==Introduction==
A rotor is a shaft rotating around its axis during service. In general such a rotor consists of a shaft with one or more discs fitted to the axle. Such discs can be fly wheels, grinding wheels, turbine wheels, etc. The shaft is usually running in bearings allowing the rotation of the body. Depending on their rotational speed, two basic categories can be defined to classify rotors: <u>rotors with rigid shaft</u>, and <u>rotors with flexible shaft</u>. <br>
A rotor is a shaft rotating around its axis during service. In general, such a rotor consists of a shaft with one or more discs fitted to the axle. Such discs can be fly wheels, grinding wheels, turbine wheels, etc. The shaft is usually running in bearings allowing the rotation of the body. Depending on their rotational speed, two basic categories can be defined to classify rotors: <u>rotors with rigid shaft</u>, and <u>rotors with flexible shaft</u>. <br>
<br>
<br>
If the operating speed remains below half of the first critical bending speed, the shaft does not deflect : it may be considered as a rotor with a rigid shaft. At such operational speeds and due to the non circular cross section of the rotor, the axis of rotation (Z) and the inertial axis (&Delta;) does not coincide (e.g. the mass is not evenly dispatched in a section of the shaft). This may results in a tumbling movement of the structure, which amplitude depends on the bearing clearance and stiffness. In any case, the bearings are subjected to unnecessary or even non allowed loads.  
If the operating speed remains below half of the first critical bending speed, the shaft does not deflect : it may be considered as a rotor with a rigid shaft. At such operational speeds and due to the non circular cross section of the rotor, the axis of rotation (Z) and the inertial axis (&Delta;) does not coincide (e.g. the mass is not evenly dispatched in a section of the shaft). This may results in a tumbling movement of the structure, this amplitude depends on the bearing clearance and stiffness. In any case, the bearings are subjected to unnecessary or even not allowed loads.  


[[Image:Unbalanced_shaft_schem.png|framed|center|''Unbalance : inertial axis does not coincide with rotational axis.<br> The unevenly mass distribution is represented by "m"'']]<br>
[[Image:Unbalanced_shaft_schem.png|framed|center|''Unbalance : Inertial axis does not coincide with rotational axis.<br> The unevenly mass distribution is represented by "m"'']]<br>


At higher speeds the shaft will deflect, due to is own stiffness. In that case, it might be considered as a rotor with flexible shaft.  Depending on the position of the discs on the shaft they can even be inclined and thus create an oil whirl. In that case, the Multiplane Balancing solution must be used.<br>
At higher speeds the shaft will deflect, due to is own stiffness. In that case, it might be considered as a rotor with flexible shaft.  Depending on the position of the discs on the shaft they can even be inclined and thus create an oil whirl. In that case, the Multiplane Balancing solution must be used.<br>
Line 80: Line 81:
'''Accelerometer'''
'''Accelerometer'''


The measurement direction of the accelerometer must be referred to the tach sensor position. This can be done by the "Angular correction" in the analyzer setup. In our example in '''Sketch 1,''' the '''angular correction''' </font>is '''90°''' and the <font color="#339966">'''offset''' </font>is -'''15 °'''.
The measurement direction of the accelerometer must be referred to the tach sensor position. This can be done by the "Angular correction" in the analyzer setup. In our example, in '''Sketch 1,''' the '''angular correction''' </font>is '''90°''' and the <font color="#339966">'''offset''' </font>is -'''15 °'''.


'''Tip'''
'''Tip'''
Line 120: Line 121:


===Physical Background===
===Physical Background===
The <u>initial run</u> analyses the behavior of the rotor due to its initial unbalance.
The <u>initial run</u> analyzes the behavior of the rotor due to its initial unbalance.


During the <u>test run</u>, the applied test masses modify the position of the unbalance. This yields the sensitivity of the rotor. Thus with the knowledge of the reaction of the rotor to added masses, suitable masses can be calculated to compensate the initial unbalance.
During the <u>test run</u>, the applied test masses modify the position of the unbalance. This yields the sensitivity of the rotor. Thus with the knowledge of the reaction of the rotor to added masses, suitable masses can be calculated to compensate the initial unbalance.


For <u>balancing in one plane</u>, just one test mass and one test run is necessary. It is important that the angular position of the initial unbalance is changed   significantly by the test mass. Take this into account, when choosing test weight and position.
For <u>balancing in one plane</u>, just one test mass and one test run is necessary. It is important that the angular position of the initial unbalance is changed significantly by the test mass. Take this into account when choosing test weight and position.


When <u>balancing in two planes</u>, two test runs are necessary. For each run only one test mass is necessary positioned in one of both planes respectively. Again in both test runs the position of the unbalance must be changed by the test masses.
When <u>balancing in two planes</u>, two test runs are necessary. For each run only one test mass is necessary to be positioned in one of both planes respectively. Again, in both test runs the position of the unbalance must be changed by the test masses.


'''Assumptions'''
'''Assumptions'''
Line 134: Line 135:
'''Example'''
'''Example'''


Imagine a rotating machine to be balanced when standing untightened on the floor. After the test mass is mounted the increased unbalance       causes the machine to move. Holding or fixing the machine during the test run will cause wrong balancing results. To overcome this chose lower test mass or position to reduce the unbalance. If this doesn<nowiki>'</nowiki>t work you could fix the machine during the <u>complete</u> balancing procedure. After this basic balancing execute a second complete balancing procedure with the machine unfixed (in normal operating conditions).
Imagine a rotating machine to be balanced when standing untightened on the floor. After the test mass is mounted the increased unbalance causes the machine to move. Holding or fixing the machine during the test run will cause wrong balancing results. To overcome this you must choose a lower test mass or position to reduce the unbalance. If this doesn<nowiki>'</nowiki>t work you could fix the machine during the <u>complete</u> balancing procedure. After this basic balancing, execute a second complete balancing procedure with the machine unfixed (in normal operating conditions).


'''General advice'''
'''General advice'''
Line 193: Line 194:


{|border="2" cellspacing="0" cellpadding="4" width="100%"
{|border="2" cellspacing="0" cellpadding="4" width="100%"
|'''(1) Project Base : '''List of the project in the current Project Base<br>'''(2) Projects Base Path :'''Change the Project Base<br>'''(3)Project Browse : ''' Add project in the current Base.
|'''(1) Project Base : '''List of the project in the current Project Base<br>'''(2) Projects Base Path :'''Change the Project Base<br>'''(3) Project Browse : ''' Add project in the current Base.
|'''(4) New Project :''' Create a new project<br>'''(5) Exit :''' Exit the balancing program
|'''(4) New Project :''' Create a new project<br>'''(5) Exit :''' Exit the balancing program


|}
|}


[[Image:Bal_Proj_Man.png|framed|none]]
[[Image:Bal_Proj_Manager.png|framed|none]]


=====Load an existing Project======
=====Load an existing Project=====


To load an existing project, select the project in the '''(1) Project Base''' and click OK.


----
You can import a project form another database by clicking on '''(3) Browse Project'''.


=====Create a new Project=====
=====Create a new Project=====
'''Step 1'''
To create a new project, click on '''(4) New Project''' and enter the name of the project in the appearing ribbon at the bottom of the window :
 
[[Image:New_Proj.png|framed|none]]<br>
'''(1) '''</font>Click to open the explorer,''' (2)''' </font>In the Explorer, '''(3)''' </font>click to open a new sub directory
 
'''(4)''' </font>Rename the new sub directory to "Machine" and double click to change into the new subdirectory
 
[[Image:Balancing_15.png|framed|none]]
 
''Project generation''
 
'''Step 2:'''
 
'''(1)''' </font>Sub directory Machine '''(2)''' </font>Enter project name Engine A '''(3)''' </font>Click to save the new project
 
[[Image:Balancing_16.png|framed|none]]
 
''Project generation''


'''Step 3: Load the new Project'''
The new project will then appear in the Project Base, select it and click OK :


''' (1)'''Change the directory to "Machine" sub directory
[[Image:New_Proj2.png|framed|none]]<br>
 
'''(2)''' Project List Engine A
 
'''(3)''' Selection Engine A
 
'''(4)''' Click to start the program with the new Project Engine A
 
[[Image:Balancing_17.png|framed|none]]
 
''Project generation''


====Select the configuration of the machine====
====Select the configuration of the machine====
Line 260: Line 237:
To choose your transducer from the transducer data base, click on '''Transducer'''.
To choose your transducer from the transducer data base, click on '''Transducer'''.


'''Notice: '''Your tach signal must have one pulse per revolution.
====Transducer database====
 
[[Image:Balancing_22.png|framed|none]]
 
''Transducer data base''
 
For easier and faster adjustment use the transducer data base.
 
Input your transducer in the list shown by clicking the corresponding fields and adjust an input transducer label, unit and sensitivity.
 
To select a transducer click in the corresponding line, and choose the analyzer channel, where this transducer is connected to. Click '''Set.'''
 
The transducer data base can be saved and reloaded.
 
It is also possible to create several data bases for example for different users and their transducers.
 
====Setting the tachometer====
 
To set the tachometer, you need to go into the "Speed" tab :
[[Image:Bal_Tacho.png|framed|none]]
 
'''Note: '''Your tach signal must have one pulse per revolution. If you have more than one pulse, you can set the maximal speed as Real_speed*Pulse/rev.


* Set the range, coupling and slope for this tach signal.
* Set the range, coupling and slope for this tach signal.
* Choose the speed range in which you want to observe your rotor.
* Input the balancing speed.
* Input the balancing speed.
* Set the number of averages for your measurements.
* Set the number of averages for your measurements.
* An eventually needed phase correction can be introduced here. See chapter '''1 Introduction'''.
* Choose an appropriate sampling frequency.
* All adjustments can be saved and reloaded


[[Image:Balancing_21.png|framed|none]]
====Set a phase adjustment====
 
To set a phase adjustment, you can specify the position of the sensors. To enter the menu, click on "Position":
 
[[Image:Bal_Position.png|framed|none]]<br>
 
The position of each sensors and the tachometer can be set :
[[Image:Bal_Position_Menu.png|framed|none]]<br>
 
'''Note :''' The 0° position is the position of the tachometer reflector on the shaft. The angle are counted positive in the anti-rotation direction.


''Saving the channel and measuring setup''
====Saving the channel and measuring setup====


All setup settings can be saved and reloaded.
All setup settings can be saved and reloaded with "<u>S</u>ave" and "<u>L</u>oad" buttons.<br>


'''Notice:'''  '''The balancing module''' always starts with the analyzer settings that have been used last.
'''Note:'''  '''The balancing module''' always starts with the last analyzer settings used.<br>


You do not need to do all adjustments for a new project. Just load the setup of an existing project.
You do not need to do all adjustments for a new project. Just load the setup of an existing project.<br>


'''Tip:'''
'''Tip:'''<br>


If you want to make sure, you always start with the same settings, create a reference project with all settings adjusted properly. Each part of the project is saved with a specific extension.
If you want to make sure you always start with the same settings, create a reference project with all settings adjusted properly. Each part of the project is saved with a specific extension.


* Reference Project =  *.WSR
* Reference Project =  *.WSR
Line 292: Line 296:
For a new Project with these Settings: Load Reference Project.
For a new Project with these Settings: Load Reference Project.


This is now the last project that has been used
This is now the last project that has been used:


* Create New Project: It has the settings of the Reference Project.
* Create New Project: It has the settings of the Reference Project.
Line 300: Line 304:
* Click "Continue" to proceed to the next step.
* Click "Continue" to proceed to the next step.


====Transducer database====
[[Image:Balancing_22.png|framed|none]]
''Transducer data base''
For easier and faster adjustment use the transducer data base.
Input your transducer in the list shown by clicking the corresponding fields and adjust an input transducer label, unit and sensitivity.
To select a transducer click in the corresponding line, and choose the analyzer channel, where this transducer is connected to. Click '''Set.'''
The transducer data base can be saved and reloaded.
It is also possible to create several data bases for example for different users and their transducers.


----
----


====Rotor geometry and balancing quality====
====Rotor geometry and balancing quality====
<u>Example</u>


{|border="2" cellspacing="0" cellpadding="4" width="100%"
{|border="2" cellspacing="0" cellpadding="4" width="100%"
|'''(1)''' No. of mass positions Enter 12 for both planes<br>'''(2)''' Radius 100 <nowiki>[</nowiki>mm<nowiki>]</nowiki> <br>''' (3)''' Offset     15 <nowiki>[</nowiki>Deg<nowiki>]</nowiki><br>'''(4)'''  Click on Apply to display the circle<br>'''(5)'''  Unit of Unbalance <nowiki>[</nowiki>g mm<nowiki>]</nowiki> or <nowiki>[</nowiki>oz in<nowiki>]</nowiki>
|'''(1)''' No. of mass positions both planes<br>'''(2)''' Radius for both planes<nowiki>[</nowiki>mm<nowiki>]</nowiki> <br>''' (3)''' Offset of the first mass position regarding the reference at 0°  <nowiki>[</nowiki>Deg<nowiki>]</nowiki><br>'''(4)'''  Click on Apply to display the circle<br>'''(5)'''  Unit of Unbalance <nowiki>[</nowiki>g mm<nowiki>]</nowiki>, <nowiki>[</nowiki>oz in<nowiki>]</nowiki> or <nowiki>[</nowiki>g in<nowiki>]</nowiki>
|'''(6)'''  Rotor mass<br>'''(7)'''  Speed RPM<br>'''(8)'''  Quality class<br>'''(9)''' Residual unbalance <nowiki>[</nowiki>g mm<nowiki>]</nowiki><br>'''(10)'''  Residual unbalance <nowiki>[</nowiki>oz in<nowiki>]</nowiki>
|'''(6)'''  Rotor mass<br>'''(7)'''  Speed RPM<br>'''(8)'''  Quality class (def. in ISO1940/1)<br>'''(9)''' Maximal residual unbalance (according to ISO1940) <nowiki>[</nowiki>g mm<nowiki>]</nowiki><br>'''(10)'''  Residual unbalance <nowiki>[</nowiki>oz in<nowiki>]</nowiki>


|}
|}


[[Image:Balancing_23.png|framed|none]]
[[Image:Bal_Rotor_Quality.png|framed|none]]


''Rotor geometry and balancing quality''
''Rotor geometry and balancing quality''


====Measurement monitor settings====
In this window, the test runs and plane are positioned as follow :  
 
{|border="2" cellspacing="0" cellpadding="4" width="100%"
|align = "center"|
[[Image:Balancing_24.png|framed|none]]
<br>''Display settings - Diagram 1 - Plane 1''
|align = "center"|
[[Image:Balancing_25.png|framed|none]]
<br>''Display settings - Diagram 2 - Plane 2''
 
|}
 
'''Notice: The balancing module''' always starts with the monitor that has been used last.
 
All Settings can be modified:


* Set the number of graphs, the type and the order in which you want to see them.
[[Image:Bal_2_Test_Prep.png|framed|none]]<br>
Graphs with frames can be treated like windows in Windows®.


* Chose the scaling of the axis or use auto scaling (Y-axis only).
You can export and reload a configuration with the "Export" and "Load" buttons.
* Colors and graph names can be arranged.
* <u>Click "Set" to create your new monitor.</u>
* Use "Save" at the bottom to save your new monitor.
If you want to use several monitors with different layouts put existing monitors into the monitor table (double click a field in the table).
 
You can save and reload this selection of layouts.
 
Continue with "Close"


==One plane balancing==
==One plane balancing==
Line 372: Line 337:
If you use accelerometers for your measurement the signal can be integrated to show vibration velocity.
If you use accelerometers for your measurement the signal can be integrated to show vibration velocity.


'''The analyzer is now ready for measurement.'''
The '''Rotor''' window is automatically displayed. You can now prepare your test run or close this window to set it up later:
 
Your settings are shown by a red point in the polar graph.
 
There are three methods:
 
* '''Remove test masses ''' : The test mass will be removed after test for example bolts etc.
* '''Keep test masses ''' : The test mass cannot be removed after the test (for example for welding or drilling etc…)
* '''Displace two masses per plane '''for machines with slidable balancing weights.
The figure below shows an example where test mass is to be removed. The test mass of 4.2 grams is set at position 4 (105°; radius 100 mm).
 
The settings are saved automatically when closing the window. To use these settings in another project, click on export '''(1)''' </font>and save it in the sub directory of the other project. Proper settings can be loaded from another project '''(2)'''</font>.
 
[[Image:Bal_1_Test_Prep.png|framed|none]]
 
Click on OK to come back on the measurment window.<br>
 
'''The analyzer is now ready for measurement.'''<br>


To start the analyzer click '''(1)''' or <nowiki>[</nowiki>F2<nowiki>]</nowiki> and the Measurement is displayed.
To start the analyzer click '''(1)''' or <nowiki>[</nowiki>F2<nowiki>]</nowiki> and the Measurement is displayed.
Line 386: Line 368:
'''(d)''' Balancing calculation
'''(d)''' Balancing calculation


[[Image:Balancing_26.png|framed|none]]
[[Image:Bal_Wind.png|framed|none]]


* ''Measurement display - start analyzer''
* ''Measurement display - start analyzer''
====Measurement monitor settings====
[[Image:Bal_MonitorSetting.png|framed|none]]
<br>''Display settings - Diagram 2 - Plane 2''
'''Notice: The balancing module''' always starts with the monitor that has been used last.
All Settings can be modified:
* Set the number of graphs, the type and the order in which you want to see them.
Graphs with frames can be treated like windows in Windows®.
* Chose the scaling of the axis or use auto scaling (Y-axis only).
* Colors and graph names can be arranged.
* <u>Click "Set" to create your new monitor.</u>
* Use "Save" at the bottom to save your new monitor.
If you want to use several monitors with different layouts put existing monitors into the monitor table (double click a field in the table).
You can save and reload this selection of layouts.
Continue with "Close"


===Initial run===
===Initial run===
Line 397: Line 401:
The figure below shows the result of the initial run.
The figure below shows the result of the initial run.


[[Image:Balancing_27.png|framed|none]]
[[Image:Bal_1_Init.png|framed|none]]


''Initial run - start average''
''Initial run - start average''
Line 405: Line 409:
Polar graph: The blue point represents the magnitude and phase of the first order of averaged order spectrum (10 averages). Click "Initial run" '''(1)''' </font>and save the initial measurement '''(2)'''</font>.
Polar graph: The blue point represents the magnitude and phase of the first order of averaged order spectrum (10 averages). Click "Initial run" '''(1)''' </font>and save the initial measurement '''(2)'''</font>.


[[Image:Balancing_28.png|framed|none]]
[[Image:Bal_1_Stopped.png|framed|none]]


''Initial run''
''Initial run''
Line 411: Line 415:
After saving the initial run the results are displayed as shown in '''the figure below.'''
After saving the initial run the results are displayed as shown in '''the figure below.'''


[[Image:Balancing_29.png|framed|none]]
[[Image:Bal_1_Init_Result.png|framed|none]]


''Results of Initial run''
''Results of Initial run''
Line 417: Line 421:
On this figure, the blue circle, representing the allowed residual unbalance, shows directly after the initial run if the machine meets the required balancing quality or not.
On this figure, the blue circle, representing the allowed residual unbalance, shows directly after the initial run if the machine meets the required balancing quality or not.


'''Notice: '''At this point the tables only show amplitude and phase. The unbalance in <nowiki>[</nowiki>g mm<nowiki>]</nowiki> or in <nowiki>[</nowiki>oz in<nowiki>]</nowiki> can only be calculated after the rotor sensitivity is measured in the test run. Click OK to proceed to the test run.
'''Note: '''At this point the tables only show amplitude and phase. The unbalance in <nowiki>[</nowiki>g mm<nowiki>]</nowiki> or in <nowiki>[</nowiki>oz in<nowiki>]</nowiki> can only be calculated after the rotor sensitivity is measured in the test run. Click OK to proceed to the test run.


===Test run===
===Test run===
Line 423: Line 427:


* Fix a test mass to the rotor.
* Fix a test mass to the rotor.
* Mass, value and position must be set in the rotor geometry table.
* Mass, value and position must be as set in the rotor geometry table.<br>
To do this, click "Rotor" in the Measurement monitor to open the rotor geometry window'''.'''
 
Your settings are shown by a red point in the polar graph.
 
There are three methods:
 
* '''Remove test masses '''after test for example bolts etc.
* '''Keep test masses '''after the test (for example for welding or drilling etc…)
* '''Displace two masses per plane '''for machines with slidable balancing weights.
The figure below shows an example where test mass is to be removed. The test mass of 4.2 grams is set at position 4 (105°; radius 100 mm).


The settings are saved automatically when closing the window. To use these settings in another project, click on export '''(1)''' </font>and save it in the sub directory of the other project. Proper settings can be loaded from another project '''(2)'''</font>.
To see the position and mass, click "Rotor" in the Measurement monitor to open the rotor geometry window'''.'''
[[Image:Bal_1_Test_Prep.png|framed|none]]<br>


[[Image:Balancing_30.png|framed|none]]
Your settings are shown by a red point in the polar graph. If you haven't set the test mass previously, you can do it now.


''Test mass positioning for one plane''
Click on OK to go back in the Measurement window. Click "Test run" '''(1)''' </font>and save the measurement '''(2)'''</font>.
 
Click "Test run" '''(1)''' </font>and save the measurement '''(2)'''</font>.


After every test run, don<nowiki>'</nowiki>t forget to remove the test mass '''(3)'''.
After every test run, don<nowiki>'</nowiki>t forget to remove the test mass '''(3)'''.


[[Image:Balancing_31.png|framed|none]]
[[Image:Bal_1_TestRun_Save.png|framed|none]]


''Test run''
''Test run''
Line 456: Line 449:
The amplitude scaling of the polar graph is now displayed in unbalance unit <nowiki>[</nowiki>g mm<nowiki>]</nowiki> (blue axis).
The amplitude scaling of the polar graph is now displayed in unbalance unit <nowiki>[</nowiki>g mm<nowiki>]</nowiki> (blue axis).


The blue circle now represents the allowed residual unbalance in <nowiki>[</nowiki>g mm<nowiki>]</nowiki>.
The blue circle now represents the allowed residual unbalance in <nowiki>[</nowiki>g mm<nowiki>]</nowiki> according to the specified class (ISO1940/1).


The result table now shows the results for initial run and test run.
The result table now shows the results for initial run and test run.
Line 464: Line 457:
<u>Example</u>
<u>Example</u>


'''(1)''' </font>Click to save the test run result
'''(1)''' Click to start the calculation


'''(2)''' Click to start the calculation
[[Image:Bal_1_test_Result.png|framed|none]]
 
[[Image:Balancing_32.png|framed|none]]


''Test run results''
''Test run results''
Line 479: Line 470:


'''Orange point '''unbalance with test weight
'''Orange point '''unbalance with test weight
Proceed to the balancing prognosis to study the effect of available balancing weights.


----
----
Line 488: Line 477:
{|border="2" cellspacing="0" cellpadding="4" width="100%"
{|border="2" cellspacing="0" cellpadding="4" width="100%"
|'''(1)''' </font>Select Init run <nowiki>+</nowiki> Test run<br>'''(2)''' Click OK to start the calculation<br>'''(3)''' Result - Unbalance and Phase  
|'''(1)''' </font>Select Init run <nowiki>+</nowiki> Test run<br>'''(2)''' Click OK to start the calculation<br>'''(3)''' Result - Unbalance and Phase  
|'''(4)''' Result - proposal mass and position<br>'''(5)''' Proposal position  
|'''(4)''' Result - proposal mass and position : You need to enter the real mass you will add/remove<br>'''(5)''' Proposal position  


|}
|}


[[Image:Balancing_33.png|framed|none]]
[[Image:Bal_1_imb_calc.png|framed|none]]


''Calculation of balancing weights''
''Calculation of balancing weights''
If the prognostic is in the blue circle, the imbalanced of the rotor will be within the class after the mass correction.


====Balancing prognosis====
====Balancing prognosis====
The effect of balancing weights can now be predicted by the mathematical calculations of the balancing prognosis.
The effect of balancing weights can now be predicted by the mathematical calculations of the balancing prognosis.


Set mass and position of the mass you want to use in column "Mounted Mass".
Set mass and position of the mass you want to use in column "Mounted Mass". The software automatically calculates the expected residual unbalance (green point in polar graph).


Click on "Prognosis" to get the calculation of the expected residual unbalance (green point in polar graph).
In this example, we only had a mass of 5 grams available instead of the calculated 4.685g mass to add at the 7th position. The prognosis shows that the residual unbalance (blue point in polar graph) moves to the green point inside the blue circle.
 
Only a mass of 4.2 gram was available and set to position 7. The prognosis shows that the residual unbalance (blue point in polar graph) moves to the green point inside the blue circle.


{|border="2" cellspacing="0" cellpadding="4" width="100%"
{|border="2" cellspacing="0" cellpadding="4" width="100%"
Line 515: Line 504:
<br>Prognosis<br>
<br>Prognosis<br>


|-
|}
|
====Balancing Run====
* Click "balancing run" (bottom left)
 
* Click "Start" start or F2. The measurement is displayed.
Once you have mounted the test mass as indicated by the software, you can perform a Balancing run, to ensure the rotor is now properly balanced.
* Click "Average", when rotor is at stable speed (Stationary state)
 
|align = "center"|
To do so, Go back in the measurement window and press start.
[[Image:Balancing_37.png|framed|none]]
 
<br>''Balancing run (Black point: Initial run, Orange point: Test run, Dark green point: Balancing run)''
*'''(1)''' Click on average
*'''(2)''' Select "Balancing Run1"
*'''(3)''' Save the measurement


|}
[[Image:Bal_1_BalRun.png|framed|none]]


These points only appear if they are marked "active" in the result window. Then, save the balancing result. At any stage saved results can be reloaded using the "Load Measurement" buttons. They also can be overwritten.
The orange and green point represent the initial and resulting imbalance. These points only appear if they are marked "active" in the result window. Then, save the balancing result. At any stage saved results can be reloaded using the "Load Measurement" buttons. They also can be overwritten.


<u>Example</u>
<u>Example</u>
Line 534: Line 525:
'''(2)''' Click to start the calculation
'''(2)''' Click to start the calculation


[[Image:Balancing_38.png|framed|none]]
[[Image:Bal_1_BalRun_Resut.png|framed|none]]


''Balancing run results''
''Balancing run results''
Line 540: Line 531:
====Balancing report====
====Balancing report====


[[Image:Balancing_39.png|framed|none]]
[[Image:Bal_1_Overview.png|framed|none]]


''Balancing results overview''
''Balancing results overview''<br>


The overview in the following figure now shows the chronological mass predictions and settings as well as the final result ("End").
The overview in the following figure now shows the chronological mass predictions and settings as well as the final result ("End").
Line 550: Line 541:
This overview can be exported into a Microsoft® Editor file (*.txt)''' '''by clicking "Report".
This overview can be exported into a Microsoft® Editor file (*.txt)''' '''by clicking "Report".


[[Image:Balancing_40.png|framed|none]]
[[Image:Bal_1_Report.png|framed|none]]


''Balancing Report''
''Balancing Report''
Line 559: Line 550:


===Measurements, display, storage===
===Measurements, display, storage===
After setting up the acquisition channel and the machine type, you may setup the test run in the "Rotor" window. For two plane balancing, you will need to perform two test run, and set a mass on each plane. By example, here, we are putting a 5g mass at pos. 3 on the first plane for the test run1 and 5g mass at pos. 8 on the second plane for the test run2. We are not putting mass on the second plane for test run1 and no mass on the first plane for test run2 :
[[Image:Bal_2_TestPrep_real.png|framed|none]]<br>
*'''Note :''' You may '''not''' mount the masses at this stage. <br>
Then Press '''Ok''' to reach the measurement window. '''The analyser in now ready for measurement.'''
'''(1)''' </font>Click "Start" start or F2. Measurement is displayed.
'''(1)''' </font>Click "Start" start or F2. Measurement is displayed.


[[Image:Balancing_41.png|framed|none]]
[[Image:Bal_2_Init.png|framed|none]]


''Measurement Display''
''Measurement Display''
Line 567: Line 566:
'''(1)''' </font>Click "Average" when rotor is at stable speed (Stationary state).
'''(1)''' </font>Click "Average" when rotor is at stable speed (Stationary state).


[[Image:Balancing_42.png|framed|none]]
[[Image:Bal_2_Init2.png|framed|none]]


''Measurement Display''
''Measurement Display''
Line 578: Line 577:
'''(2)''' Save your initial measurement
'''(2)''' Save your initial measurement


[[Image:Balancing_43.png|framed|none]]
[[Image:Bal_2_Init3.png|framed|none]]


''Initial run''
''Initial run''


[[Image:Balancing_44.png|framed|none]]
[[Image:Bal_2_Init_Result.png|framed|none]]


''Results of Initial run''
''Results of Initial run''


===Test run 1 and 2===
===Test run 1===
<u>Preparation</u>
<u>Preparation</u>


Line 600: Line 599:
* '''Keep test masses '''after test for example welding or drilling etc.
* '''Keep test masses '''after test for example welding or drilling etc.
* '''Displace two masses per plane '''for machines with slidable balancing weights.
* '''Displace two masses per plane '''for machines with slidable balancing weights.
It shows an example where test mass is to be removed. The test mass of 4.2 grams is set at position 3 ('''2)''' </font>(75°; radius 100 mm) '''(1)'''</font>
It shows an example where test mass is to be removed. The test mass of 5 grams is set at position 3 '''(1)''' </font>(75°; radius 100 mm) '''(2)''' </font>


The settings are saved automatically when closing the window.
The settings are saved automatically when closing the window.


[[Image:Balancing_45.png|framed|none]]
[[Image:Bal_2_Test_PrepRun1.png|framed|none]]


''Test mass positioning for two planes - Test run 1 - Test mass 1 - Plane 1''
''Test mass positioning for two planes - Test run 1 - Test mass 1 - Plane 1''


[[Image:Balancing_46.png|framed|none]]
[[Image:Bal_2_TestRun1.png|framed|none]]


''Test run 1''
''Test run 1''
Line 616: Line 615:
After every test run, don<nowiki>'</nowiki>t forget to remove the test mass '''(3)'''.
After every test run, don<nowiki>'</nowiki>t forget to remove the test mass '''(3)'''.


[[Image:Balancing_47.png|framed|none]]
[[Image:Bal_2_TestRun1Fin.png|framed|none]]


''Remove Test mass 1''
''Remove Test mass 1''


[[Image:Balancing_48.png|framed|none]]
[[Image:Bal_2_TestRun1_Result.png|framed|none]]


''Test run 1 results''
''Test run 1 results''


===Test run 2===
<u>Preparation</u>
<u>Preparation</u>


Line 637: Line 637:
* '''Keep test masses '''after test for example welding or drilling etc.
* '''Keep test masses '''after test for example welding or drilling etc.
* '''Displace two masses per plane '''for machines with slidable balancing weights.
* '''Displace two masses per plane '''for machines with slidable balancing weights.
'''A'''n example is shown where test mass is to be removed. The test mass of 4.2 grams '''(3)''' </font>is set at position 4 (105°; radius 100 mm) '''(4)'''</font>
An example is shown where test mass is to be removed. The test mass of 5 grams '''(4)''' </font>is set at position 8 (225°; radius 100 mm) '''(3)'''</font>


The settings are saved automatically when closing the window.
The settings are saved automatically when closing the window.


[[Image:Balancing_49.png|framed|none]]
[[Image:Bal_2_Rotor_2.png|framed|none]]


''Test mass 2 positioning for two planes - Test run 2 - Test mass 2 - Plane 2''
''Test mass 2 positioning for two planes - Test run 2 - Test mass 2 - Plane 2''<br>


Set the Run number to 2 (1) </font>and save the measurement (2).</font>
You can now perform the measurement of the second test run as previously ( click '''Start/F2''' and '''Average'''). Then, to save the measurement, set the Run number to 2 (1) </font>and save the measurement (2).</font>


[[Image:Balancing_50.png|framed|none]]
[[Image:Bal_2_testRun2_1.png|framed|none]]


''Test run 2''
''Test run 2''


[[Image:Balancing_51.png|framed|none]]
[[Image:Bal_2_TestRun2_Fin.png|framed|none]]


''Remove Test mass 2''
''Remove Test mass 2''
Line 659: Line 659:
'''(1)'''  </font>Results for Plane 1 and Plane 2
'''(1)'''  </font>Results for Plane 1 and Plane 2


'''(2)''' Save the results
'''(2)'''   Click to start the calculation
 
'''(3)'''  Click to start the calculation


[[Image:Balancing_52.png|framed|none]]
[[Image:Bal_2_TestRun2_Result2.png|framed|none]]


''Test run 2 - Result, Save and Start Calculate''
''Test run 2 - Result, Save and Start Calculate''
Line 676: Line 674:
'''(2)''' Click OK to start the calculation
'''(2)''' Click OK to start the calculation


[[Image:Balancing_53.png|framed|none]]
[[Image:Bal_2_imbal_Calc.png|framed|none]]


''Test run 2''
''Test run 2''
Line 704: Line 702:
'''(6)'''  Proposal mass and position Plane 2
'''(6)'''  Proposal mass and position Plane 2


[[Image:Balancing_54.png|framed|none]]
[[Image:Bal_2_imbal_Calc_2.png|framed|none]]


''Test run results''
''Test run results''
Line 715: Line 713:
Click on "Prognosis" to get the calculation of the expected residual unbalance (green point in polar graph).
Click on "Prognosis" to get the calculation of the expected residual unbalance (green point in polar graph).


Only a mass of 4.2 grams was available, and set to position 7. The prognosis shows that the residual unbalance (blue point in polar graph) moves to the green point inside the blue circle.
Masses of 1 and 3.5 grams were available, and set to positions 5 and 6 on the first plane, and calculated masses are too small for the second plane. Therefore, we don't mount masses on the second plane as it is already balanced. <br>
 
The prognosis shows that the residual unbalance (light green point in polar graph) moves inside the blue circle.


[[Image:Balancing_55.png|framed|none]]
[[Image:Bal_2_MountedMass.png|framed|none]]


''Prognosis''
''Prognosis''
Line 723: Line 723:
<u>Execution:</u>
<u>Execution:</u>


* Click "balancing run" (bottom left)
* Click "Online balancing" (bottom left)
*  Click "Start" start or F2.  Measurement is displayed.
*  Click "Start" start or F2.  Measurement is displayed.
* Click  "Average", when rotor is at stable speed .(Stationary state)
* Click  "Average", when rotor is at stable speed .(Stationary state)
Line 742: Line 742:
(These points only appear if they are marked "active" in the result window)
(These points only appear if they are marked "active" in the result window)


Save the balancing result.
To save the balancing result, go back in the standard window by clicking on '''"Standard"''' and save as usual.
 
At any stage saved results can be reloaded using the "Load Measurement" buttons.


[[Image:Balancing_56.png|framed|none]]
[[Image:Bal_2_onlineBal.png|framed|none]]


''Balancing run''
''Balancing run''
Line 757: Line 755:
* Click "Report" in''' '''to''' '''export this table into a Microsoft® Editor file (*.txt).
* Click "Report" in''' '''to''' '''export this table into a Microsoft® Editor file (*.txt).


[[Image:Balancing_57.png|framed|none]]
[[Image:Bal_2_FinalResult.png|framed|none]]


''Balancing run results''
''Balancing run results''
Line 765: Line 763:
====Balancing report====
====Balancing report====


[[Image:Balancing_58.png|framed|none]]
[[Image:Bal_2_Overview.png|framed|none]]


''Balancing results overview''
''Balancing results overview''
Line 777: Line 775:
This overview can be exported into a Microsoft® Editor file (*.txt) as a Balancing Report.
This overview can be exported into a Microsoft® Editor file (*.txt) as a Balancing Report.


[[Image:Balancing_59.png|framed|none]]
[[Image:Bal_2_Report.png|framed|none]]


''Balancing Report''
''Balancing Report''


[[Image:Balancing_60.png|framed|none]]
[[Image:Bal_2_Before_After.png|framed|none]]


''Unbalance before  [[Image:Balancing_61.png]] and after [[Image:Balancing_62.png]]balancing''
''Unbalance before  [[Image:Balancing_61.png]] and after [[Image:Balancing_62.png]]balancing''


[[Image:Balancing_63.png|framed|none]]
[[Image:Bal_2_Before_After_2.png|framed|none]]


''Vibration measurement before [[Image:Balancing_64.png]]and after [[Image:Balancing_65.png]]balancing''
''Vibration measurement before [[Image:Balancing_64.png]]and after [[Image:Balancing_65.png]]balancing''