of bands: Defines the number of bands (on the left and on the right).
  • Interpolation
  • None: no interpolation applied.
  • X: x interpolation is active.
  • X & Y: x and y interpolations are active.
Display Graphs Traces 157.png

When the interpolation function is active, the interpolated value is preceded by a "i".

Note: the interpolated values of free markers will be available only if the side band marker is placed on a peak.

  • Apply to
    • All: the marker is associated with all curves of the graph. All Y values will be computed and displayed in the free marker tab.
    • Associated with: the marker is associated with only one trace of the graph. If active is selected, the marker is applied to the current active trace of the graph.

Power band marker

Reports Tools Ribbons 462.png

Switch the cursor to add a power band marker at the clicked location. The power-band marker can be positioned everywhere in a spectra and waterfall X/Y sections. It extracts the RMS power in the selected band taking in account the equivalent bandwidth of the weighting window.

Computes and displays power in signal range defined by start position and delta.

Display Graphs Traces 158.png

Power band marker properties

Display Graphs Traces 159.png
  • Start: Start value for the power band computation.
  • Delta: Bandwidth used for the computation.
  • Apply to
    • All: the marker is associated with all curves of the graph. All Y values will be computed and displayed in the free marker tab.
    • Associated with: the marker is associated to only one trace of the graph. If active is selected, the marker is applied to the current active trace of the graph.

1/n Octave data marker

Reports Tools Ribbons 463.png

Switch the cursor to add a 1/n octave data marker at the clicked graphs. The 1/n octave data marker can be positioned in CPB spectra and waterfall X/Y sections of the same type. It extracts the list of the band levels in db or linear units into the infotrace.

Display all band values.

Display Graphs Traces 160.png

Octave marker properties

Display Graphs Traces 161.png
  • Apply to
    • All: the marker is associated with all curves of the graph. All Y values will be computed and displayed in the free marker tab.
    • Associated with: the marker is associated with only one trace of the graph. If active is selected, the marker is applied to the current active trace of the graph.

Kinematic markers

Reports Tools Ribbons 464.png

Switch the cursor to deposit a set of harmonics in the click location. The harmonic marker can be positioned everywhere in a spectra and waterfall X/Y sections.

The Kinematic marker helps identifying the frequencies (or orders) which match the various rotating speed in machineries. These frequencies are linked with a fundamental one (usually the main shaft rotating frequency) by fixed ratio. These ratios depend on the machinery kinematics.

Kinematic marker fits ideally the diagnostics on bearing, gear train and belt/chain systems by helping the identification of the defects’ source.

To add a kinematic marker to a window, select Kinematic from the Display/graph/Markers left button.

Display Graphs Traces 162.png

Then it becomes possible to select one marker from the list. Click Select Kinematic Marker button to open the selection dialog. Select one line from the table of the current tab and close the dialog box. The corresponding marker will be applied double clinking on a spectral graph.

Display Graphs Traces 163.png

This type of marker may be manipulated from any of the sub-marker lines.

Kinematic marker properties In the kinematic marker properties (Right click on it or through marker manager) the fundamental frequency may be adjusted in Frequency unit or RPM.

Display Graphs Traces 164.png

'Kinematic marker Description The Kinematic descriptions for these markers are taken from .csv (or Excel™) files.

Display Graphs Traces 165.png

The files may be modified to adjust the kinematics ratio. The files content are read every time the select kinematic marker is opened. No need to exit the NVGate software for update.

Each file can contain unlimited markers and group of markers. NVGate handle simultaneously multiple kinematic descriptor files. The descriptor files have to be in the following directory (default):C:\OROS\NVGate data\Markers\Kinematic.

The kinematic marker operations are similar to the harmonics one.

Periodic marker

Reports Tools Ribbons 465.png Switch the cursor to add a periodic marks at the clicked location. The period marker can be positioned trigger blocks. Operates like an harmonic marker but in the time domain. Computes and displays periodic values for the selected trace(s).The periodic allows identifying the periodicity and frequency of repeated phenomena identified into time series graphs

Display Graphs Traces 166.png

Periodic marker properties

Display Graphs Traces 167.png
  • Period visibility: checklist. Only checked periods will be displayed.
  • Apply to
    • All: the marker is associated with all curves of the graph. All Y values will be computed and displayed in the free marker tab.
    • Associated to: the marker is associated with only one trace of the graph. If active is selected, the marker is applied to the current active trace of the graph.

Record Marker

Reports Tools Ribbons 466.png Record marker (CTRL+M) Using this shortcut while the analyzer is recording, add record marker to the signal. If there is a recording window, the maker is displayed. During the recording, a comment can be added to the record marker, via the properties dialog box.

The record marker is available from the Analysis\Record group. See Analysis tab.

Copy marker table

Available in Infotrace area. Used to copy marker data to the clipboard. The data is formatted to be pasted easily in Word® or Excel®.

Example of result with this command:

For Word®:

Free marker

Id Label Trace X Unit Y Unit

1 Marker Sig [1] 0.00141 s 5.453 V

For Excel®:

Display Graphs Traces 168.png

Marker table in reports

The marker table can be droped in the report template. See NVGate Report for details.


Marker manager

Gives the list of all the markers in the window, except record markers. In this dialog box, any window marker can be removed or modified.

Display Graphs Traces 24.png
Display Graphs Traces 25.png
  • Select All: Checks all the items of the list
  • Unselect All: Uncheck all the items of the list.
  • Remove: Removes all checked markers from the window
  • Properties: Displays the properties dialog of the active marker of the list.