SUBJET: Using the envelope analysis for roller bearing defect detection

Objective:

Abnormal vibrations were detected on a speed reducing gear box. We proceed to the diagnostic of the machine. A default in the roller bearing is suspected. An accelerometer is positioned close to the bearing and connected to the OR3X analyzer.

Envelope 01.png

Necessary equipment:

OROS analyzer

In this example we are analysing the time signal file recorded with the analyzer. The office mode of NVGate is used.

Description:

The first step consists in the traditional FFT spectrum analysis of the signal in the complete frequency bandwith (0-20 kHz).

The zoom analysis is used in the second step. The third step describes the envelope analysis.

Finally, we will also proceed to the analysis of the demodulated signal in the fourth step


Step 1: Traditional Spectrum Analysis

In a first step, we determinate the spectrum obtained from the accelerometer signal. The signal is considered on a frequency band 0-20 kHz.

Envelope 02.png

- Spectrum Analysis

With the cursor we can detect two resonance domains. The first resonance is detected around 4.3 kHz and the second one around 13.3 kHz.


Step 2: Zoom Analysis

The traditional approach is to use a zoom analysis around 4.3 and 13.3 kHz in our case. In the NVGate software define the settings of the FFT Zoom by:

  • setting a zoom factor of 16.
  • defining the center frequency of the zoom at 4.3 kHz in a first time. We can also use the drag and drop action to place the center frequency in the averaged spectrum window.
Envelope 03.png

Figure 2 - Zoom Analysis Settings

Now the Zoomed averaged spectrum window can be displayed (Figure 3).

Envelope 04.png

Figure 3- Zoom Analysis

The zoomed spectrum helps us to have a better resolution around the carrier frequency at which the signal is demodulated. For doing this kind of analysis we can use the side band markers. Actually a typical signal spectrum can be noticed as it usually has a central frequency line with lower amplitude side lines, as shown on the figure below:

Envelope 05.gif

Figure 4- Envelope Analysis

If we see such a spectrum shape then it means we can start the envelope analysis.

In the NVGate software, we use the side band markers in the Zoomed averaged spectrum window to identify the modulation frequency (Figure 5).

Envelope 06.png

- Side band markers in the Zoomed averaged spectrum window around 13.3 kHz

We can suspect a modulation frequency of 148.4 Hz which exactly corresponds to the value of the inner bearing race defect frequency provided by the manufacturer of the ball bearing.

From the shape of this spectrum we can also see there is a modulation phenomenon. This is why we are going to proceed to the envelop analysis to check the demodulated signal and its spectrum.


Step 3: Envelope Analysis

The envelope mode is activated by choosing a zoom factor (already done in our example) and checking the box "Envelope" (Figure 6).

The Envelop trigger and the Envelope spectrum windows can now be displayed (number 4 of the Figure 6).

Envelope 07.png

Figure 6- Envelope and Zoom Analysis at 13.3 kHz

Five shocks per revolution are identified in the Envelope trigger window obtained after the signal demodulation (number 4 of the Figure 6).

We are using the Harmonic markers in the Envelope spectrum window to detect the modulation frequency that is significant of the defect in the gear box. In our case we confirm that the frequency at 148.4 Hz is the modulation frequency (Figure 7).

Envelope 08.png

Step 3: Analysis of the demodulated signal

From the envelope signal window we can also detect the two characteristic frequencies previously found (Figure 8):

Envelope 09.png

Figure 8 – Zoom display on the envelope trigger window