Difference between revisions of "NVGate Ribbons: Acquisition"
Line 147: | Line 147: | ||
==Events group== | ==Events group== | ||
This group manages the events and corresponding triggers. It allows selecting the event type (source, setup) and associates it with the plug-in analyzers triggers. | |||
[[File:Acquisition_events_tab_2022.PNG|200px]] | [[File:Acquisition_events_tab_2022.PNG|200px]] | ||
{|border="0" cellspacing="0" cellpadding="4" width="100%" align="center" | {|border="0" cellspacing="0" cellpadding="4" width="100%" align="center" | ||
|- | |-valign="top" | ||
|[[File:Events_associate_to.PNG|30px]] | |[[File:Events_associate_to.PNG|30px]] | ||
| '''Associate to''': | | '''Associate to''': | ||
|- | |-valign="top" | ||
|[[File:Event_edge_2022.PNG|30px]] | |[[File:Event_edge_2022.PNG|30px]] | ||
| '''Edge''': | | '''Edge''': Detect when the signal from an input or a recorded track crosses a threshold. This module is used with the analog inputs (tach pulse or hammer impact). This trigger can be applied to any plug-in analyzer including Waterfall and Recorder. | ||
|- | |-valign="top" | ||
|[[File:Event_level_2022.PNG|30px]] | |[[File:Event_level_2022.PNG|30px]] | ||
| '''Level''': | | '''Level''': Detect when a signal is below or above a level This module is used with DC inputs (optional) and/or associated with the TDA or Monitor module. This event can be applied to any plug-in analyzer including Waterfall and Recorder. | ||
|- | |-valign="top" | ||
|[[File:event_periodic_2022.PNG|30px]] | |[[File:event_periodic_2022.PNG|30px]] | ||
| '''Periodic''': | | '''Periodic''': Used to trigger a plug-in by periodic step. This event can be applied to any plug-in analyzer including Waterfall and Recorder. | ||
|- | |-valign="top" | ||
|[[File:Event_RPM_2022.PNG|30px]] | |[[File:Event_RPM_2022.PNG|30px]] | ||
| '''RPM''': | | '''RPM''': Detect when a tachometer is below or above a specified angular speed. This module is associated with the Tachometer module. You need to first activate it on Tachometer plug in. This trigger can be applied to any plug-in analyzer including Waterfall and Recorder. | ||
|- | |-valign="top" | ||
|[[File:Event_delta_RPM_2022.PNG|30px]] | |[[File:Event_delta_RPM_2022.PNG|30px]] | ||
| '''Delta RPM''': | | '''Delta RPM''': Same as RPM but generates an event at each step. This module is associated with the Tachometer module. You need first to activate it on Tachometer plug in. It is used to trigger a plug-in by step. This trigger can be applied to any plug-in analyzer including Waterfall and Recorder. | ||
|- | |-valign="top" | ||
|[[File:Event_combined_2022.PNG|30px]] | |[[File:Event_combined_2022.PNG|30px]] | ||
| '''Combined''': | | '''Combined''': Generate an event which is the result of a combination of 2 events. Possible combinations are: OR, AND and AFTER. | ||
|}<br clear="all"> | |}<br clear="all"> | ||
Read [[NVGate_Event_definition|event definition]] page for details. | |||
==Filters group== | ==Filters group== |
Revision as of 09:59, 15 December 2021
Inputs group
The inputs group allows dispatching the front-end channels to the analyzer's plug-in and setting up the front-end. This group is visible in Online mode only.
Player group
This group is visible in Post-analysis mode.
Connect tracks: This button allows dispatching the signal tracks (all types) to the analysis plug-ins. | |
Record number: Define the record number (i.e. a section in the file defined during the acquisition) to be post-processed. | |
Player settings: Give a direct access to the Player settings | |
Playback mode: Allows choosing between a continuous and a step/step post-process.
| |
Step: Defines the time duration of the playback step for the "Time step" analysis mode. The player switches to "pause" every "time step" second. | |
Pause/Cont.: Enables to perform the post-analysis up to the next step. |
Transducers calibration
Enables to calibrate the sensors. This group is active only in connected mode.
See transducer and sensor page for details.
Virtual Inputs group
This group gives access to the real-time computation between channels. It is grayed out if the Virtual Inputs option is not available with the user's licenses or if no input/track is connected to this plug-in.
Dynamic: Allow modifying the virtual dynamic input properties. Available when at least one input is connected to the Virtual Input plug-in (Use the Connect Inputs button from the Inputs group for that).
Note: the Virtual Input plug-in is optional, it may not be available on the license. In that case, this button is grayed out and the Virtual Input plug-in is not present in the Connect Inputs window. | |
Parametric: Allow modifying the virtual parametric input properties. Available when at least one input is connected to the Virtual DC plug-in (Use the Connect Inputs button from the Inputs group for that).
Note: the Virtual DC plug-in is optional, it may not be available on the license. In that case, this button is grayed out and the Virtual DC plug-in is not present in the Connect Inputs window. |
See Virtual Input page for details.
Tachometers group
Manage the tachometer resources. This group allows selecting the tach type (source, setup) and associates it with the plug-in analyzers and waterfall.
Events group
This group manages the events and corresponding triggers. It allows selecting the event type (source, setup) and associates it with the plug-in analyzers triggers.
Read event definition page for details.
Filters group
Apply to: Enables to copy or move Projects / Measurements / Models from a specified source to the current Projects database. | |
High/Low pass: | |
Pass/Stop band: | |
Integrator: | |
Differentiator: |
Outputs group
Signals: Enables to copy or move Projects / Measurements / Models from a specified source to the current Projects database. | |
Sine: | |
Multi-sine: | |
Swept-sine: | |
Chirp: | |
Random noise: | |
Output settings: |