9,087
edits
(24 intermediate revisions by 2 users not shown) | |||
Line 1: | Line 1: | ||
[[category:WikiOros]] | |||
[[category:NVGate2023]] | [[category:NVGate2023]] | ||
OROS strives to be closer to its users, carefully listening to needs and requests. For that reason, OROS regularly releases new versions. Customers under contract automatically benefit from each release. | OROS strives to be closer to its users, carefully listening to needs and requests. For that reason, OROS regularly releases new versions. Customers under contract automatically benefit from each release. | ||
Line 12: | Line 10: | ||
The [[NVGate V16: Install Process|NVGate® 2023 (V16)]], which is compatible with our latest hardware [[OR3X Hardware Instruments|O4]] and new solution [[Monitoring Solution|Monitoring]], became available in February 2023. | The [[NVGate V16: Install Process|NVGate® 2023 (V16)]], which is compatible with our latest hardware [[OR3X Hardware Instruments|O4]] and new solution [[Monitoring Solution|Monitoring]], became available in February 2023. | ||
The NVGate® 2023.1 major version became available in November 2023. This release of the OROS 3-Series analyzer’s software platform brings additional functionalities and significant performance improvements. Below is a summary of the main enhancements of your NVGate experience:<br> | The NVGate® 2023.1 (V16.10) major version became available in November 2023. This release of the OROS 3-Series analyzer’s software platform brings additional functionalities and significant performance improvements. Below is a summary of the main enhancements of your NVGate experience:<br> | ||
Line 38: | Line 36: | ||
To download and install NVGate 2023.1, [[NVGate_2023:_Install_Process|check this page]]. | To download and install NVGate 2023.1, [[NVGate_2023:_Install_Process|check this page]]. | ||
<br><br> | <br><br> | ||
Compatibility: NVGate 2023 is compatible with | [[NVGate_2023:_Release_note#Compatibility|Compatibility*]]: NVGate 2023 is compatible with the following OROS instruments: O4 - OR34 - OR10 - OR35 TW - OR36 TW - OR38 TW. Depending on the hardware options and version, some instrument features may or may not be available. | ||
Line 54: | Line 52: | ||
With '''NVGate ADVISOR''', the metrology watchdog developed with OROS know-how accumulated over 40 years, you will always be accompanied by a noise and vibration expert. | With '''NVGate ADVISOR''', the metrology watchdog developed with OROS know-how accumulated over 40 years, you will always be accompanied by a noise and vibration expert. | ||
You are doing '''impact testing'''? Check out this step-by-step guide!<br> | |||
<youtube>https://youtu.be/qIoZNEcy_K4</youtube> | <youtube>https://youtu.be/qIoZNEcy_K4</youtube> | ||
You are doing '''rotating machine analysis'''? Check out this video!<br> | |||
<youtube>https://youtu.be/mK5_RFjIZhU</youtube> | |||
Line 64: | Line 70: | ||
When one or more issues are detected, the user will be notified immediately by the “Advisor” icon in the “Home” tab and “Analysis” tab, <br> | When one or more issues are detected, the user will be notified immediately by the “Advisor” icon in the “Home” tab and “Analysis” tab, <br> | ||
[[File:Advisor_1_1.png | [[File:Advisor_1_1.png]] | ||
or by the icon at the lower right corner of NVGate. <br> | or by the icon at the lower right corner of NVGate. <br> | ||
Line 79: | Line 85: | ||
[[File:advisor_blue.png|40px]] '''Suggestion ''' (blue): It might not be a mistake, but probably a negligence. <br> | [[File:advisor_blue.png|40px]] '''Suggestion ''' (blue): It might not be a mistake, but probably a negligence. <br> | ||
=== Explanation and suggestion === | === Explanation and suggestion === | ||
Click on the Advisor icon, and the Advisor window will be opened. The bar in the beginning means that this Advice is new and unread. In each Advice, the explanation of the detected issue is given, and corresponding solution or suggestion is proposed to assist the user to set up properly and obtain correct measurements. Based on the information, the user can decide to fix the issue or ignore it. <br> | Click on the Advisor icon, and the Advisor window will be opened. The bar in the beginning means that this Advice is new and unread. In each Advice, the explanation of the detected issue is given, and corresponding solution or suggestion is proposed to assist the user to set up properly and obtain correct measurements. Based on the information, the user can decide to fix the issue or ignore it. <br> | ||
[[File:advisor_window.png | [[File:advisor_window.png]] | ||
=== Actions === | === Actions === | ||
Line 101: | Line 105: | ||
Advisor works in both online and post analysis modes, helping user to properly set up NVGate efficiently. The majority of current Advices are for the application of impact testing and rotating machine analysis, and more Advices covering a wider range of applications will be available in the future NVGate versions. <br> | Advisor works in both online and post analysis modes, helping user to properly set up NVGate efficiently. The majority of current Advices are for the application of impact testing and rotating machine analysis, and more Advices covering a wider range of applications will be available in the future NVGate versions. <br> | ||
== [[File:modbus_resize.png|70px]] Modbus TCP/IP client add-on compatibility == | == [[File:modbus_resize.png|70px]] Modbus TCP/IP client add-on compatibility == | ||
The new '''Modbus TCP/IP''' client add-on is available now. It reads entries from Modbus server and injects the data to NVGate in '''real-time'''. <br> | The new '''[[Modbus_TCP/IP_to_NVGate|Modbus TCP/IP]]''' client add-on is available now. It reads entries from Modbus server and injects the data to NVGate in '''real-time'''. <br> | ||
[[File:modbus-drawing.png| | [[File:modbus-drawing.png|800px]] | ||
The add-on reads from Modbus server the entries which are synchronized with '''dynamic / parametric / Ext. sync.''' channels acquired from OR3X analyzer, and reinjects the entries to NVGate in real-time using simulated DC channels. These values are then managed as DC data in NVGate. The entries can be saved as '''properties''' of projects / measurements automatically. They can also be used to '''trigger''' measurements (recorder, SOA, waterfall …). | The add-on reads from Modbus server the entries which are synchronized with '''dynamic / parametric / Ext. sync.''' channels acquired from OR3X or O4 analyzer, and reinjects the entries to NVGate in real-time using simulated DC channels. These values are then managed as DC data in NVGate. The entries can be saved as '''properties''' of projects / measurements automatically. They can also be used to '''trigger''' measurements (recorder, SOA, waterfall …). | ||
Line 119: | Line 122: | ||
The most common '''rotating speed sensors''' are now available in the transducer database. User simply selects the sensor from the transducer list, and the tachometer settings are ready. <br> | The most common '''rotating speed sensors''' are now available in the transducer database. User simply selects the sensor from the transducer list, and the tachometer settings are ready. <br> | ||
[[File:tacho_connection.png | [[File:tacho_connection.png]] | ||
The transducers in the list can be '''customized''', and '''new transducers''' can be added by editing the file “Tachometers.tdb”, which can be found in the installation directory of NVGate. | The transducers in the list can be '''customized''', and '''new transducers''' can be added by editing the file “Tachometers.tdb”, which can be found in the installation directory of NVGate. | ||
== New default settings == | == New default settings == | ||
Line 160: | Line 162: | ||
== Bug fixing == | == Bug fixing == | ||
'''In NVG2023.1''': | |||
* 14729: CANBus J1939 compatibility | * 14729: CANBus J1939 compatibility | ||
* 15258: CANBus: Add CAN 2.0B | * 15258: CANBus: Add CAN 2.0B | ||
* 15376: Tortional velocity measured from tacho at slow speed becomes 0 | * 15376: Tortional velocity measured from tacho at slow speed becomes 0 | ||
* 15372: Phase difference between online results and post-analysis results | * 15372: Phase difference between online results and post-analysis results | ||
* 15367 :Integrator filter at very low frequency phase can be difference in PA and acquisition mode due to HP filter | |||
* 15329: Integrator filter on accelerometer in teamwork mode, value in post-analysis is not velocity | * 15329: Integrator filter on accelerometer in teamwork mode, value in post-analysis is not velocity | ||
* 15314: In Japanese OS, “Next” button is not correctly loaded in display window | * 15314: In Japanese OS, “Next” button is not correctly loaded in display window | ||
Line 177: | Line 181: | ||
* 14913: 2 "Channel connection properties" windows at once | * 14913: 2 "Channel connection properties" windows at once | ||
* 14025: Press cancel when asked to save the measurement, the sequence jumps ahead | * 14025: Press cancel when asked to save the measurement, the sequence jumps ahead | ||
'''In NVG2023 (V16)''': | |||
* 15137: Problem when save waterfall slice with holes in reference values | |||
* 15091: Add setting “record on analyzer or on PC” in the ribbon menu | |||
* 15127: Dongle value shows “0” in NVGate connection window | |||
* 15107: Several NVDrive commands are not UTF-8 compatible | |||
* 15077: NVDrive command GetActiveTrace always returns -1 | |||
* 15074: Unit changes when saving FFT profile order | |||
* 15073: In Japanese OS, the bottom buttons in Environment are hidden | |||
* 15072: Problems with section manager of 1/N octave | |||
* 14955: Signal corrupts with double sampling frequency | |||
* 14826: NVDrive command GSRL_GetInputName does not return the correct value | |||
* 14770: PA on a part of the signal: OCT results are not consistent at high frequencies | |||
* 14761: Default transducer: wrong applied sensitivity in PA | |||
* 14757: Wrong SOA tach when draw a bode diagram | |||
* 14748: Select inputs - the filter function for transducers improved | |||
* 14704: Edit measurement does not work when load a measurement in "reader mode" | |||
* 14520: Sound volume problem | |||
===Compatibility=== | |||
NVGate 2023 is compatible with the following OROS instruments: O4 - OR34 - OR10 - OR35 TW - OR36 TW - OR38 TW. Depending on the hardware options and version, some instrument features may or may not be available. | |||
Note 1 : OR35 V1, OR36 V2, and OR38V2 (end of maintenance in 02/2021) have not been tested with this version. It could work, but will not be supported by OROS in case of issues. | |||
Note 2 : OR34 is now being replaced by O4. NVGate 2023 will be the last version supported and available for OR34. |