Difference between revisions of "NVGate Sequence"

From OROS Wiki
Jump to navigation Jump to search
(Created page with " ====Sequences==== The sequencer is used to import/export/load/view an Excel® file that contains a series of steps. These steps are executed one by one. The sequencer is gene...")
(No difference)

Revision as of 13:04, 19 April 2020

Sequences

The sequencer is used to import/export/load/view an Excel® file that contains a series of steps. These steps are executed one by one. The sequencer is generally used to operate the Roving hammer impact for modal acquisition, for example.

Reports Tools Ribbons 123.png
Manage
Reports Tools Ribbons 124.png

Opens the Sequence manager and displays the sequences list.

Reports Tools Ribbons 125.png
  • Import: Imports a sequence from an Excel® file, to create a sequence in NVGate format. Sequences in NVGate format are stored in the "Sequence" directory.

Names of sequences in NVGate format are displayed by the sequence manager.
See Source format for more information about sequences in Excel®.

  • Export: Exports selected sequence (in NVGate format) to Excel®.
  • Load: Loads selected sequence. Only the loaded sequence can be executed or opened in the sequence viewer to perform a modal analysis.
  • View: Opens the selected sequence in the Sequence viewer. Only the loaded sequence can be opened in the viewer.

A Sequence is a set of acquisitions. Each acquisition is a set of setting modifications, and it is associated to a measurement. When a measurement is performed, the acquisition associated with it, is called the current acquisition and is designated by the execution pointer (yellow arrow to the left of the sequence tree). At the end of each measurement, next acquisition becomes current and is executed to prepare the next measurement. When an acquisition is executed, all settings assigned to it are applied.

  • Run/Pause
Reports Tools Ribbons 126.jpg
When the sequence is not running, it is launched from the current acquisition. The current acquisition is executed to prepare the measurement.

Note: The Pause button operates at the inverse of the enable button in the sequence group ribbon.

  • Reset
Reports Tools Ribbons 127.jpg
Sets the execution pointer (which designates the current acquisition) to the first acquisition of the sequence.

Note: the reset button operates like the reset button in the sequence group ribbon

  • Back to previous
Reports Tools Ribbons 128.jpg
The acquisition preceding the current acquisition becomes current and is executed.

Disabled if sequence is running.

  • Run next
Reports Tools Ribbons 129.jpg
The acquisition following the current acquisition becomes current and is executed.

Disabled if the sequence is running.

Note: Next and previous button operates like the sequence browser arrows in the sequence group ribbon

  • Jump to: Accessible by right-clicking on the acquisition. This acquisition becomes current.
  • Delete: Deletes the selected acquisition.
  • Properties: Edits sequence properties.
Reports Tools Ribbons 130.png

When "Run after setup" is checked, a new measurement is launched automatically after the current acquisition is executed.

Source format

"Roving hammer test" sequence in Excel®.

Reports Tools Ribbons 131.png

"Roving hammer test" sequence in NVGate

Reports Tools Ribbons 132.gif

The first Excel® cell is dedicated to sequence name.

The first column contains the name of acquisitions.

The second column contains, for each acquisition, the key words which identify the NVGate configuration sub-modules.

Reports Tools Ribbons 02.png

Second line is composed of the keywords, which identify the NVGate configuration’s settings.

They can be found in the ASB.

Reports Tools Ribbons 133.png

The column called ’Remote Node Label’ is the field displayed by the remote controller.

Menu ’Impact’ of the remote controller

These key words in the excel file, should be also defined in the Sequence.ini file which contains alias definitions. An IDNumber is associated to each setting. It can be retrieved from the ASB in NVGate by using shift + right click on the corresponding setting. Settings aliases could be modified by users.

Part of Sequence.ini file

Each couple (sub-module key word, setting keyword) designates a specific setting in the NVGate configuration. The value to assign to this setting is defined in the corresponding cell.

The semicolon character marks the rest of a line as a comment.

Enable
Reports Tools Ribbons 134.png

Enable/disable the sequence execution. When the loaded sequence is enabled, the steps are executed each time the analyzer finish an acquisition/analysis (i.e: the general status switch to STOP)

Reset
Reports Tools Ribbons 135.png

Reset the sequence to the initial step, execute it and disable the sequence

Browse
Reports Tools Ribbons 136.png

Move to the next or previous step in the sequence. Disabled when the sequence is enabled.

Active sequence name
Reports Tools Ribbons 137.png

Shows the loaded sequence name.

Current step

Displays the name of the current step. The current step is the one which has been executed at the last stop.